• 제목/요약/키워드: Fixture

검색결과 723건 처리시간 0.033초

지대주 연결 형태와 골질에 따른 저작압이 임프란트 주위골내 응력분포에 미치는 영향 (Study on the stress distribution depending on the bone type and implant abutment connection by finite element analysis)

  • 박현수;임성빈;정진형;홍기석
    • Journal of Periodontal and Implant Science
    • /
    • 제36권2호
    • /
    • pp.531-554
    • /
    • 2006
  • Oral implants must fulfill certain criteria arising from special demands of function, which include biocompatibility, adequate mechanical strength, optimum soft and hard tissue integration, and transmission of functional forces to bone within physiological limits. And one of the critical elements influencing the long-term uncompromise functioning of oral implants is load distribution at the implant- bone interface, Factors that affect the load transfer at the bone-implant interface include the type of loading, material properties of the implant and prosthesis, implant geometry, surface structure, quality and quantity of the surrounding bone, and nature of the bone-implant interface. To understand the biomechanical behavior of dental implants, validation of stress and strain measurements is required. The finite element analysis (FEA) has been applied to the dental implant field to predict stress distribution patterns in the implant-bone interface by comparison of various implant designs. This method offers the advantage of solving complex structural problems by dividing them into smaller and simpler interrelated sections by using mathematical techniques. The purpose of this study was to evaluate the stresses induced around the implants in bone using FEA, A 3D FEA computer software (SOLIDWORKS 2004, DASSO SYSTEM, France) was used for the analysis of clinical simulations. Two types (external and internal) of implants of 4.1 mm diameter, 12.0 mm length were buried in 4 types of bone modeled. Vertical and oblique forces of lOON were applied on the center of the abutment, and the values of von Mises equivalent stress at the implant-bone interface were computed. The results showed that von Mises stresses at the marginal. bone were higher under oblique load than under vertical load, and the stresses were higher at the lingual marginal bone than at the buccal marginal bone under oblique load. Under vertical and oblique load, the stress in type I, II, III bone was found to be the highest at the marginal bone and the lowest at the bone around apical portions of implant. Higher stresses occurred at the top of the crestal region and lower stresses occurred near the tip of the implant with greater thickness of the cortical shell while high stresses surrounded the fixture apex for type N. The stresses in the crestal region were higher in Model 2 than in Model 1, the stresses near the tip of the implant were higher in Model 1 than Model 2, and Model 2 showed more effective stress distribution than Model.

구강내 임플랜트-지대주 연결부에서 치주질환관련 세균의 검출 (Detection of periodontal disease related bacteria from the implant-abutment interface in oral cavity)

  • 한명주;정재헌;김희중;국중기;유소영
    • 대한치과보철학회지
    • /
    • 제46권2호
    • /
    • pp.116-124
    • /
    • 2008
  • 문제 진술: 임플랜트 시스템은 임플랜트와 지대주 사이에서 빈 공간이 발생하여 세균의 저장소로서 작용하게 되어 임플랜트 주위 연조직에 염증반응을 야기할 수 있다. 목 적: 이 연구의 목적은 임플랜트-지대주 간극의 미세 누출에 관여하는 치주질환원인균으로 추정되는 Porpyromonas gingivalis, Prevotella intermedia, Tannerella forsythia, Treponema denticola, Aggregatibacter actinomycetemcomitans의 검출률을 조사하는 것이다. 연구재료 및 방법: 시료채취는 27명의 환자들에서 행하였고 소독된 페이퍼포인트를 이용하여 $1{\times}PBS$로 옮겼다. 치주질환원인균의 검출은 16 rDNA에 근거한 종특이적인 프라이머를 지닌 중합효소체인반응을 이용하였다. 결과: 임플랜트 고정체내에서의 Porphyromonas gingivalis와 Prevotella intermedia의 검출률은 59%와 82%였다. 환자의 임플랜트 연구에서는 Porphyromonas gingivalis와 Prevotella intermedia의 검출률은 44%와 82%였다. 환자혀에서의 Porphyromonas gingivalis와 Prevotella intermedia의 검출률은 82%와 82%였다. 결 론: 현재의 임플랜트 시스템은 임플랜트 내부의 세균 군집화와 미세누출을 안전하게 예방할 수 없다.

