• 제목/요약/키워드: Floating Building

검색결과 129건 처리시간 0.029초

저진동 궤도슬래브의 설계와 시공 (Design and Construction of Floating Slab Track)

  • 이은호;김용재;박명균
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.214-219
    • /
    • 2008
  • Recently, railway has been pointed to the efficiency of transportation, rapid transit, and comfortable train ride. In the case of domestic situation, both rapid transit railway and existing railway have been operated in higher speed and the construction of railway near the city building has been increased as well. Because of the rapid transit system and heavy railway, the noise and vibration of railway has been increased so that the strong standards in terms of environmental matter should be required. Therefore, the solution to avoid environmental matters becomes one of the most important factor in constructing railway. In this study, floating slab system which is one of the solution to avoid noise and vibration in railway has been introduced, and the foreign technology and the trend of this business has been investigated. In addition, the method of conceptual design and construction of floating slab system according to the isolator has been introduced.

  • PDF

방진재 위치에 따른 플로팅 슬래브 궤도의 정적거동분석 (Analysis of floating Slab Track about Arrangement of Reduction Material of Vibration)

  • 김용재;박성재;전종수;박명균;이두화;박만호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집 특별세미나,특별/일반세션
    • /
    • pp.659-662
    • /
    • 2009
  • Railway has been pointed to the efficiency of transportation, rapid transit, and comfortable train ride. the construction of railway near the downtown area and station building are increasing for maximization of utilization and convenience. but the heavy of transportation and rapid transit lead to increase noise and vibration. the noise and vibration of railway may cause the civil appeal, decline in the serviceability and insufficiency of environmental standard. In this study, floating slab system which is one of the solution to avoid noise and vibration in railway has been introduced, and analyzed floating Slab Track into arrangement of reduction material of vibration. As a result of analysis, It was estimated the bearing installation though slab have not a negative factor and terminal arrangement of reduction material of vibration have advantage for static behavior.

  • PDF

마르코브 체인을 적용한 유동인구의 매출 및 이동 패턴 분석 (Analyzing Patterns of Sales and Floating Population Using Markov Chain)

  • 김봉균;이원상;이봉규
    • 인터넷정보학회논문지
    • /
    • 제21권1호
    • /
    • pp.71-78
    • /
    • 2020
  • 최근, 젠트리피케이션 현상으로 인하여 도심 내 지역 경제와 커뮤니티 형성에 필수적인 역할을 하는 지역 상권에 대한 체계적인 분석과 이해의 중요성이 커지고 있다. 본 연구에서는 지역 상권에 대한 체계적인 분석과 이해를 위한 방법론을 소개하고 실증적인 사례를 제시하고자 한다. 본 논문에서는 서울의 대표적인 지역상권인 가로수길과 가구거리의 유동인구를 이동통신 기지국 데이터를 통해 추적하고, 유동인구의 매출 패턴과 이동 흐름의 패턴을 파악하였다. 또한, 이동통신사의 기지국 기반 유동인구 데이터에 마르코브 체인을 적용하여 지역 상권 이해의 중요한 요소인 유동인구 흐름을 보다 체계적으로 이해하고자 하였다. 이와 같은 유동인구 흐름에 대한 분석 결과를 바탕으로, 본 논문에서는 상권 내 매출 정보와 결합되어 지역상권의 진화에 대한 시사점을 제공하고자 한다. 궁극적으로 본 연구의 결과가 젠트리피케이션 등에 의해 침체되는 지역 상권의 활성화를 촉진하고 더 나아가 도심 경제의 균형잡힌 성장에 기여할 것으로 기대한다.

플로팅 건축물의 시장현황과 산업동향 (An Analysis of Market Situation and Industry Trend in Floating Architecture)

  • 이한석;문창호;강영훈
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2009년도 추계학술대회
    • /
    • pp.141-144
    • /
    • 2009
  • 우리나라는 국토 면적에 비해 해안선이 길어 해양공간 및 연안지역의 개발 잠재력이 높으며 플로팅 건축물의 활용 가능성이 매우 크다. 또한 세계 최고 수준의 조선 및 건축기술을 가지고 있어 플로팅 건축물 관련 설계 및 시공기술을 체계적으로 확립한다면 국내 외시장에서 충분히 경쟁력을 갖출 수 있는 여건이 마련되어 있다. 본 연구는 플로팅 건축물의 본격적인 기술개발에 앞서 국내외 시장현황을 살펴보고 관련 산업동향을 파악하여 플로팅 건축물의 기술개발 및 산업화률 위한 기초자료를 확보하는데 그 목적이 있다.

