• 제목/요약/키워드: Flame length

검색결과 327건 처리시간 0.025초

Plasma Jet의 동축평행자계에 의한 영향에 관한 연구 2 (A Study on the Influence Coaxial Parallel Magnetic Field upon Plasma Jet (II))

  • 전춘생
    • 전기의세계
    • /
    • 제22권5호
    • /
    • pp.19-32
    • /
    • 1973
  • This paper treats with some of plasma jet behaviors under magnetic field for the purpose of controlling important characteristics of plasma jet in the practices of material manufacturings. Under the existence and non-existence of magnetic field, the pressure distribution, flame length, stability and noise of plasma jet are comparatively evaluated in respect of such parameters as are current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle. The results are as follows: 1) the pressure, the length and the noise of plasma jet rise gradually with the increase of are current, and have high values under identical arc current as the diameter of nozzle increases, but reverse phenomenon tends to appear in the noise. 2) The pressure, the flame length and the noise increase with the increased quantity of argon flow, and the rising slope of noise is particularly steep. Under magnetic field, the quantity of argon flow in respect of flame length has the critical value of 80(cfh). 3) The pressure and length of flame decrease with small gradient value as the length of gap increases, but the noise tends to grow according to the increase of nozzle diameter. 4) The pressure and the length of jet flame decrease inversly with the increase of magnetic flux density, which have one critical value in the 100 amps of arc current and two values in 50 amps. The pressure of jet flame can be below atomospher pressure in strong magnetic field. 5) "The constriction length of nozzle has respectively the critical value of 6(mm) for pressure and 23(mm) for the length of flame. 6) Fluctuations in the wave form of voltage become greater with the increase of argon flow and magnetic flux density, but tends to decrease as arc current increases, having the frequency range of 3-8KHz. The wave form of noise changes almost in parallel with that of voltage and its changing value increases with argon flow, arc current and magnetic flux density, having the freuqency range of 6-8KHz. The fluctuation of jet presurre is reduced with the increase of argon flow and magnetic flux density and grows with arc current.rent.

  • PDF

모형 가스터빈 연소기에서의 스월수와 혼합길이에 따른 화염구조와 NOx배출에 관한 실험적 연구 (The Study on Flame Structure and NOx Emissions by Swirl Numbers and Fuel-Air Mixing Length in a Dump Combustor Gas Turbine)

  • 최도욱;김규보;전충환;송주헌;장영준
    • 대한기계학회논문집B
    • /
    • 제33권11호
    • /
    • pp.849-857
    • /
    • 2009
  • The experimental study was performed to investigate the effects of partial premixing, varying the equivalence ratio, mixing degree, swirl intensity, mixing length on the characteristics of flame structure and NOx emission. Experiments were conducted in a dump combustor at 1 bar using methane as fuel. Inlet air temperature was 570K. OH chemiluminescence images were acquired with an ICCD camera. As a result of the experimental investigation of characteristics of flame and NOx emission in partial premixed combustor, we can conclude the results as below. With the increase of swirl number, The flame length decreases and the flame width increases and it helps flame stabilization. It means that lean flammability limit is extended. With the increase of mixing of fuel-air length ratio, Flame goes to be stabilized and NOx emission and $OH^{\ast}$ intensity decrease. Through the comparison of preceding results, It is possible that the exhausted NOx emission from a gas turbine combustor will be able to predict through the $OH^{\ast}$ intensity.

합판(合板)의 내화처리(耐火處理)에 관(關)한 연구(硏究) - III. 제1인산(第一燐酸)암모늄처리합판(處理合板)의 내화도(耐火度) (Studies on Plywood Treated Fire-Retardant - III. The Fire-Retardant Degree of Monoammonium Phosphate Treated Plywood)

