• Title/Summary/Keyword: Flexible Flow Sensor

Search Result 15, Processing Time 0.02 seconds

Wireless Telemetry of an Oscillating Flow using Mesoscale Flexible Cantilever Sensor (메소스케일 유연 외팔보 센서를 이용한 진동유동의 무선 계측)

  • Park, Byung Kyu;Lee, Joon Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.37 no.5
    • /
    • pp.495-501
    • /
    • 2013
  • This paper describes a flexible wireless telemetering system using a mesoscale cantilever sensor, which is microfabricated with a patterned thin Ni-Cu foil on a resin substrate. The dynamic validation of the sensor has been conducted in a flow. The wireless telemetry is used to obtain data regarding the oscillating flows. It is shown that the sensor is nearly independent of the environmental temperature and is suitable for application to primary healthcare and diagnostic devices. It can be easily integrated with other modules for measuring physiological parameters, e.g., blood pressure, oxygen saturation, and heart rate, to increase the convenience and reliability of diagnosis. The precision and reliability of the sensor are also dependent on the design of the analog front-end and noise reduction techniques. It is shown that the present system's minimum interval between packet transmissions is ~16 ms.

An embedded vision system based on an analog VLSI Optical Flow vision sensor

  • Becanovic, Vlatako;Matsuo, Takayuki;Stocker, Alan A.
    • Proceedings of the Korea Society of Information Technology Applications Conference
    • /
    • 2005.11a
    • /
    • pp.285-288
    • /
    • 2005
  • We propose a novel programmable miniature vision module based on a custom designed analog VLSI (aVLSI) chip. The vision module consists of the optical flow vision sensor embedded with commercial off-the-shelves digital hardware; in our case is the Intel XScale PXA270 processor enforced with a programmable gate array device. The aVLSI sensor provides gray-scale imager data as well as smooth optical flow estimates, thus each pixel gives a triplet of information that can be continuously read out as three independent images. The particular computational architecture of the custom designed sensor, which is fully parallel and also analog, allows for efficient real-time estimations of the smooth optical flow. The Intel XScale PXA270 controls the sensor read-out and furthermore allows, together with the programmable gate array, for additional higher level processing of the intensity image and optical flow data. It also provides the necessary standard interface such that the module can be easily programmed and integrated into different vision systems, or even form a complete stand-alone vision system itself. The low power consumption, small size and flexible interface of the proposed vision module suggests that it could be particularly well suited as a vision system in an autonomous robotics platform and especially well suited for educational projects in the robotic sciences.

  • PDF

Development of Three-ring Conductance Sensor based on Flexible Printed Circuit Board for Measuring Liquid Film thickness in Two-phase Flow with High Resolution (고정밀 2상유동 액막두께 측정을 위한 연성회로기판 기반 3-전극 센서 개발)

  • Lee, Kyu-Byoung;Kim, Jong-Rok;Euh, Dong-Jin;Park, Goon-Cherl;Cho, Hyoung Kyu
    • Journal of Sensor Science and Technology
    • /
    • v.25 no.1
    • /
    • pp.57-64
    • /
    • 2016
  • To understand a two-phase flow, a liquid film thickness is one of the important factors. A lot of researches have been performed to measure liquid film thickness with various approaches. Recently, an electrical conductance method which uses the conductivity of the liquid film has been widely applied on measuring the liquid film thickness. Though the electrical method has an advantage in high spatial resolution, as the conductivity of liquid can be affected by its temperature variation, the conventional electrical conductance methods have a limitation in being applied on varying temperature conditions where a heat transfer is involved. The purpose of this study is to develop a three-ring liquid film sensor that overcomes the limitation of the conventional method. The three-ring conductance method can measure the film thickness regardless of temperature variation by compensating the change of liquid conductivity. Considering its application on a wide range of conditions such as high temperature or curved surfaces, the sensor was fabricated on flexible printed circuit board (FPCB) in this study. This paper presents the concept of the measurement method, design procedure, prototype sensor fabrication and calibration results.

Research and development of Hyundai FFVs(flexible fuel vehicles) (현대 FFV(Flexible Fuel Vehicle) 개발)

  • 명차리;이시훈;박광서;박심수
    • Journal of the korean Society of Automotive Engineers
    • /
    • v.14 no.6
    • /
    • pp.67-73
    • /
    • 1992
  • This paper describes Hyundai's research and development work on a flexible fuel vehicle (FFV). The work on FFV has been conducted to evaluate its potential as an alternative to the conventional gasoline vehicle. Hyundai FFV described here can be operated on M85, gasoline, or any of their combinations, in which the methanol concentration is measured by an electrostatic type fuel sensor. For that operation, a special FFV ECU(Eletronic Control Unit) has been developed and incorporated in the FFV. The characteristics affecting FFV operation, such as FFV ECU control strategy and injector flow rate, have been investigated and optimized through the experiment. And various development tests have been performed in view of engine performance, durability, cold startability, and exhaust emissions reduction. The exhaust gas aftertreatment system consisting of manifold type catalyst and secondary air injection system shows good emission reduction performance including formaldehyde, and finally, the possibility of the FFVs as the low emission vehicles is evaluated by presenting NMOG(Non-Methane Organic Gases) levels with respect to M0 and M85. With these results, it is concluded that FFV can be a candidate for the low emission vehicles, but more works on its durability improvement is required.

  • PDF

Stability analysis for a dissipative feedback control law

  • Kang, Sung-Kwon
    • Journal of the Korean Mathematical Society
    • /
    • v.32 no.4
    • /
    • pp.869-876
    • /
    • 1995
  • Piezo devices such as piezoceramic patches knwon as collocated rate sensor and actuators are commonly used in control of flexible structure (see, e.g., [1]) and noise reduction. Recently, Ito and Kang ([4]) developed a nonlinear feedback control synthesis for regulating fluid flow using these devices.

