• Title/Summary/Keyword: Flat type sample

Search Result 26, Processing Time 0.207 seconds

Merging Features and Optical-NIR Color Gradient of Early-type Galaxies

  • Kim, Du-Ho;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.36 no.1
    • /
    • pp.57.1-57.1
    • /
    • 2011
  • It has been suggested that merging plays an important role in the formation and the evolution of early-type galaxies (ETGs). Optical-NIR color gradients of ETGs in high density environments are found to be less steep than those of ETGs in low density environments, hinting frequent merger activities in ETGs in high density environments. In order to examine if the flat color gradients are the result of dry mergers, we studied the relations between merging features, color gradient, and environments of 281 low redshift ETGs selected from Sloan Digital Sky Survey (SDSS) Stripe82. The sample contains 222 relaxed ETGs, 38 ETGs with tidal features, 10 galaxies with dust features and 11 galaxies with tidal and dust features, and Near Infrared (NIR) images are taken from UKIRT Infrared Deep Sky Survey (UKIDSS) Large Area Survey (LAS). We find that r-K color gradients of field sample galaxies are steeper than those of sample ETGs within cluster environments. For the field sample galaxies, a relatively large number of galaxies with peculiar features contribute to the steeper color gradients, while the absence of these peculiar early-type galaxies make color gradients of the cluster sample galaxies intact. In high density environment, ETGs are already evolved and relaxed, resulting flat color gradients. However, in low density environments, a majority of ETGs undergone merging recently which makes the color gradients steep.

  • PDF

A Comparative Study on the Retention of Implant Overdenture According to the Shape and the Number of Magnetic Attachment (자성 어태치먼트의 형태와 수에 따른 하악 임플란트 피개의치의 유지력에 대한 비교 연구)

  • Seo, Min-Ji;Lee, Joon-Seok;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.24 no.2
    • /
    • pp.169-181
    • /
    • 2008
  • The aim of this study was to compare the retention and stability of implant overdenture according to the shape and the number of magnetic attachment. The experimental groups were designed for the number of implants(1, 2, 4) and shape of magnetic attachments(flat, cushion, dome type) resulting in 9 subgroups. 45 attachments were tested attached to $Br{\aa}nemark$ system implants which were planted on a mandibular model. Each attachment was composed of the magnet assembly embedded in a overdenture sample and the abutment keeper screwed into the implants. Dislodging tensile forces were applied to the overdenture samples using an Instron(cross-head speed 50.80mm/min) in 3 directions simulating function: vertical, oblique, and anterior-posterior. The loading was repeated 10 times in each direction for 45 samples. The values of maximum dislodging force of each subgroup were processed statistically using SPSS V. 12.0 at the 0.05 level of significance. The results of this study were as follows: 1. Flat type magnetic overdenture was the most retentive when subjected to vertically directed forces and dome type was the lest retentive when subjected to obliquely directed forces(p<0.05). 2. In case of planting one implant, flat type had a higher vertically retentive force than anterior-posteriorly retentive force. In case of planting two implants, flat type and dome type had a higher vertically retentive force and in case of planting four implants, flat type and cushion type had a higher vertically retentive force than anterior-posteriorly retentive force(p<0.05). 3. The incremental number of dental implant, without regards to the three types of magnetic attachment shapes, showed higher retention of overdenture(p<0.05). From the results, if a patient need much more retention of implant overdenture, flat type magnetic overdenture would be a good treatment. In case of the bruxism where excessive lateral forces are already present, dome type could be expected to produce better results. In case of planting one implant, flat type is more stable than the other shape of magnet and in case of two implant, flat type and dome type are more stable and in case of four implants, flat type and cushion type are more stable. Planting more than two implants and using flat type magnetic attachment would provide better retention and stability of implant overdenture

Transmission Electron Microscopy Specimen Preparation of Delicate Materials Using Tripod Polisher

  • Cha, Hyun-Woo;Kang, Min-Chul;Shin, Keesam;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • v.46 no.2
    • /
    • pp.110-115
    • /
    • 2016
  • Transmission electron microscopy (TEM) is a powerful tool for analyzing a broad range of materials and provides localized information about the microstructure. However, the analysis results are strongly influenced by the quality of the thin foil specimen. Sample preparation for TEM analysis requires considerable skill, especially when the area of interest is small or the material of interest is difficult to thin because of its high hardness and its mechanical instability when thinned. This article selectively reviews recent advances in TEM sample preparation techniques using a tripod polisher. In particular, it introduces two typical types (fl at type and wedge type) of TEM sample preparation and the benefits and drawbacks of each method; finally, a method of making better samples for TEM analysis is suggested.