임플란트의 생존과 변연골 소실에 영향을 미치는 인자들 (Factors associated with the survival and marginal bone loss of dental implants: a 5-year retrospective study)

  • 송을락;이재관;엄흥식;박세환;장범석
    • 구강회복응용과학지
    • /
    • 제32권4호
    • /
    • pp.280-292
    • /
    • 2016
  • 목적: 이 연구의 목적은 임플란트의 생존율과 주위 변연골 수준을 후향적으로 평가하여, 술자의 임상적 경험을 포함한 요인들이 미치는 영향을 분석하고자 하였다. 연구 재료 및 방법: 2002년 1월부터 2009년 3월까지 강릉원주대학교치과병원 치주과에서 전공의가 2단계법으로 식립한 임플란트 중 5년 이상의 기록이 있는 146명의 420개 임플란트를 대상으로, 임플란트 탈락여부, 주위 골 소실량, 성별, 연령, 2형 당뇨, 흡연, 지대주 연결 형식, 표면 처리 방법, 직경, 식립 부위, 식립 당시 전공의 연차, 덮개 나사의 조기 노출, 보철학적 합병증, 동반된 골 이식 술식 등의 영향을 평가하였다. 결과: 최종 보철물 장착 후 5년간 누적생존율은 94.9% 이었다. 이원로지스틱회귀분석 결과, 흡연과 덮개 나사의 조기 노출이 실패율을 유의하게 증가시켰다. 다중회귀분석 결과, 흡연, 임플란트 지대주 연결 형식, 및 표면 처리 방법이 임플란트 주위 변연골 수준 변화에 유의한 영향을 주었다. 술자의 임상경험을 반영하기 위한 식립 당시의 전공의 수련 연차는 임플란트의 실패와 유의한 연관성은 보이지 않았다(P = 0.171). 결론: 흡연, 덮개 나사의 조기 노출, 지대주 연결 형식 및 표면 처리 방법이 임플란트의 성공과 유의한 상관관계를 보이는 것으로 생각된다.

임플랜트 지대주에 따른 나사 풀림의 연구 (THE INFLUENCE OF IMPLANT FIXTURE-ABUTMENT CONNECTION DESIGN ON SCREW LOOSENING)

  • 문양숙;박상원;방몽숙;양홍서;박하옥
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.174-184
    • /
    • 2006
  • Purpose: Current trend in implant dentistry is changing from external connection to internal connection. To evaluate the splinting of external and internal connection implant on screw loosening, 2-units prosthesis was fabricated with BioPlant $System^(R)$ of external connection type and Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. Material and Method: Experimental group is classified into three groups. 1) $G_1-EE$: 2-units prosthesis was fabricated with two Bioplant $System^(R)$ of external connection type. 2) $G_1-EI$: 2-units prosthesis was fabricated with one BioPlant $System^(R)$ of external connection type and one Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. 3) $G_1-II$: 2-units prosthesis was fabricated with two Lifecore STAGE-1 Single Stage Implant $System^(R)$ of internal connection type. In fabricating 2-units prosthesis, two hexed abutments are recommended when two implants are installed parallel, otherwise one hexed abutment is used on major occlusal force area and one nonhexed abutment is used on the other area. Since it is rare to find two implants being parallel, it is hard to fabricate prosthesis with passive adaptation using two hexed abutments. It is much more difficult to acquire passive adaptation when using hex abutment compared to nonhex abutment. To evaluate the influence of hexed and nonhexed abutment on screw loosening, 2-units prosthesis was fabricated with hexed and nonhexed abutment. Experimental group is classified into three groups. 1) $G_2-HH$: 2-units prosthesis was fabricated with two hexed abutments. 2) $G_2-HN$: 2-units prosthesis was fabricated with one hexed abutment and one nonhexed abutment. 3) $G_2-NN$: 2-units prosthesis was fabricated with two nonhexed abutments. Result: The results of comparing the detorque value after loading on a each prosthesis periodically are as follows. 1. In splinting group of external and internal connection implant, $G_1-II$ group demonstrated the biggest detorque value, followed by $G_1-EI$ group and $G_1-EE$ group. 2. There is no notable significance between external connection implant of $G_1-EI$ group and $G_1-EE$ group and also no significance between internal connection implant of $G_1-EI$ group and $G_1-II$ group. 3. $G_2-HH$ group showed higher detorque value than $G_2-HN\;and\;G_2-NN$ group. From the results, we can concluded that using both external connection and internal connection implant together is clinically acceptable and in order to acquire a good passive adaptation in fabricating 2-units implant prosthesis we can use two nonhexed abutments.