  • PDF

Electrical Properties and Reliability of the Photo-conductive CdS Thin Films for Flexible Opto-electronic Device Applications (유연성 광전도 CdS 박막의 증착조건에 따른 전기적 특성 및 신뢰성 평가 연구)

  • Hur, Sung-Gi;Cho, Hyun-Jin;Park, Kyoung-Woo;Ahn, Jun-Ku;Yoon, Soon-Gil
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.22 no.12
    • /
    • pp.1023-1027
    • /
    • 2009
  • Cadmium sulfide (CdS) thin film for flexible optical device applications were prepared at $H_2/(Ar+H_2)$ flow ratios on polyethersulfon (PES) flexible polymer substrates at room temperature by radio frequency magnetron sputtering technique. The CdS thin films deposited at room temperature showed a (002) preferred orientation and the smooth surface morphologies. Films deposited at a hydrogen flow ratio of 25% exhibited a photo- and dark-sheet resistance of about 50 and $2.7\;{\times}\;10^5\;{\Omega}/square$, respectively. From the result of the bending test, CdS films exhibit a strong adhesion with the PES polymer substrates and the $Al_2O_3$ passivation layer deposited on the CdS films only shows an increase of the resistance of 8.4% after exposure for 120 h in air atmosphere.

Fabrication of Biofuel Cell Roll Using Flexible CNT Nanosheet Substrate (유연한 CNT Nanosheet 기판을 이용한 생체연료전지 Roll 제작)

  • Sung, Jungwoo;Lim, Geunbae
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.6
    • /
    • pp.388-391
    • /
    • 2014
  • The most promising application of the biofuel cells is implantable devices, so the biofuel cells should have an appropriate shape for the vascular vessel. We demonstrated the biofuel cell roll for using in tubes. MWNTs were aggregated by vacuum filtration on a nitrocellulose membrane filter, which was biocompatible and flexible. The MWNT aggregated nitrocellulose membrane used the electrodes of the biofuel cells because it was conductive as well as nanostuructured. Then, the membrane was rolled into the roll shape. The maximum power density of the biofuel cell roll was $7.9{\mu}W/cm^2$ at 153mV and 50 mM glucose. Also, the power density is expected to increase in its practical application if there is flow in the tube, which makes the transportation of fuel easy. The biofuel cell roll contacts with the wall of the tube, so flow in the tube does not disturb. Also, the biofuel cell roll has multi-layers offering more electroactive area.

Performance Improvement of Peristaltic Micropump Using Various Actuating Signal (다양한 동작신호의 사용에 따른 연동형 마이크로 펌프의 성능 향상)

  • Hong, Pyo-Hwan;Jung, Dong-Geon;Pyo, Dae-Seong;Lee, Jong-Hyun;Cho, Chan-Seob;Kim, Bonghwan
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.428-432
    • /
    • 2013
  • This paper described the development of electrostatically driven peristaltic micropump. The proposed micropump consists of a flexible membrane and a single chamber which electrodes are inserted. The single chamber is divided into smaller cells by the electrodes. The fabricated micropump was operated with four electrodes in the membrane and a various phase sequencing actuation. We studied the changes in the flow rate corresponding to the actuating signal applied to the micropump under the zero hydraulic pressure difference between lnlet port and outlet port. The pump was operated from 60 to 130 V. Whereas the maximum flow rate in basic actuating signal is about 83 ${\mu}1/min$ at 15 Hz, the maximum flow rate in optimized actuating signal is about 114 ${\mu}l/min$ at 10 Hz.

A Study on Ceiling Light and Guided Line based Moving Detection Estimation Algorithm using Multi-Camera in Factory

  • Kim, Ki Rhyoung;Lee, Kang Hun;Cho, Su Hyung
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.4
    • /
    • pp.70-74
    • /
    • 2018
  • In order to ensure the flow of goods available and more flexible, reduce labor costs, many factories and industrial zones around the world are gradually moving to use automated solutions. One of them is to use Automated guided vehicles (AGV). Currently, there are a line tracing method as an AGV operating method, and a method of estimating the current position of the AGV and matching with a factory map and knowing the moving direction of the AGV. In this paper, we propose ceiling Light and guided line based moving direction estimation algorithm using multi-camera on the AGV in smart factory that can operate stable AGV by compensating the disadvantages of existing AGV operation method. The proposed algorithm is able to estimate its position and direction using a general - purpose camera instead of a sensor. Based on this, it can correct its movement error and estimate its own movement path.

A Study on Real time Multiple Fault Diagnosis Control Methods (실시간 다중고장진단 제어기법에 관한 연구)

  • 배용환;배태용;이석희
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.04b
    • /
    • pp.457-462
    • /
    • 1995
  • This paper describes diagnosis strategy of the Flexible Multiple Fault Diagnosis Module for forecasting faults in system and deciding current machine state form sensor information. Most studydeal with diagnosis control stategy about single fault in a system, this studies deal with multiple fault diagnosis. This strategy is consist of diagnosis control module such as backward tracking expert system shell, various neural network, numerical model to predict machine state and communication module for information exchange and cooperate between each model. This models are used to describe structure, function and behavior of subsystem, complex component and total system. Hierarchical structure is very efficient to represent structural, functional and behavioral knowledge. FT(Fault Tree). ST(Symptom Tree), FCD(Fault Consequence Diagrapy), SGM(State Graph Model) and FFM(Functional Flow Model) are used to represent hierachical structure. In this study, IA(Intelligent Agent) concept is introduced to match FT component and event symbol in diagnosed system and to transfer message between each event process. Proposed diagnosis control module is made of IPC(Inter Process Communication) method under UNIX operating system.

  • PDF