A Study on Characteristics and Correspondence of Men's Back and Chest Types (20대 남성의 등면 및 가슴부위 형태특성과 대응에 관한 연구)

  • Paek, Kyung-Ja;Lee, Jeong-Ran
    • Fashion & Textile Research Journal
    • /
    • v.6 no.3
    • /
    • pp.357-366
    • /
    • 2004
  • The purpose of this study is to classify the types of men's back and chest through the criteria which represent the characteristic of men's back and chest. We have the following conclusions based on our sample size of 291 men's back and chest. The result of factor analysis concerned with men's back indicates that six factors are extracted and they are consist of 80.6% of total variance. We divide the shape of back into three categories: bent, protrusion of the scapula, and breadth. Each category is divided into subcategories. According to the frequency based on our data entries of 291 men's back, we introduce five new types of men's back. 83.8% of examined men's back belong to one of these five types: (i) 15.5% of protrudent and lordotic type; (ii) 6.5% of flat and lordotic type; (iii) 22.7% of protrudent and normal type; (iv) 34.4% of flat and normal type; (v) 4.8% of flat and bent type. The result of factor analysis related to with men's chest shows that six factors are extracted and they are consist of 76.0% of total variance. We divide the shape of chest into three categories: thickness, breadth, and protrusion of the breast. Each category is divided into subcategories. According to the frequency based on our data entries of 291 men's chest, we introduce four new types of men's chest. 65.0% of examined men's chest belong to one of these four types: (i) 7.2% of full and well-developed type; (ii) 24.1% of full and developed type; (iii) 25.8% of flat and developed type; (iv) 7.9% of flat and under-developed type. In order to consider the shape of the upper body as a whole, the back and the chest types should be corresponded.

PCR Approach for Detection and Typing of Epidermodysplasia Verruciformis-associated Human Papillomavirus Types

  • Shin, Yong-Jae;Choi, Hyun-Chul;Kim, Chan-Gil;Lee, Kwang-Ho
    • The Journal of Korean Society of Virology
    • /
    • v.29 no.1
    • /
    • pp.39-44
    • /
    • 1999
  • Warts, or verrucae, are benign epithelial proliferations of the skin and mucosa caused by infection with human papillomaviruses (HPV). It is now recognized that there are many different HPV types. Especially type3 is most frequently observed in flat wart. Other types, such as type2, 10, 14, 27, 28, 29, 38, and 41 are rarely encounted in flat wart. We describe here a simple and economic method for detection and identification of epidermodysplasia verruciformis-associated HPV. The method is based on polymerase chain reaction (PCR) amplification and restriction analysis. The method has been developed with cloned HPV DNA and DNA from clinical samples. Clinical samples are from either frozen tissue or paraffin-embedded tissue. Genomic fragments were obtained from two different HPV types (3 and 10). The amplification fragments were identified by a form of miniature fingerprinting, with a set of restriction enzymes that gave a unique digestion pattern for each HPV type. We have tested 74 clinical samples. Only type3 among these clinical samples is detected, and one sample is involved in neither type3 nor type10.

  • PDF

Merging Features and Optical-NIR Color Gradient of Early-type Galaxies

  • Kim, Du-Ho;Im, Myeong-Sin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.2
    • /
    • pp.41.1-41.1
    • /
    • 2010
  • It has been suggested that merging plays an important role in the formation and the evolution of early-type galaxies. Optical-NIR color gradients of early-type galaxies in high density environments are found to be less steep than those in low density environment, hinting frequent merger activities in early-type galaxies in high density environment. In order to confirm if the flat color gradient is the result of dry merger, we decided to look deeply to find merging features and get their relation with color gradient. We selected samples which show extreme values of optical-NIR color gradients based on the data of previous study, and observed them at Maidanak observatory 1.5m telescope with long exposure. After masking out overlaid sources, our analysis reveals that these galaxies do not have extreme color gradient values. High degree sky flat technique was used during observation to aid discovery of faint, extended features. However, flatness of detector (SNUCAM) was good enough, so we could not see any marked improvement in image quality compared to those using normal sky flats. Additionally we noticed a feature that looks like merging tidal tail in the CFHT archival image, but this does not show up on the image we obtained. This demonstrates that flatness and correct sky estimation is very important when we look for faint merging features. In future we plan to enlarge the number of the sample.

  • PDF

A Comparison of the Foot Dimensions and Foot Characteristics of Adult Obese Men using Body Mass Index (체질량지수에 따른 발 치수 비교 및 비만 성인 남성의 발 특성 연구)

  • Namsoon Kim;Wolhee Do
    • Fashion & Textile Research Journal
    • /
    • v.25 no.1
    • /
    • pp.52-61
    • /
    • 2023
  • This study aimed to present data for the development of a shoe which is suitable for plus-size men (BMI 25kg/m2 or higher) and to analyze the characteristics of each type of foot. The results of the study are as follows. To assess foot shape in relation to weight gain, participants were categorized into normal weight, overweight, and obese weight groups, according to their BMI indexes. Those in the normal weight group exhibited a smaller value than the overweight or obese weight group in all items. As a result of the cluster analysis, by type of foot, of the obese men category, men were classified into four BMI index groups: members of the type 1 group had a BMI index of 157 (18.4% of total sample), while for type 2 the figure was 213 (25.0% of sample), for type 3 it was 259 (30.4%), and for type 4 it stood at 224 (26.3% of total sample). Those from the type 1 group had thin ankles with narrow toes and flattened sides. Type 2 group members had thick ankles with well-developed outer feet and thick sides. Those within the type 3 group had medium-thick ankles with narrow feet but wide inner feet. Finally, those in the type 4 group had feet with a slanted side, as well as thick ankles, wide feet, and flat sides. Among these categories, the type 3 group members indicated the highest distribution.