임플랜트 지대주 나사의 텅스텐 카바이드/탄소 코팅이 전하중에 미치는 영향에 관한 연구 (INFLUENCE OF TUNGSTEN CARBIDE/CARBON COATING ON THE PRELOAD OF IMPLANT ABUTMENT SCREWS)

  • 최진욱;정창모;전영찬;임장섭;정희찬;엄태관
    • 대한치과보철학회지
    • /
    • 제44권2호
    • /
    • pp.229-242
    • /
    • 2006
  • Statement of problem: In order to increase preload with reducing the friction coefficient, abutment screws coated with pure gold and Teflon as dry lubricant coatings have been introduced. But the reported data indicate that if screw repeated tightening and loosening cycle, an efficiency of increasing preload was decreased by screw surface wearing off. Purpose: This study was to evaluate the influence of tungsten carbide/carbon coating, which has superior hardness and frictional wear resistance, on the preload of abutment screws and the stability of coating surface after repeated closures. Material and method: The rotational values of abutment screws and the compressive forces between abutment and fixture were measured in implant systems with three different joint connections, one external butt joint and two internal cones. Moreover the stability and the alteration of coating surface were examined by comparison of the compressive force and the removable torque values during 10 consecutive trials, observation with scanning electron microscope and analyzed the elemental composition with energy dispersive x-ray spectroscopy Results and conclusion: 1. Application of coating resulted in significant increase of compressive force in all implant systems(P<.05). The increasing rate of compressive force by coating in external butt joint was gloater than those in internal cones (P<.05). 2. Coated screw showed the significant additional rotation compared to non-coated screw in all implant systems (P<.05). There were no significant differences in the increasing rate of rotation among implant systems (P>.05). 3. Removable torque values were greater with non-coated screw than that with coated screw (P<.05). 4. Coated screw showed insignificant variations in the compressive forces during 10 consecutive trials(P>.05) 5. After repeated trials, the surface layer of coated screw was maintained relatively well. However surface wearing and irregular titanium fragments were found in non-coated screw.

하우징 형태(Housing Type)로 제작된 배선 연결 커넥터의 안전성 평가에 관한 연구 (A Study on the Safety Estimation of Wiring Connection Connector Manufactured by Housing Type)