  • 김종만
    • Journal of the Korean Wood Science and Technology
    • /
    • 제14권4호
    • /
    • pp.21-28
    • /
    • 1986
  • Plywood used for construction as a decorative inner material is inflammable and can fire accident, causing destruction of human life and property. In this study, 3.5mm Kapur plywoods were soaked in the 23% monoammonium phosphate solutions by cold soaking method 3, 6, 9hrs and hot-cold bath method for 3/3hrs, and redrying was carried out by press-drying at the platen temperature of 110, 130, 160, 180$^{\circ}C$, and then fire test was carried out to investigate burning point, flame exhausted length, frame spread length, back side carbonized area and weight loss. The results are as follows; 1. In cold soaking method for 3, 6, 9hrs. retentions of monoammonium phosphate were 0.377, 0.448, 0.498kg/(30cm)$^3$ respectively, and in hot-cold bath method for 3/3hrs, the retention was 1.331kg(30cm)$^3$ that exceeded the minimum retention 1.124kg/(30cm)$^3$. 2. Correlation coefficients among the variable were shown in table 2. From the table, it could be recognized that there were close negative correlations between the treatment and burning point, flame spread length, back side carbonized area, flame exhausted time and weight loss, and there was negative correlation between treating time and back side carbonized area, but there was positive correlation between platen temperature and burning point. 3. From table 3, it can be observed that there were highly significant differences for burning point, flame spread length, flame exhausted time, back side carhonized area, weight loss between treatments. And in 2-way interactions, there were also highly significant for burning point, flame spread length, flame exhausted time, weight loss between time x treatment. 4. It was observed that burning point, flame exhausted time, flame spread length, back side carbonized area, and weight loss in fire-retardant treated plywood were the best effects in fire-retardant treated plywood, water treated plywood and nontreated plywood. In conclusion, I can estimate that absorbed chemical contents by hot-cold bath method for 3/3hrs, have a lot of effects on fire-retardant factors such as burning point, flame spread length, flame exhausted time, backside carbonized area and weight loss, but platen temperatures have a little effects on the fire factors.

  • PDF

희석된 동축공기 수소 난류확산화염의 화염 길이 스케일링 (Flame Length Scaling in a Non-premixed Turbulent Diluted Hydrogen Jet with Coaxial Air)

  • 황정재;오정석;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2009년도 제33회 추계학술대회논문집
    • /
    • pp.242-245
    • /
    • 2009
  • 희석된 동축공기 수소 난류확산화염에서 연료의 구성이 화염 길이에 미치는 영향에 대한 연구를 수행하였다. 화염의 길이는 동축공기와 연료 제트의 속도비의 함수로 표현하였고, 이론적 예측과 비교하였다. 네 조건의 연료 구성에 대해 연구를 수행하였다. 동축공기 제트 화염의 길이 예측을 위해 near-field concept에서의 유효 직경을 이용한 스케일링 관계식을 유도하였다. 실험 결과 가시 화염의 길이는 이론적 예측과 크게 일치하였다. 여러 연료 조건에서의 희석된 수소 제트의 화염에서도 스케일링 분석은 유효하였다.

  • PDF

난연 처리가 종이의 난연성 및 인장강도에 미치는 영향 (Effect of Treatments with Flame-retardant on Flame-resistance and Tensile Strength of Paper)

  • 송한규;이명구
    • 펄프종이기술
    • /
    • 제38권4호
    • /
    • pp.61-67
    • /
    • 2006
  • The effect of several inorganic flame-retardants such as ammonium phosphate, ammonium sulfate, aluminum hydroxide and antimony trioxide on the flame-retardant property and tensile strength of paper has been investigated. Flame-retardants were used preferably as a dry powdered mixture and added to the furnish. Both dipping and coating treatments were employed to apply flame-retardants to paper Flame-retardant paper was manufactured by treatment of $5{\sim}30%$ flame-retardants by weight of the paper on a dry weight. Paper's flame-retardant property and tensile strength were examined by comparison of char length and tensile index. As dosages of flame-retardant chemicals increased, flame-retardant property was improved but tensile index was decreased.

비예혼합 화염에서 음향 가진이 연소 배출 특성에 미치는 영향 (Effects of acoustic excitation on the combustion emission characteristics of a non-premixed flame)

  • 이기만;박정;조한창
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.878-883
    • /
    • 2001
  • The effects of external excitation with various frequencies and amplitudes on the flame behavior and pollution emission characteristics from a laminar jet flame are experimentally investigated. Measurements of $NO_{x}$ emission indices($EINO_{x}$), performed in unconformed and vertical lifted flame at resonance frequency by strong excitation, have been conducted experimentally. It was also conducted to investigate the effects of excited frequency on $NO_{x}$ emissions with a various frequency ranged 0Hz to 2kHz. From the vertical lifted flame like turbulent of the excited jet with resonance frequency was shown that the dependence of $NO_{x}$ emission could be categorized into three groups: Group 1 of intermediate flame length and relative narrow flame volume yielding low $NO_{x}$ emission, Group 2 of short flame length but large flame volume yielding high $NO_{x}$ emission and Group 3 of long flame length with low temperature contours yielding high $NO_{x}$ emission.

