• Title/Summary/Keyword: Flat type sample

Search Result 26, Processing Time 0.022 seconds

Material Noise Reduction in Ultrasonic Test Using Polarity Thresholding Algorithm (초음파탐상 수행시 Polarity Thresholding 알고리즘을 이용한 재료잡음 억제)

  • Koo, Kil-Mo;Ko, Dae-Sik;Kim, Tae-Hyoun;Jun, Kye-Suk
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.1
    • /
    • pp.73-80
    • /
    • 1995
  • In this paper, Polarity Thresholding(PT) algorithm has been studied to enhance the received signal in ultrasonic inspection of the stainless-steel(SUS 304) which is the primary piping material of a nuclear power plant. The spectral decomposition components obtained by splitting the spectrum of received signals are composed of dispersive signal of the interference pattern produced by the grain boundaries and nondispersive signal by the flaw. PT algorithm enhance the SNR of received signal by using above properties. In experiment the stainless-steel has been chosen as the sample and heat-treated at 1125, 1150, 1175, and $1200^\circ{C}$, respectively. And the flat-bottom hole type defects have been made artificially in samples. The pulse-echo signals from the sample by using ultrasonic transducer of center frequency 5 MHz have been processed by PT algorithm. It has been shown that PT algorithm enhanced the SNR by average 14.2 dB.

  • PDF

Submicron-scale Polymeric Patterns for Tribological Application in MEMS/NEMS

  • Singh R. Arvind;Yoon Eui-Sung;Kim Hong Joon;Kong Hosung;Jeong Hoon Eui;Suh Kahp Y.
    • KSTLE International Journal
    • /
    • v.6 no.2
    • /
    • pp.33-38
    • /
    • 2005
  • Submicron-scale patterns made of polymethyl methacrylate (PMMA) were fabricated on silicon-wafer using a capillarity-directed soft lithographic technique. Polyurethane acrylate (PUA) stamps (Master molds) were used to fabricate the patterns. Patterns with three different aspect ratios were fabricated by varying the holding time. The patterns fabricated were the negative replica of the master mold. The patterns so obtained were investigated for their adhesion and friction properties at nano-scale using AFM. Friction tests were conducted in the range of 0-80 nN. Glass (Borosilicate) balls of diameter 1.25 mm mounted on cantilever (Contact Mode type NPS) were used as tips. Further, micro-friction tests were performed using a ball-on-flat type micro-tribe tester, under reciprocating motion, using a soda lime ball (1 mm diameter) under a normal load of 3,000 mN. All experiments were conducted at ambient temperature ($24{\pm}1^{\circ}C$) and relative humidity ($45{\pm}5\%$). Results showed that the patterned samples exhibited superior tribological properties when compared to the silicon wafer and non-patterned sample (PMMA thin film) both at the nano and micro-scales, owing to their increased hydrophobicity and reduced real area of contact. In the case of patterns it was observed that their morphology (shape factor and size factor) was decisive in defining the real area of contact.

A Case of Stickler Syndrome Type I Caused by a Novel Variant of COL2A1 Gene (COL2A1 유전자의 새로운 돌연변이에 의한 제 1형 Stickler 증후군으로 진단된 1례)

  • Lee, Jin;Jung, Chang-Woo;Kim, Gu-Hwan;Lee, Beom-Hee;Choi, Jin-Ho;Yoo, Han-Wook
    • Journal of Genetic Medicine
    • /
    • v.8 no.2
    • /
    • pp.125-129
    • /
    • 2011
  • Stickler syndrome is a very rare connective tissue disorder. The authors of the present study describe an 11-month-old girl with high myopia, retinal abnormalities, flat nose, cleft palate, retrognathia, micrognathia, short stature and arthrogryposis. Radiological evaluation also showed irregularity of the epiphysis of the femur and tibia and spondyloepiphyseal dysplasia. Genetic analysis using a peripheral blood sample revealed a novel variant c.787G>A (p.Gly246Asp) mutation of the COL2A1 gene. This is the first Korean case with Stickler syndrome confirmed by genetic testing.