  • PDF

동결융해 환경에 노출된 타일 모듈의 부착강도 특성 (Adhesion Strength Properties of Tile Modules Exposed to Freeze-Thaw Environment)

  • 편수정;김규용;최병철;김문규;유하민;남정수
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 봄 학술논문 발표대회
    • /
    • pp.217-218
    • /
    • 2023
  • In modern architecture, tiles are used as a decorative material to enhance the appearance of buildings. However, defects occurring during tile installation affect not only the appearance of the building, but also its maintenance. This study aims to investigate stable tile installation by producing tile modules using the floating mortar method and conducting freeze-thaw tests to measure their adhesion strength. Test results showed that the adhesion strength increased as the mesh size decreased, except for S3 mesh. This study highlights the importance of research on tile installation to solve problems related to building appearance and maintenance.

  • PDF

교육시설의 공기환경 실측에 관한 연구 (A Study on the Measurement of Indoor Air Pollutants in High School Building)

  • 김선정;김병수
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.1392-1397
    • /
    • 2008
  • This study is to measure the change of the $CO_2$ and floating dust concentration depending on the volume of the ventilation and the state of on/off the ventilation for the estimation of the air pollution in classroom. The results could be summarized as follows: the test cell was the two full scaled model and the one is set up with ventilation system another was not. the volume of classroom is 170.1m3 and the number of persons are 35. 1)when the ventilation system was not installed, The experimental results of the $CO_2$ concentration showed the average of 2,150ppm and the maximum of 2,740ppm in the classroom. This was the higher than 1,000ppm, the standard value of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development, 1000ppm. The $CO_2$ concentration was relatively increasing during school hours. 3)In case of the volume of ventilation of $800m^3$/h, the $CO_2$ concentration of classroom showed the average of 962 ppm and the maximum of 1,380 ppm. This was higher than 1,000ppm, the standard of ASHRAE and the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 4)The floating dust(PM10) was the maximum of 0.52 mg/$m^3$, the minimum of 0.25 mg/$m^3$, and the average of 0.32 mg/$m^3$ in case of the ventilation system off. Those were higher than the standard value 0.15 mg/$m^3$. In case of the ventilation system on, the floating dust(PM10) was the maximum of 0.174 mg/$m^3$ , the minimum of 0.048 mg/$m^3$, and the average of 0.078 mg/$m^3$. These were the lower than 0.15 mg/$m^3$, the standard of the enforcement regulations of School Sanitation Code in Ministry of Education & Human Resources Development. 5)The concentrations of $CO_2$ and PM10 were largely depending on the number of students and the ventilation system, The installation of the ventilation system is necessary for the amenity environment and the management of the indoor air quality.

  • PDF

콘크리트-PE 부유체 모듈의 케이싱형 전단키 구조성능 실험평가 (Experimental Evaluation on Structural Analysis of the Shear Key between Concrete-PE Modules)

  • 김정수;정연주
    • 한국재난정보학회 논문집
    • /
    • 제19권3호
    • /
    • pp.545-553
    • /
    • 2023
  • 연구목적: 본 연구는 콘크리트와 PE(Poly Ethylene)로 구성된 부유식 방파제 모듈 간 결합을 위해 케이싱형 전단키를 제안하고 구조성능을 평가하였다. 연구방법: Eurocode에 준거하여 전단키 유형별로 극한 하중 실험을 수행하였다. 연구결과: 케이싱형 전단키가 무근 콘크리트 최대 전단 저항력을 개선(무근 전단키 대비 1.5배)하는 효과를 보였으며, 철근 콘크리트 전단키 대비 최대 전단 저항력 이후의 연성 거동을 증가시키는 효과를 나타냈다. 결론: 제안된 케이싱형 전단키의 활용을 통해 모듈형 구조체 간 전단 연결 안전성을 향상할 수 있을 것으로 판단된다.