  • 최충석
    • 전기학회논문지P
    • /
    • 제59권4호
    • /
    • pp.462-466
    • /
    • 2010
  • The purpose of this study is to evaluate the safety of a wire connector fabricated for the effective installation of a lighting fixture including its contact resistance, insulation resistance, withstanding voltage characteristics, etc., and to provide the basis for the analysis and judgment of PL(Product Liability) dispute by presenting a damage pattern due to a general flame and overcurrent. This study applied the Korean Standard (KS) for the incombustibility test of the connector using a general flame and performed an overcurrent characteristics test of the connector using PCITS (Primary Current Injection Test System). The contact resistance of the housing connector was measured using a high resistance meter and the insulation resistance was measured using a multimeter. In addition, a supply voltage of AC 1,500V for testing the withstanding voltage characteristics was applied to both ends of the connector. Measurement was performed on 5 specimens and the measured values were used as a basis for judgment. Since the connector is fabricated in the form of a housing, it can be connected and separated easily and has a structure that allows no foreign material to enter. In addition, since it has a structure that allows wires to be connected only when their polarity is identical, any misconnection that may occur during installation can be prevented. When the incombustibility test was performed by applying a general flame to the connector, it showed outstanding incombustibility characteristics and the blade and blade holder connected to the housing remained firmly secured even after the insulation sheath (PVC) was completely destroyed by fire. In addition, the mechanism of the damaged connecting wire showed a comparatively uniform carbonization pattern and it was found that some residual melted insulation material was attached to both ends. In the accelerated life test (ALT) to which approximately 500% of the rated current was applied, the connector damage proceeded in the order of white smoke generation, wire separation, spark occurrence and carbonization. That is, it could be seen that the connector damaged by overcurrent lost its own metallic color with traces of discoloration and carbonization. The contact resistance of the connector at a normal state was 2.164mV/A on average. The contact resistance measured after the high temperature test was 3.258mV/A. In addition, the insulation resistance after the temperature test was completed was greater than $10G\Omega$ and the withstanding voltage test result showed that no insulation breakdown occurred to all specimens showing stable withstanding voltage and insulation resistance characteristics.

우주발사체용 복합재 산화제탱크 구조 강건성 검증을 위한 정하중 시험 (Static Load Test for Verification of Structural Robustness of Composite Oxidant Tank for Space Launch Vehicle)

  • 김현기;김성찬
    • 항공우주시스템공학회지
    • /
    • 제15권5호
    • /
    • pp.98-105
    • /
    • 2021
  • 본 연구에서는 우주발사체용 복합재 산화제탱크의 구조 강건성을 검증하기 위해 수행된 정하중시험 결과를 제시하였다. 먼저, 복합재 산화제탱크 정하중시험에 사용된 시험장비를 소개하고, 복합재 산화제탱크가 만족해야 하는 시험 요구도를 설명하였다. 그리고, 정하중 시험치구, 유압, 제어장비, 데이터획득장비로 구성되는 시험셋업 구성도를 제시하였고, 전단, 등가압축, 굽힘, 조합시험으로 구성된 복합재 산화제탱크 정하중 시험의 하중 프로파일을 제시하였다. 하중 제어의 결과로 시험하중 증가에 따른 각 하중부과기에서 입력하중과 출력하중 사이의 오차와 각 로드셀 A와 b 채널사이의 오차를 제시하여 본 시험의 신뢰성을 확인하였다. 정하중 시험 결과로, 각 시험에서 하중부과기의 하중은 허용 오차 범위 내에서 적절히 잘 제어되었으며, 시험시편도 요구 하중 내에서 파손이나 심각한 구조적 결함을 유발하는 좌굴은 발생하지 않는 것으로 확인되었다.

The long-term evaluation of the prognosis of implants with acid-etched surfaces sandblasted with alumina: a retrospective clinical study

  • Kim, Min-Joong;Yun, Pil-Young;Chang, Na-Hee;Kim, Young-Kyun
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제42권
    • /
    • pp.10.1-10.9
    • /
    • 2020
  • Background: The aim of this study was to evaluate the long-term clinical stability of implants with acid-etched surfaces sandblasted with alumina using retrospective analyses of the survival rate, success rate, primary and secondary stability, complications, and marginal bone loss of the implants. Methods: Patients who had implants placed (TS III SA, SS II SA, SS III SA, and U III SA) with SA surfaces from Osstem (Osstem Implant Co., Busan, Korea) at the Seoul National University Bundang Hospital, from January 2008 to December 2010 were selected for the study. Patients' medical records and radiographs (panorama, periapical view) were retrospectively analyzed to investigate sex, age, location of implantation, diameter, and length of the implants, initial and secondary stability, presence of bone grafting, types of bone grafting and membranes, early and delayed complications, marginal bone loss, and implant survival rate. Results: Ninety-six implants were placed in 45 patients. Five implants were removed during the follow-up period for a total survival rate of 94.8%. There were 14 cases of complications, including 6 cases of early complications and 8 cases of delayed complications. All five implants that failed to survive were included in the early complications. The survival of implants was significantly associated with the occurrence of complications and the absorption of bone greater than 1 mm within 1 year after prosthetic completion. In addition, the absorption of bone greater than 1 mm within 1 year after prosthetic completion was significantly associated with the occurrence of complications, primary stability, and implant placement method. Five cases that failed to survive were all included in the early complications criteria such as infection, failure of initial osseointegration, and early exposure of the fixture. Conclusions: Of the 96 cases, 5 implants failed resulting in a 94.8% survival rate. The failed implants were all cases of early complications such as infection, failure of initial osseointegration, and early exposure of the fixtures. Periimplantitis was mostly addressed through conservative and/or surgical treatment and resulted in very low prosthetic complications. Therefore, if preventive measures are taken to minimize initial complications, the results can be very stable.

