• Title/Summary/Keyword: Flexible denture

Search Result 17, Processing Time 0.022 seconds

Improvement of Articulation Disorder Using Flexible Partial Denture in Intellectural Disability Patient with Missing Lower Incisors (하악 전치부 상실로 인한 조음장애를 보이는 경도 지적장애 환아에서 탄성의치를 통한 조음능력의 향상)

  • Choi, Haein;Choi, Byungjai;Choi, Hyungjun;Song, Jeseon;Lee, Jaeho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.40 no.4
    • /
    • pp.306-313
    • /
    • 2013
  • Speech is complex psycho-physiological mutual process which includes many orofacial organs. Especially, teeth play an especially important role as an articulation organ in conjunction with the lips and tongue. When teeth are missing, the position of tongue and mandible is adjusted to produce correct sound. If a patient's adaptive function is inadequate for modification of malocclusion, prosthodontic and orthodontic interventions are necessary. Missing teeth of young patients should be reconstructed bacause it can cause malocclusion, decreased masticatory efficiency, articulation disorders, esthetic problem, and temporomandibular disorder. Valplast$^{(R)}$(Valplast International Corp, New York, USA) flexible denture is useful for rehabilitation due to its excellent physical properties, esthetics, and small volume. This case is regardingan intellecturally disabled patient with anarticulation disorder caused by missing lower incisors due to trauma. The patient showed improvement in articulation by using flexible partial denture. The purpose of this report is to figure out the influence of missing lower anterior teeth on articulation.

THE EFFECT OF DENTURE CLEANSERS ON SOFT LINING MATERIALS (의치 세정제가 탄성 의치상 이장재에 미치는 효과에 관한 연구)

  • Jang, Bok-Sook;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.31 no.2
    • /
    • pp.219-235
    • /
    • 1993
  • To determine the compatibilities of soft liming materials with denture cleansers by measuring the flexibility and elasticity and investigating the surface changes, 4 self-curing acrylic resin soft lining materials and 1 heat-curing silicone soft lining material were evaluated. 3mm thick x 20mm diameter discs of soft lining materials were individually bonded to a hard acrylic resin base as per manufacturers’instructions. Using an Instron universal testing machine, a static stress of $2kg/cm^2$ was applied for 30secs., the strain in compression was measured, giving an indication of the material’s flexibility. Elastic recovery was measured at 10secs. After removal of stress. Surface changes were investigated with Stereomicroscope. Then the specimens were immersed in 4alkaline peroxide denture cleansers and water as control group, tests were carried out at 1 day, 2 days, 7 days, 14 days and 30 days. The results were as follows : 1. Alkaline peroxide denture cleansers caused considerable porosity on the surface of selfcuring acrylic resin soft lining materials, and the most affected by the cleansers were Viscogel, Coe-Soft, Coe-Comfort, Lynal, in that order. 2. There was significant difference in flexibility between each soft lining material except for Coe-Comfort and Visco-gel, and every soft lining material was significant difference in elasticity. Especially Molloplast-B and Lynal were less flexible and more elastic than other soft lining materials(p<0.05). 3. The denture cleansers increased the flexibility and elasticity of the soft lining materials compared with control group(p<0.05), and Denalan, Polident, Kleenite, Efferdent affected the soft lining materials in that order. 4. There was significant difference in flexibility between each denture cleanser except for Denalan and Polident(p<0.05). Though Denalan and Polident, Denalan and Kleenite did not show significant difference in elasticity, other denture cleansers showed significant difference among each other(p<0.05). 5. Clinically Coe-Comfort, Coe-Soft and Visco-gel were incompatible with alkaline peroxide denture cleansers, and Lynal would be used within only 2 weeks. But Molloplast-B was compatible with alkaline peroxide denture cleansers.

