• Title/Summary/Keyword: Flame Area

Search Result 277, Processing Time 0.025 seconds

Planar measurements of OH and $O_{2}$ number density in premixed $C_{3}$H$_{8}$O$_{2}$ flame using laser induced pre-dissociative fluorescence (레이저 유도 선해리 형광법(LIPE)을 이용한 화염내 OH 및 $O_{2}$ 분자의 2차원 농도 분포 측정)

  • Jin, Seong-Ho;Nam, Gi-Jung;Kim, Hoi-San;Chang, Nae-Kak;Park, Seung-Han;Kim, Ung;Park, Kyoung-Suk;Shim, Kyoung-Hoon;Kim, Gyung-Soo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.20 no.12
    • /
    • pp.4044-4052
    • /
    • 1996
  • Planar images of OH and $O_{2}$ with tunable KrF excimer laser which has a) 0.5 $cm^{-1}$ / linewidth, b) 0.5 nm tuning range, c) 150 mJ pulse energy, and d) 20 ns pulse width are obtained to determine spatial distributions of OH and $O_{2}$ in premixed $C_{3}$H$_{8}$ /O$_{2}$ flame. The technique is based on planar laser induced pre-dissociative fluorescence(PLIPF) in which collisional quenching is almost avoided because of the fast pre-dissociation. Dispersed LIPF spectra of OH and $O_{2}$ are also measured in a flame in order to confirm the excitation of single vibronic state of OH and $O_{2}$, OH and $O_{2}$ are excited on the P$_{2}$(8) line of the $A^{2}$.SIGMA.$^{+}$(v'= 3)-X$^{2}$.PI.(v'||'||'&'||'||'quot;= 0) band and R(17) line of the Schumann-Runge band B$^{3}$.SIGMA.$_{u}$ $^{[-10]}$ (v'= 0)- X$^{3}$.SIGMA.$_{g}$ $^{[-10]}$ (v'||'||'&'||'||'quot;= 6), respectively. Dispersed OH and $O_{2}$ spectra show an excellent agreement with simulated spectrum and previous works done by other group respectively. It is confirmed that OH widely distributed around flame front area than $O_{2}$.

An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires (랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구)

  • Park, Moon-Woo;Hong, Sung-Ho;Choi, Ki-Ok;Choi, Don-Mook;Kim, Soo-Jin
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.

Enhancing Design and Evaluating Mobility of Firefighting Chemical and Flame Protective Clothing for the National 119 Rescue Headquarters (중앙119구조본부 소방대원용 화학 보호복과 방열복의 동작적합성 평가 및 디자인 개선)

  • Syifa Salsabila;Do-Hee Kim;Joo-Young Lee
    • Fashion & Textile Research Journal
    • /
    • v.25 no.4
    • /
    • pp.520-533
    • /
    • 2023
  • The present study developed a test protocol for evaluating the mobility of firefighting chemical and flame personal protective equipment (PPE) for the National 119 Rescue Headquarters in Korea and suggested ergonomic design factors to improve their mobility and performance. Six types of PPE were employed, including three types for flame protective PPE (5 ~ 6 kg excluding the self-contained breathing apparatus), and three types for chemical and flame protective PPE (8 ~ 11 kg). These PPEs are used by the 119 Rescue firefighters. Three male firefighters (34.3 ± 1.2 y in age, 175 ± 8 cm in height, 81 ± 13 kg in body weight) participated in the mobility test and interview. A mobility test protocol consisting of 16 components (nine postures and seven motions including a dexterity test) along with a visibility test were developed based on pre-interviews and literature reviews. The findings indicated that the clothing microclimate humidity on the neck and chest exceeded 85%RH on average for all the six PPE conditions, with the chest area reaching as high as 98%RH. This high humidity caused fogging inside the visor and impaired visibility. The requirements for improving the PPE design in terms of mobility varied depending on whether it was the separated types or all-in-one types, particularly regarding the hood and gloves design. The findings of this study can be applied to improve the design of Level A_PPE for firefighters. The mobility test protocol and visibility test developed in this study can also be applied to other types of Level A impermeable PPE.

Studies on Combustion Synthesis of Carbon Nanotubes Using a Double-faced Wall Stagnation Flow Burner (양면정체유동버너를 이용한 탄소나노튜브 합성에 대한 연구)

  • Hong, Young-Taek;Woo, Sang-Kil;Kwon, Oh-Chae
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2154-2159
    • /
    • 2007
  • The potential of using a double-faced wall stagnation flow burner in mass production of carbon nanotubes was evaluated experimentally and computationally. With nitrogen-diluted premixed ethylene-air flames established on the Nickel-coated stainless steel double-faced wall, the propensities of carbon nanotube formation were experimentally determined using SEM and FE-TEM images and Raman spectroscopy, while the flame structure was computationally predicted using a 3-dimensional CFD code with a reduced reaction mechanism. The uniformity and yields of synthesized carbon nanotubes were evaluated in terms of the flame stretch rates. Results show substantial increase of area on the wall surface where uniform carbon nanotubes are synthesized with using the double-faced wall stagnation flow burner due to enhanced uniformity of temperature distribution along the wall surface and support the potential of using a double-faced wall stagnation flow burner in mass production of carbon nanotubes.

