Breakdown Characteristics of Air in the Gap between Line Conductor and Plane Electrode in Case of Combustion Flame on the Plane Electrode  

Kim, In-Sik (Kyungil University, School of Railway and Electrical Engineering)
Publication Information
Journal of the Korean Institute of Illuminating and Electrical Installation Engineers / v.27, no.4, 2013 , pp. 73-80 More about this Journal
Abstract
Breakdown characteristics of air in the vertical arrangement of line conductor and plane electrode in case of combustion flame on the plane electrode are examined by the application of AC. and DC voltages to the gap. In order to investigate the effect of paraffin flame on the breakdown characteristics of air, flashover voltages are measured according to the variation of the gap length and the horizontal distance between the flame and the line conductor. As the result of the experiment, flashover voltages are substantially lowered down to 29.8% in case of the AC voltage, and 16.1% in case of the negative DC voltage, when in the presence of the flame. from 100% when in the absence of flame. Flashover voltages of air in the range of smaller than 3㎝ at the horizontal distance are increased in the proportion of the gap length and the horizontal distance in case of both AC and negative DC voltages. But before the flashover occurs, the flame is extinguished by such corona wind that is produced from the line conductor when the gap length and the horizontal distance reach to a certain degree. The effect of relative air density and the phenomenon of thermal ionization are analysed as the reduction factors of flashover voltages, due to high temperature of the flame.
Keywords
Breakdown Voltage; Flashover Voltage; Electrode System; Combustion Flame;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 E. Kuffel, W. S. Zaengle, "High Voltage Engineering, Fundamentals", Pergamon Press, pp.297-377, 1984.
2 I. Kim, "Flashover Characteristics of Air in the Arrangement of Cylinder-Shaped Rod and Plane Electrode in Case of Flame on the Plane Electrode", Journal of KIIEE, Vol. 26, No. 4, pp. 82-87, 2012.   과학기술학회마을   DOI   ScienceOn
3 http://www. forest. go. kr. "Korea Forest Service Website"/Forest Fire Information January 2013.
4 J. D. Boom, "The Effect of DC Electric Field on Laminar Burning Velocity of Air Flames", Proceeding of the Combustion Institute, vol. 32, No. 1, pp. 1237-1244, 2009.   DOI   ScienceOn
5 I. Kim, "Breakdown Characteristics of a Vertical Sphere-Plane Air-Gap in the Presence of Combustion Flame", Journal of KIIEE, Vol. 25, No. 5, pp. 79-84, 2011.   과학기술학회마을   DOI   ScienceOn
6 M. J. Tummers, A. W. Hubner, "Hysteresis and Transition in Swirling Flames", Combustion and Flame, Vol. 156, No. 2, pp. 447-459, February 2009.   DOI   ScienceOn
7 K. Koyama, T. Sekiguchi, "The Measurement of the Electrical Conductivity of Seeded Flame Plasmas," Trans. on IEE Japan, Vol.87-6, No. 945, pp.1145-1151, 1987.
8 J. R. Fonseca, A. L. Tan, "Effects of Agricultural Fires on the Performance of Overhead Transmission Lines", IEEE Trans. Power Delivery, vol. 5, No. 4, pp. 687-693, 1990.   DOI   ScienceOn
9 J. A. Barnard, et al "Flame and Combustion Phenomena," 2nd ed., Chapman and Hall, pp. 142-185, 1985.
10 G. Gallet, et al "General Expression for Positive Switching Impulse Strength Valid up to Extra Long Air Gaps", IEEE Trans. PAS, vol. 94, No. 6, pp. 1989-1993, 1975.   DOI