The influence of the number and the type of magnetic attachment on the retention of mandibular mini implant overdenture

  • Lee, Eunjee;Shin, Soo-Yeon
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.1
    • /
    • pp.14-21
    • /
    • 2017
  • PURPOSE. The aim of this study was to compare the retention of mini implant overdenture by the number, the type of magnetic attachment, and the directions of applied dislodging force. MATERIALS AND METHODS. The experimental groups were designed by the number and type of magnetic attachment. Twenty samples were tested with Magden implants. Each attachment was composed of the magnet assembly in overdenture sample and the abutment keeper in a mandibular model. Dislodging forces were applied to the overdenture samples (50.0 mm/min) in 3 directions. The loading was repeated 10 times in each direction. The values of dislodging force were analyzed statistically using SPSS at 95% level of confidence. RESULTS. The retentive force of group 2 was greater than that of group 1 in both types of attachment in every direction (P < .05). Oblique retentive force of flat type magnetic attachment was higher than that of cushion type attachment in both groups (P < .05). In group 1, oblique retentive force showed the highest and anterior-posterior retentive force showed the lowest value in both attachment types (P < .05). In group 2, both types of attachment showed the lowest retentive force with anterior-posterior direction of dislodging force (P <.05). CONCLUSION. Proper retentive properties for implant overdenture were obtained, regardless of the number and type of magnetic attachment. In both types of magnetic attachment, the greater retentive force was attained with more implants. Oblique retentive force of flat type magnetic attachment was greater than that of cushion type. Among all subgroups, anterior-posterior retentive force was the lowest among three different directions of dislodging force.

Thalassobius aestuarii sp. nov., Isolated from Tidal Flat Sediment

  • Yi Ha-Na;Chun Jong-Sik
    • Journal of Microbiology
    • /
    • v.44 no.2
    • /
    • pp.171-176
    • /
    • 2006
  • A strictly aerobic, non-motile, ovoid-shaped Alphaproteobacteria, designated strain $JC2049^T$ was isolated from a tidal flat sediment sample. The results of 16S rRNA gene sequence analysis indicated that this isolate belonged to the genus Thalassobius, with a sequence similarity of 96.9-97.3% to other valid Thalassobius spp. The cells required 1-7% NaCl for growth (optimum 2%) and accumulated $poly-\beta-hydroxybutyrate$. Nitrite was reduced to nitrogen, but nitrate was not reduced to nitrite. No genetic potential for aerobic anoxygenic photosynthesis was detected. The primary isoprenoid quinone (Ubiquinone-10), predominant cellular fatty acids $(C_{18:1}{\omega}7c,\;11\;methyl\;C_{18:1}\omega7c\;and\;C_{16:0})$ and DNA G+C content (61 mol %) were all consistent with the assignment of this isolate to the genus Thalassobius. Several phenotypic characteristics clearly distinguished our isolate from other Thalassobius species. The degree of genomic relatedness between strain $JC2049^T$ and other Thalassobius species was in a range of 20-43 %. The polyphasic data presented in this study indicates that our isolate should be classified as a novel species within the genus Thalassobius. The name Thalassobius aestuarii sp. novo is therefore proposed for this isolate; the type strain is $JC2049^T(=IMSNU\;14011^T=KCTC\;12049^T=DSM\;15283^T)$.

Development of the Ion Source of Glow Discharge/Mass Spectrometry for the determination of trace elements (미량원소 분석을 위한 GD/MS 이온원의 개발에 관한 연구)

  • Woo, Jin Chun;Lim, Heoung Bin;Moon, Dae Won;Lee, Kwang Woo;Kim, Hyo Jin
    • Analytical Science and Technology
    • /
    • v.5 no.2
    • /
    • pp.169-176
    • /
    • 1992
  • Analytical detection limits and Relative Ion Yield (RIY) by a jet type ion source glow discharge mass spectrometer(GD/MS) have been measured. With a jet type ion source, the sample loss rate for a Cu sample is 0.23 mg/min with 0.1 L/min gas flow rate and 0.11 mg/min with no gas flow rate. However, the ion intensity of Cu does not change significantly with thee variation of the gas flow rate. The RIY values obtained from the calibration curves of the six copper based standards were between 0.57 of Fe and 3.5 of Cr. The detection limits of most elements were in the range of 0.9 and 2.0 ppm when the glow discharge was operated at 4 mA, 1000V.

  • PDF