  • PDF

Numerical Analysis of Turbulent Combustion Flow in Scramjet Combustors (스크램제트 연소기 내의 난류 연소 유동 해석)

  • Choi, Jeong-Yeol;Won, Su-Hee;Jeung, In-Seuck
    • 한국연소학회:학술대회논문집
    • /
    • 2005.10a
    • /
    • pp.261-267
    • /
    • 2005
  • A comprehensive DES quality numerical analysis has been carried out for reacting flows in constant-area and divergent scramjet combustor configuration with and without a cavity. Transverse injection of hydrogen is considered over a broad range of injection pressure. The corresponding equivalence ratio of the overall fuel-air mixture ranges from 0.167 to 0.50. The work features detailed resolution of the flow and flame dynamics in the combustor, which was not typically available in most of the pervious studies. Much of the flow unsteadiness is related not only the cavity, but also to the intrinsic unsteadiness in the flowfield. The interactions between the unsteady flow and flame evolution may cause a large excursion of flow oscillation. The roles of the cavity, injection pressure, and heat release in determining the flow dynamics are examined systematically.

  • PDF

Reliance analysis for Mechanical characteristics of ACSR Transmission Line due to a Flame (화염에 의한 ACSR 송전선의 기계적 특성에 관한 신뢰성 분석)

  • Kim, Young-Dal;Shim, Jae-Myung;Kim, Jong-Suk
    • Proceedings of the KIEE Conference
    • /
    • 2004.11d
    • /
    • pp.71-76
    • /
    • 2004
  • This paper deals with the experimental results that apply to a new wire by an artificial flame-maker because it's difficult to directly analyze the characteristic of deterioration by a forest fire. Those results include tension load, extension rate and torsion number for a conductor. In addition, there's been an experiment and analysis about the mechanical characteristics of the wire of ACSR $48mm^2$ which was removed from Pohang area by a forest fire. Then, the database will be made to predict the state of deteriorated wires by a forest fire using those two data, and data necessary to diagnose the life state of an ACSR wire affected by a forest fire will be given.

  • PDF

Formation of MILD Combustion using Co-flow MILD Combustor (동축류 마일드 연소기를 적용한 마일드 연소 형성 연구)

  • Lee, Pil Hyong;Hwang, Sang Soon
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.8-16
    • /
    • 2017
  • MILD combustion was first developed to suppress thermal NOx formation in combustor for heating industrial furnaces. In this paper, the effect of co-flow MILD combustor geometry and operating conditions on the formation of MILD combustion was analyzed using 3 dimensional numerical simulation. The numerical simulations were carried out using ANSYS Fluent. The combustion and turbulence flow was modeled using the Eddy Dissipation Concept(EDC) model and realizable $k-{\varepsilon}$ model respectively. The results show that the high temperature region and average temperature decreased due to an increase in the air velocity and decrease the wall thickness of fuel nozzle. In particular, the MILD combustion flame was found to be stable with a combustion flame region at fuel velocity 10 m/s, air velocity 20 m/s, fuel nozzle thickness 1.0 mm, equivalence ratio 0.9, and outlet area ratio 40%.

Adsorption of Specific Organics in Water on GAC and Regeneration of GAC by Countercurrent Oxidative Reaction

  • Ryoo, Keon-Sang;Kim, Tae-Dong;Kim, Yoo-Hang
    • Bulletin of the Korean Chemical Society
    • /
    • v.23 no.6
    • /
    • pp.817-824
    • /
    • 2002
  • Granular activated carbon(GAC) is highly effective in removing organic compounds which are resistant to biological disintegration in wastewater treatment. However, GAC has reached its full adsorptive capacity, GAC needs to be regenerated before it can be used for a further adsorption cycle. Countercurrent oxidative reaction (COR) technique has been developed and evaluated for the regeneration of spent GAC. Various parameters such as flame temperature, the loss of carbon, destruction and removal efficiency (DRE) of organic compounds, surface area, surface structure, adsorptive capacity, etc. were examined to determine the performance of COR. The results of these tests showed that adosorptive capacity of regenerated GAC was completely recovered, the loss of carbon was controllable, flame temperature was high enough to insure complete destruction and removal $(\geq99.9999%)$ of specific organics of interest, polychlorinated biphenyls (PCBs), that are thermally stable, and on formation of toxic byproducts such as polychlorinated dibenzo-p-dioxins (PCDDs) or polychlorinated dibenzofurans (PCDFs) were detected during the regeneration process. The COR technique is environmentally benign, easy to use and less copital intensive than other available regeneration technologies.

Analysis of Combustion Instabilities in a 2-stage Duct System using Transfer Functions (전달함수를 이용한 2단 덕트 시스템에서의 연소불안정 해석)

  • Kim, Seonyeong;Kim, Daesik
    • Journal of ILASS-Korea
    • /
    • v.26 no.4
    • /
    • pp.182-188
    • /
    • 2021
  • In this paper, using a transfer function-based analytical model, major factors influencing the acoustics and combustion instability in a two-stage duct system composed of a nozzle and a combustor were derived and their quantitative effects were evaluated. From the acoustic analysis, it was confirmed that the change in reflection coefficient and mean flow could have a great influence on the instability growth rate, and the area ratio and speed of sound ratio between the nozzle and the combustor are also key parameters to determine combustion instability as well as flame transfer functions.

Comparison on the fire performance of additional insulation materials for improving the fire retardancy in engine-room of FRP vessel (FRP 선박 기관실 난연성 향상을 위한 추가 방열재의 화재성능비교)

  • Choi, Jung-Min;Um, Han-Chan;Jin, Young-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.38 no.9
    • /
    • pp.1150-1155
    • /
    • 2014
  • To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.