Abstract
To prevent the flame spread in FRP vessel in fire, the engine-room of the vessel should be constructed additionally with laminated fire-retardant resin over 3 times or equivalent insulation materials to former according to the relevant standard for FRP vessel structure. It is surveyed that insulation materials called 'Gel coat' are widely used in FRP fishing vessel, however, test method and its criteria for Gel coat are not clearly establish and have not been evaluated yet, while test method and criteria for fire-retardant resin and fire-retardant polyurethane composite are described in test standard for type-approval. In this study, 3 fire-retardant resins, 4 gel coats, 1 flame-retardant paint and 1 polyurethane composite were selected based on the survey and were evaluated according to both IMO FTP Code part 5 and flame-retardant test. When comparing based on CFE values from flame-spread test, average value for 4 gel coats were lower than that of 3 fire-retardant resins. As for flame-retardant test, there were no significant differences between fire-retardant resin and gel coat, based on charred area.
Keywords
FRP vessel; Fire-retardant resin; Gel coat; Flame-retardant paint; Fire safety;
Citations & Related Records
Times Cited By KSCI : 2  (Citation Analysis)
연도 인용수 순위
1 Korea Ship Safety Technology Authority, Cause analysis and its prevention plan for ship fires, p. 27, 2013 (in Korean).
2 W. J. Choi, "Flammability charateristics of unsaturated polyesters for FRP," Journal of Korean Institute of Fire Science and Engineering, vol. 12 no. 4, pp. 51-57, 1998 (in Korean).
3 K. W. Lee, K. E. Kim, and D. H. Lee, "Combustion characteristics of fiber reinforced plastic by cone calorimeter," Journal of Korean Institute of Fire Science and Engineering, vol. 18, no. 2, pp. 68-72, 2004 (in Korean).
4 H. J. Lee, B. J. Kang, C. J. Lee, K. H. Lee, G. S. Choi, H. U. Doo, M. J. Kim, H. H. Yeon, D. S. Kim, J. S. Lee, E. S. Kang, J. H. Kwark, H. G. Seo, and H. S. Yeo, "Study on fire safety characteristics and fire resistance structure of FRP vessel," Korea Ship Safety Technology Authority, p. 11, 2006 (in Korean).
5 Ministry of Oceans and Fisheries, "Standard of structure for FRP ship," Korea, Notification No. 2013-227, 2013. 9. 24 (in Korean).
6 International Maritime Organization, "International code for application of fire test procedures (2010 FTP Code)," United Kingdom, Resolution MSC.307(88), 2011. 2. 7.
7 Ministry of Oceans and Fisheries, "Standard of type-approval test and inspection of product for marine uses," Korea, Notification No. 2013-228, 2013. 9. 24 (in Korean).
8 Babrauskas and S. J. Grayson, Heat Release in Fires, Elselvier Science Publishing Co., New York, 1992
9 International Standard Organization, "Reaction-to-fire tests - spread of flame - part 2: Lateral spread on building and transport products in vertical configuration," Switzerland, ISO 5658-2:2006, 2006. 9. 18.
10 National Emergency Management Agency, "Standard of flame-retardant performance," Korea, Notification No. 2013-25, 2013. 7. 10 (in Korean).