  • PDF

Photoelastic stress analysis of the mandibular unilateral free-end removable partial dentures according to the design (하악 편측 유리단 가철성 국소의치의 설계에 따른 광탄성 응력 분석)

  • Park, Cheol-Woo;Kay, Kee-Sung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.47 no.2
    • /
    • pp.206-214
    • /
    • 2009
  • Statement of problem: There are common clinical cases in which the mandibular first and second molars are missing unilaterally. Purpose: This study was designed to compare and evaluate the magnitude and distribution of stress produced by four kinds of mandibular unilateral free-end removable partial dentures that could be applied clinically in Kennedy class II cases. Material and methods: Four unilateral free-end removable partial dentures using clasp, Konus crown, resilient attachment, and flexible resin were fabricated on the photoelastic models of the Kennedy class II cases. The vertical load of 6㎏ was applied on the central fossa of the first molar of every removable partial denture in the stress freezing furnace and the photoelastic models were frozen according to the stress freezing cycle. After these models were sliced mesio-distally to a thickness of 6mm, the photoelastic isochromatic white and black lines of the sliced specimens were examined with the transparent photoelastic experiment device and photographs were taken with a digital camera. The fringe order numbers at eight measuring points in the photograph were measured with the naked eye. Results: The maximum fringe order number of each sliced specimen and the fringe order number at the residual ridge just below the loading point were in the decreasing order of the unilateral removable partial dentures using flexible resin followed by clasp, resilient attachment, and Konus crown. The fringe order number at the root apex of the second premolar was in the decreasing order of the unilateral removable partial dentures using clasp followed by flexible resin, Konus crown, and resilient attachment. Conclusion: The removable partial denture using Konus crown showed the most equalized stress distribution to the supporting alveolar bone of abutment teeth and residual ridge under the vertical loads. The removable partial denture using flexible resin can be applied to the case that has a better state of residual ridge than abutment teeth.

Fabrication of palatal lift prosthesis using thermoplastic resin for a patient with velopharyngeal insufficiency (구개인두부전증 환자에서 열가소성레진을 이용해 연구개거상장치를 제작한 증례)

  • Jung, Hyun Jung;Kim, Jee Hwan;Lee, Sang-Hwy;Park, Young-Bum
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.3
    • /
    • pp.286-290
    • /
    • 2016
  • Recently, flexible removable prosthesis with thermoplastic resin clasp has increasingly become popular. In comparison with conventionally used acrylic resin, thermoplastic resin has lower flexural strength and elastic modulus. Thus, flexible removable prosthesis has low risk of fracture, so denture base can be made thin and light, increasing patient comfort. Also, it can passively sit at tooth undercut during rest, so abutment teeth need minimum or no preparation. In this case report, a 44 year old female patient with mild velopharyngeal insufficiency was treated with a palatal lift prosthesis made of polyester thermoplastic resin. Since the patient had no missing tooth and desired conservative treatment, the flexible removable prosthesis provided relatively satisfactory results.

FINITE ELEMENT ANALYSIS OF STRESSES AND DEFLECTIONS INDUCED BY FIXED PARTIAL DENTURE USING ENDOSTEAL IMPLANT (골내 임프란트를 이용한 고정성 국소의치 하에서 변위 및 응력에 관한 유한요소법적 분석)

  • Choi, Su-Ho;Chung, Chae-Heon
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.233-248
    • /
    • 1991
  • The purpose of this study was to qunatatively analyze the stress patterns induced in the abutment, superstructure, supporting bone and to determine the deflection of abutment and superstructure by appling occlusal force to natural teeth supported fixed prostheses and implant-supported fixed prostheses. The analysis has been conducted by using the two dimensional finite element method. The implant and natural tooth-supported bridge has a first molar pontic supported by mandibular second bicuspid and implant posterior retainer, which were rigidly(Model A) or flexible(Model B). The natural teeth-supported bridge has a first molar pontic supported by mandibular second bicuspid and second molar, which were rigidly splinted together(Model C). 63.5kg(Load P1) of localized load on central fossa of first molar pontic and 24kg(Load P2) of distributed load on each occlusal surface were applied respectively. 1. The coronal portion of premolar pontic and posterior abutment in fixed partial denture deflected inferiorly in order of Model B, Model C and Model A under Load P1 and Load P2. 2. Mesial displacement of the coronal portion of premolar showed in Model A, Model B and Model C under Load P1, but mesial displacement of that in Model B and distal displacement of that in Model A and Model C showed under Load P2. 3. Mesial displacement of the coronal portion of the pontic and distal displacement of the coronal portion of posterior abutment showed in Model A, Model B and Model C under Load P1 and Load P2. Displacement in the case of Model B was greater than that of Model A and Model C. 4. In the case Model A under Load P1 and Load P2, high stress apically was concentrated in the mesiocervical portion of the posterior abutment than in the disto-cervical portion of the premolar. 5. In the case of Model B under Load P1 and Load P2 high stress was concentrated in the case of the premolar than in that of posterior abutment and high stress especially was concentrated in the connected portion of pontic and posterior abutment. 6. In the case of Model C under Load P1 and Load P2, high stress was concentrated in the distal area of the cornal portion of premolar and the mesial area of the coronal portion of posterior abutment, and stress pattern was anteroposterially symmetric around the pontic. 7. Load P1 and Load P2 compared, stress magnitude was different but stress pattern was similar in Model A, Model B and Model C. 8. Under Load P1 and P2, stress magnitude in the mesial distal portion and the portion of root apex of the posterior abutment was in order of Model B, Model A and Model C.