완충재의 시공결함과 경량충격음 편차에 관한 사례 연구 (A Case Study of the Relationship between the Defects of resilient materials and the deviation of Light-weight Floor Impact Noise)

  • 성요한;김진식;김혜원;조성준
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.137-138
    • /
    • 2023
  • The floating floor is a structure which introduced to reduce the noise of apartment houses. This structure can decrease vibration energy through resilient materials. However, it is limited to completely construct resilient materials in South Korea due to floor heating structure and other reasons. And It is a controversial issue how well the resilient materials should be constructed to prevent floor impact noise. These resilient defect areas are typically found in wall corners, door sills, hot water dispenser in kitchen and areas where thermal insulation is attached. This study investigates the acoustical effect of the defect areas in two ways. First, it is analyzed by several assumption conditions and calculated how much deviation would occur. Then we researched the deviation of the 76 field test data about light-weight floor impact noise. This study could be useful for a constructor to determine how much should minimize resilient materials defect areas.

  • PDF

부유식 태양광 발전기의 패널과 부유체에 작용하는 풍하중과 유동특성 (Flow Characteristics and Wind Loads on the Solar Panel and Floating System of Floating Solar Generato)

  • 유대겸;이계복
    • 한국산학기술학회논문지
    • /
    • 제20권10호
    • /
    • pp.229-235
    • /
    • 2019
  • 지구 환경문제와 자원 고갈에 따른 에너지 위기로 인해 화석 연료를 사용하지 않아 이산화탄소와 같은 온실가스 배출이 없는 청정 에너지원으로서 신재생 에너지는 중요성이 강조되고 있다. 부유식 태양광발전은 기존의 태양광 발전기술과 플로팅 기술을 융합한 신개념의 발전 방식이다. 종래의 육상이나, 건축물이 아닌 유휴수면에 설치하는 재생에너지원으로 구조체, 계류장치, 태양광 발전설비, 수중케이블 등으로 구성된다. 또한 단위모듈 형태로 설계되어 발전용량에 따라 단위모듈을 서로 연결하여 대규모 발전 시설을 조성할 수 있다. 태양광 발전기는 옥외에 설치되기 때문에 구조물에 대한 풍하중의 영향이 매우 크다. 본 연구에서는 부유식 태양광 발전 구조물에 큰 영향을 주는 풍하중을 전산유체역학을 통해 해석하였다. 유동 특성과 풍하중에 대한 풍향과 경사각의 영향을 분석하였다. 모듈의 개수와 바람의 방향에 따라 최대 하중을 받는 위치와 크기 그리고 태양광 패널과 부유체 주위의 유동 특성을 구하였다. 태양광 패널의 지면에 대한 경사각이 클수록 풍하중은 증가하였다.

부유식 해상구조물의 계류를 위한 사질토 지반의 석션파일 설계 (Design for Installation of Suction Piles in Sand Deposits for Mooring of Floating Offshore Structures)

  • 박철수;이주형;백두현;도진웅
    • 한국지반공학회논문집
    • /
    • 제30권10호
    • /
    • pp.33-44
    • /
    • 2014
  • 본 연구에서는 국내 서남해 해상지역 시범사업의 부유식 콘크리트 해상구조물 계류를 위한 기초시스템으로서 석션파일을 적용하기 위한 예비설계를 수행하였다. 설계에 앞서 시범사업 대상지역인 서남해안에 대한 지반 및 수리 조건, 재현주기 100년의 환경외력 등 현장 조건을 면밀히 검토하였다. 석션파일은 설계하중에 대한 수평방향 지지력을 만족해야하고, 뿐만 아니라 지반종류 및 강도정수, 유효응력, 침투압 등의 조건에 따른 관입성 검토가 수행되어야 한다. 본 설계에서는 석션파일 직경에 따라 설계외력에 대해 수평방향 안정성을 확보할 수 있는 목표 침설깊이를 설정하고, 침설단계별로 상한석션압 이내에서 관입력과 관입저항력 비교를 통해 설계석션압을 산정하였다. 검토결과 직경 3.0~5.0m 석션파일의 경우 목표 깊이까지 침설이 불가능하였고, 직경 6.0m와 7.0m 석션파일은 각각 침설깊이 8.5m와 8.0m에서 수평방향 안정성 및 설계석션압에 의한 침설을 모두 만족함을 확인하였다.