Influences of Shoe Shape and Gait Characteristics on Feet Discomforts according to Women′s Foot Type (발의 불편감에 영향을 미치는 구두형태 및 보행특성 -성인 여성을 중심으로-)

  • 최순복;이원자
    • The Research Journal of the Costume Culture
    • /
    • v.10 no.3
    • /
    • pp.306-317
    • /
    • 2002
  • The Sample was consist of 216 female adults who were selected with my convenience from residing women in and around Seoul, Korea. The result were as fellowing; According to the factor analysis of their foot discomfort, it is divided into 3 factors: the discomfort of whole body (factor 1), the discomfort of foot sole (factor 2), and the discomfort of toes (factor 3). And the foot part of discomfort is more frequent in the order of the big toe, 2·3 metatarsal bones, and the little toe. As the age gets older, the discomfort of foot sole and toes are reported more frequently, and, particularly, more student and office employees have the discomfort of whole body while more sales women and housewives have the discomfort of foot sole. In terms of the shoe types, the higher the hill height, the more the discomfort of foot sole with wearing the sharp toe. As the wearing time is longer, the discomfort of foot sole increases. Being related to the from patterns, the broad and short type has more of the discomfort of foot sole, the flat foot feel more discomfort from the entire body and the sole. Walking with leaning toward the frontal the discomfort on toes and sole increases.

  • PDF

Experimental Study for Phase-contrast X-ray Imaging Based on a Single Antiscatter Grid and a Polychromatic X-ray Source (단일 비산란 그리드 및 다색광 x-선원 기반 위상대조 x-선 영상화 실험 연구)

  • Park, Yeonok;Cho, Hyosung;Lim, Hyunwoo;Je, Uikyu;Park, Chulkyu;Cho, Heemoon;Kim, Kyuseok;Kim, Guna;Park, Soyoung
    • Progress in Medical Physics
    • /
    • v.26 no.4
    • /
    • pp.215-222
    • /
    • 2015
  • In this work, we performed a proof-of-concept experiment for phase-contrast x-ray imaging (PCXI) based on a single antiscatter grid and a polychromatic x-ray source. We established a table-top setup which consists of a focused-linear grid having a strip density of 200 lines/inch, a microfocus x-ray tube having a focal-spot size of about $5{\mu}m$, and a CMOS-type flat-panel detector having a pixel size of $48{\mu}m$. By using our prototype PCXI system and the Fourier demodulation technique, we successfully obtained attenuation, scattering, and differential phase-contrast images of improved visibility from the raw images of several selected samples at x-ray tube conditions of $90kV_p$ and 0.1 mAs. Further, fusion image (e.g., the attenuation+the scattering) may have an advantage in displaying details of the sample's structures that are not clearly visible in the conventional attenuation image. Our experimental results indicate that single-grid-based approach seems a useful method for PCXI with great simplicity and minimal requirements on the setup alignment.

CUTTING EFFICACY OF Er:YAG LASER AND CONVENTIONAL BUR IN DECIDUOUS AND PERMANENT TEETH (Er:YAG laser와 Conventional bur의 유치와 영구치 치아삭제효과 비교)

  • Park, In-Cheon;Lee, Chang-Seop;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.2
    • /
    • pp.272-285
    • /
    • 2003
  • This study was conducted to observe the microscopic structures of cavities formed after ablation of primary teeth, permanent teeth, enamel and dentin in using a bur and cavities formed after ablation using laser and the following results were obtained after comparing the effects of ablation. Using a #330 bur and Er:YAG laser irradiated at 150 mJ, 200 mJ, 250 mJ and 300 mJ all at the frequency of 5 Hz, 1 mm enamel and dentin samples were ablated and the ablation time was measured. In order to measure the surfaces ablated, 5 each of primary teeth and permanent teeth were ablated using a #330 bur and Er:YAG laser at 150 mJ, 200 mJ, 250 mJ and 300 mJ for 1 sec and the cross section and vertical section were observed. The following results were obtained : 1. Cutting time of Er:YAG laser was longer than that of conventinal high-speed bur regardless of teeth type. 2. Cutting on enamel, Cutting time of conventional high-speed bur in deciduous teeth was longer than in permanent teeth(P<0.05). But Er:YAG laser was not showed any difference between the deciduous and permanent teeth(P>0.05). 3. Cutting on dentin, Cutting time of conventional high-speed bur in permanent teeth was longer than deciduous teeth. Er:YAG laser of 150 mJ, 5 Hz in permanent teeth was longer than in deciduous teeth(p<0.05). But laser of other power did not showed mean difference. 4. The cavity surface treated with the convetional high-speed bur revealed a relatively flat appearance, almost covered with a debris-like smear layer. Cavity wall showed striped appearance because of blade of bur. 5. The cavity surface treated by the Er:YAG laser system was irregular or rough surface with the absence charring, carbonization, or cracking of the dentin. In addition, there was an absence of a smear layer. Cavity floor was round and relatively smooth. According to these results, cutting time of Er:YAG laser was almostly same in permanent and deciduous teeth, but more effective in dentin than enamel. Cutting the sample, Er:YAG laser was needed more time than conventional bur. But SEM findings suggested that laser device produced favorable surface characteristic(i.e, no smear layer, irregular surface, cracking).

  • PDF