  • PDF

등유-산소 층류 확산화염의 길이 변화 특성에 관한 실험적 연구 (Experimental Investigations of the Characteristics of the Length Variation of Kerosene-Oxygen Laminar Diffusion Flames)

  • 이수한;이종원;박설현
    • 한국화재소방학회논문지
    • /
    • 제32권6호
    • /
    • pp.22-27
    • /
    • 2018
  • 등유-산소 동축류 확산화염 버너에서 연료의 유량, 버너 외축에 공급되는 산화제의 온도, 불활성가스로 희석된 산화제의 특성이 화염 길이 변화 특성에 미치는 영향을 고찰해 보았다. 각 실험 조건에서 생성된 동축류 확산 화염은 쉴리렌 카메라를 이용하여 촬영한 뒤 디지털 이미징 프로세싱 기법을 적용하여 그 길이를 측정하였다. 실험결과를 통해 측정된 화염길이는 등유 연료의 유량과 산화제의 온도에 비례하여 증가하는 것을 확인할 수 있었다. 아울러, 산화제에 첨가되는 불활성가스의 희석량이 증가할수록 화염 길이는 증가하는 하였고, 특히 동일한 산소 농도에서 질소가스로 희석된 경우가 헬륨가스로 희석된 경우에 비해 화염길이가 큰 폭으로 증가하였다. 이는 유체의 점성 저항에 영향을 미치는 불활성가스의 희석이 화염 길이 변화에 영향을 미치는 주요 메카니즘이기 때문으로 판단된다.

선도체 대 평면전극 갭에서 평면전극에 연소화염 존재시 대기의 절연파괴 특성 (Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제27권4호
    • /
    • pp.73-80
    • /
    • 2013
  • Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.

평단봉대평판 전극배치에서 평판 전극에 화염이 존재할 때 공기의 섬락전압 특성 (Flashover Characteristics of Air in the Arrangement of Cylinder-Shaped Rod and Plane Electrode in Case of Flame on the Plane Electrode)

  • 김인식
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.82-87
    • /
    • 2012
  • In this paper, flashover characteristics of air in the vertical arrangement of cylinder-shaped rod and plane gap in the case of combustion flame on the plane electrode were examined under the application of a.c. and d.c. high-voltages. In order to investigate the effect of propane flame on the flashover characteristics of air, flashover voltages in accordance with the variation of the gap length and the horizontal distance between the flame and the high-voltage rod electrode were measured. As the result of the experiment, flashover voltages in the presence of the flame were substantially lowered than those in the absence of flame, and the polarity effects with the d.c. voltages on appeared owing to the flame. Flashover voltages of air were increased in the proportion of the gap length and the horizontal distance in the case of both a.c. and d.c. voltages, but the flame was extinguished by such corona wind that was produced from the rod electrode when the gap length and the horizontal distance reached to a certain degree.

이산화탄소로 희석된 메탄-공기 확산화염의 에지화염 불안정성 (Edge Flame Instability of CH4-Air Diffusion Flame Diluted with CO2)

  • 황동진;김정수;길상인;김태권;박정
    • 대한기계학회논문집B
    • /
    • 제30권9호
    • /
    • pp.905-912
    • /
    • 2006
  • Experiments in low strain rate methane-air counterflow diffusion flames diluted with $CO_2$ have been conducted to investigate the flame extinction behavior and edge flame oscillation in which flame length is less than the burner diameter and thus lateral conductive heat loss in addition to radiative loss could be remarkable at low global strain rates. The critical mole fraction at flame extinction is examined in terms of velocity ratio and global strain rate. It is seen that flame length is closely relevant to lateral heat loss, and this sheets flame extinction and edge flame oscillation considerably. Lateral heat loss causes flame oscillation even at fuel Lewis number less than unity. Edge flame oscillations are categorized into three: a growing-, a harmonic- and a decaying-oscillation mode. Onset conditions of the edge flame oscillation and the relevant modes are examined with global strain rate and $CO_2$ mole fraction in fuel stream. A flame stability map based on the flame oscillation modes is also provided at low strain rate flames.