편측 소수 잔존치 증례에서 CAD software를 활용한 planning 및 임플란트 서베이드 고정성 보철물을 이용한 국소의치 수복: 증례보고 (The use of implant surveyed fixed prosthesis for removable partial denture with a few unilateral remaining teeth: A case report)

  • 박정근;김종은;박지만;김지환;심준성
    • 대한치과보철학회지
    • /
    • 제57권3호
    • /
    • pp.254-262
    • /
    • 2019
  • 임플란트에 대한 급여의 확대로 임플란트의 지지를 받는 서베이드 고정성 보철물 제작 후 국소의치로 수복하는 증례에 대한 관심이 증가하고 있다. 이러한 증례의 예지성 있는 결과를 위해서 국소의치의 기본적인 설계 원칙과 잔존 치조골을 동시에 고려한 임플란트 계획수립이 필요하다. 본 증례는 편측 소수 잔존치를 가진 67세 남자 환자로 국민건강보험의 적용을 받을 수 있는 치료를 희망했다. CAD 소프트웨어를 활용하여 임시의치의 교합면, 국소의치의 기본적인 설계 원칙 및 흡수된 치조제를 모두 고려한 임플란트의 식립 위치를 결정하였다. 치료 결과 상악 및 하악 의치의 안정성 및 유지력이 적절하게 확보되었다. 본 증례는 임플란트 고정성 보철물 제작 시 국소의치의 기본적인 원칙과 흡수된 치조제를 모두 고려하기 위해 디지털 기술을 진단 및 치료에 활용하였고, 안정적인 결과를 얻었기에 이를 보고하고자 한다.

한국형 건축물 가스 배관의 내진 고정장치에 관한 연구 (A Study on Seismic Restraint of Korean Type Building Gas Piping)

  • 임건태;임상호
    • 산업진흥연구
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2019
  • 본 연구는 아파트, 빌딩 등의 건축물에 설치되는 가스배관의 고정장치에 관한 기술로서, 가스배관이 사방으로 완충작용을 하도록 하우징의 내측에 고정됨으로써, 지진이나 충격에 의한 진동을 완화시켜 가스배관의 손상 및 파손을 방지함에 따라 지진 및 가스배관의 파손에 의한 피해를 최소화할 수 있는 가스배관의 내진 고정장치에 관한 기술분야가 개시된다. 건축물의 벽면 또는 벽면에 설치된 브라켓에 가스배관을 고정하는 장치에 있어서, 벽면 또는 브라켓에 하부가 결합되는 하우징과 하우징의 내측에 삽입되어 결합되고, 가스배관이 내측에 관통되어 고정되며, 가스배관을 사방으로 탄성지지하는 복수 개의 요철부가 형성되는 제1판스프링을 포함하고, 하우징의 전면 또는 후면에 나사결합되고, 하부가 제1판스프링의 일측말단과 타측말단에 각각 결합되어 회전됨으로써 제1판스프링의 탄성력을 조절하는 한쌍의 제1조절나사를 더 포함하여 구성되는 것을 특징으로 하는 가스배관의 내진 고정장치이다. 본 연구를 통하여 지진이나 충격에 의한 가스배관의 손상 및 파손을 최소화할 수 있는 효과를 얻을 수 있다.