  • PDF

Surface roughness and $Candida$ $albicans$ adhesion to flexible denture base according to various polishing methods (연마방법에 따른 탄성의치의 표면거칠기와 $Candida$ $albicans$의 부착율 변화)

  • Oh, Ju-Won;Seo, Jae-Min;Ahn, Seung-Keun;Park, Ju-Mi;Kang, Cheol-Kyun;Song, Kwang-Yeob
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.50 no.2
    • /
    • pp.106-111
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the effect of 3 chairside polishing methods and laboratory polishing methods on surface roughness and $C.$ $albicans$ adhesion of polyamide denture base. Materials and methods: Using contact profilometer, the surface of polyamide specimens ($25{\times}15{\times}2mm$) was studied after conventional polishing without finishing and after chiarside polishing with 2 chiarside polishing kits and chairside-pumice polishing following finishing with tungsten carbide bur. To evaluate the adhesion of $C.$ $albicans$, $C.$ $albicans$ suspension was overlayed on the test specimen. And the specimens were incubated for 2 hours. Imprint culture method was achieved and counted the colony on the agar plate. Polished polyamide were evaluated using a scanning electron microscope. The statistics were conducted using one-way ANOVA and in case of difference, Scheffe test and Tamhane's T2 test were used. Results: Surface roughness (Ra) of surfaces polished with 2 chairside polishing kits had higher than conventional polishing and pumice polishing. The highest roughness value was $0.32{\pm}0.10{\mu}m$, and the lowest was $0.02{\pm}0.00{\mu}m$. The adhesion of $C.$ $albicans$ on the specimens polished with chairside polishing group and pumice polishing group were increased than conventional polishing group ($P$<.01). Conclusion: Conventional laboratory polishing was found to produce the smoothest surface and the lowest adhesion of $C.$ $albicans$. Two groups polished with Chairside polishing kits were similar with respect to surface roughness. Surface of the specimen polished with pumice is significantly smoother than 2 chairside polishing groups, but the result of $C.$ $albicans$ adhesion is that group polished with pumice was similar with 2 chairside polishing groups ($P$>.01).

A Case of Radiolucent Foreign Body (Temporary Resin Bridge) Aspiration Accompanied by Inflammatory Polyps (방사선 투과성 이물 흡인(Temporary Resin Bridge)에 의한 염증성 용종 1예)

  • Moon, Seol Kyung;Lee, Ji Myoung;Jeong, Hae Bin;Song, Joo Yong;Kim, Sung Kyoung;Lee, Sang Haak;Yoon, Hyeong Kyu;Lee, Sook Young;Kim, Seok Chan;Moon, Hwa Sik
    • Tuberculosis and Respiratory Diseases
    • /
    • v.64 no.6
    • /
    • pp.456-459
    • /
    • 2008
  • This case demonstrates the rare occurrence of a radiolucent temporary resin bridge aspiration in adults while they are in a conscious and awaken state and the resultant formation of inflammatory polyps. Although no unique findings were noted in a chest x-ray, careful history taking accompanied by physical examinations can lead to clinical suspicion of foreign body aspiration in an earlier stage. Moreover, flexible bronchoscopy is a tool useful not only for the evaluation process but also for managing the aspirated foreign material.