• 제목/요약/키워드: Fixture

검색결과 725건 처리시간 0.028초

치과 임플란트 고정체의 여러 가지 제조공정과정에 따른 표면특성 (Surface Characteristics of Dental Implant Fixture with Various Manufacturing Process)

  • 정용훈;문영필;이충환;유진우;최한철
    • 한국표면공학회지
    • /
    • 제43권1호
    • /
    • pp.17-24
    • /
    • 2010
  • In this study, surface characteristics of dental implant fixture with various manufacturing process have been researched using electrochemical methods. The dental implant fixture was selected with 5 steps by cleaning, surface treatment and sterilization with same size and screw structure; the 1st step-machined surface, 2nd step-cleaned by thinner and prosol solution, 3th step-surface treated by RBM (resorbable blasting media) method, 4th step-cleaned and dried, 5th step-sterilized by gamma-ray. The electrochemical behavior of dental implant fixture has been evaluated by using potentiostat (EG&G Co, 2273A) in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion surface was observed using field-emission scanning electron microscopy (FE-SEM) and energy dispersive x-ray spectroscopy (EDS). The step 5 sample showed the cleaner and rougher surface than step 3 sample. The step 5 sample of implant fixture treated by RBM and gamma sterilization showed the low corrosion current density compared to others. Especially, the step 3 sample of implant fixture treated by RBM was presented the lowest value of corrosion resistance and the highest value of corrosion current density. The step 3 sample showed the low value of polarization resistance compared to other samples. In conclusion, the implant fixture treated with RBM and gamma sterilization has the higher corrosion resistance, and corrosion resistance depends on the step of manufacturing process.

임플랜트 고정체-지대주 연결부의 형태와 직경이 임플랜트의 기계적 실패에 미치는 영향 (Effect of morphology and diameter of implant fixture-abutment connection on mechanical failure of implants)

  • 윤보혁;신현모;윤미정;허중보;정창모;강은숙
    • 대한치과의사협회지
    • /
    • 제53권9호
    • /
    • pp.644-655
    • /
    • 2015
  • Purpose: This study was conducted to evaluate the effect of the fixture abutment connection type and diameter on the screw joint stability in external butt joint for 2nd surgery and internal cone connected type implant system for 1st and 2nd surgery using ultimate fracture strength. Materials and Methods: USII system, SSII system and GSII system of Osstem Implant were used. Each system used the fixture with two different diameters and cement-retained abutments, and tungsten carbide / carbon coated abutment screws were used. Disc shaped stainless steel metal tube was attached using resin-based temporary cement. The experimental group was divided into seven subgroups, including the platform switching shaped specimen that uses a regular abutment in the fixture with a wide diameter in USII system. A static load was increased to the metal tube at 5mm deviated point from the implant central axis until it reached the compression bending strength at a rate of 1mm/min. Then the deformations and patterns of fracture in threaded connection were compared. Results and Conclusion: 1. In the comparison between the Regular diameter, compression bending strength of SSII system was higher than USII system and GSII system. There was no significant difference between USII system and GSII system. 2. In the comparison between wide diameter, compression bending strength was increased in the order of GSII system, USII system, and SSII system. 3. In comparison between the implant diameter, compression bending strength of the wide diameter was greater than the regular diameter in any system(P<0.05). 4. There was no significant difference between the platform switching (III group) and the regular diameter (I group) in USII system. 5. In USII system, fracture of abutment screw and deformation of both fixture and abutment were observed in I, II and III subgroups. 6. Failure pattern of SSII system, which was the fracture of abutment screw and deformation of the abutment and fixture, was observed in both IV and V subgroups. Fracture of some fixtures was observed in subgroup V. 7. Failure pattern of GSII system, which was the fracture of the abutment screw and deformation of the fixture and the abutment, was observed in both VI and VII subgroups. Apart from other subgroups, subgroup VII demonstrated no bending neither the fracture at the top of the fixture. The compressive deformation of internal slope in the fixture was the only thing observed in subgroup VII.

형상공간 접근 방식에 기반한 모듈식 고정쇠의 적재가능성 분석 (Loadability Analysis of Modular Fixtures based on a Configuration Space Approach)

  • 유견아
    • 제어로봇시스템학회논문지
    • /
    • 제9권5호
    • /
    • pp.398-406
    • /
    • 2003
  • In modular fixturing systems, a given part or a subassembly is fixed by placing fixture elements such as locators and clamps adequately on a plate with a lattice of holes. It is known that the minimal number of point contacts to restrict translational and rotational motions on a plane is four and the type of three locators and a clamp(3L/1C) is the minimal future. Brost and Goldberg developed the complete algorithm to automatically synthesize 3L/1C types of fixtures which satisfy the condition of form closure. Due to the nature of the fixture, the clearance between the fixture and the part is extremely small. It is hard to load the part repeatedly and accurately for human as well as for robot. However the condition of loadability has not been taken into account in the B&G algorithm. In this paper, a new method to decide a given fixture to be loadable by using configuration space is proposed. A method to plan for a part to be loaded by using compliance safely even in the presence of control and sensing uncertainty is proposed is well.

무대방송 조명 등기구에서의 조도 실측과 시뮬레이션 조도 측정 비교 연구 (A Study on the Comparison of Illuminance Simulations and Measured Values of Compare a Stage and Broadcasting Lighting Fixture)

  • 이장원;임지원;한석우
    • 한국인터넷방송통신학회논문지
    • /
    • 제11권2호
    • /
    • pp.145-152
    • /
    • 2011
  • 무대방송 프레즈널 조명기와 플라노 컨벡스 조명기의 측정값과 시뮬레이션 측정값의 조도를 측정하기 위하여 대전보건대학 스튜디오 안에서 전동바턴 시스템의 조명 등기구를 설치하였다. 프레즈널 조명기와 플라노 컨벡스 조명기의 조도 시뮬레이션 값과 측정값을 비교하여 조도 오차가 얼마나 생기는지에 대하여 비교하였다. 비교한 결과 시뮬레이션 프레즈널 조명기와 플라노 컨벡스 조명기의 측정값은 39.7~250.6Lux 차이가 있다. 그리고 프레즈널 조명기와 플라노 컨벡스 조명기의 실측값의 조도값의 차이는 92.84~157.35Lux 차이가 있다.

3점 방식 불평형량 측정법에서의 오차보상 기법 (Error-compensating Techniques in 3-Point Weighing Method to Measure Unbalance Properties)

  • 이선표
    • 한국정밀공학회지
    • /
    • 제23권11호
    • /
    • pp.42-49
    • /
    • 2006
  • In this paper error-compensating techniques in three-point weighing method to precisely measure unbalance properties such as center of gravity and unbalance moment. In the conventional static methods, 1) fixture-errors, 2) effects of the contact between the fixture and the load scales, and 3) side effect due to the lateral frictional forces acting on the contact points between the fixture and the load scales are the major factors that lead to measurement errors. The proposed error-compensating method perfectly eliminates both the fixture-error and the contact-error simultaneously by manipulating the three measured reaction forces at three different angular locations. Also the friction-error is calibrated by comparing the sum of three reactions with the actual mass of the specimen. A set of measurement is performed using the same measuring system as Lee's, and a comparison of the results from the convectional, Lee's, and the proposed method is provided. The results show that the proposed method effectively compensates the errors listed above.

필라멘트 와인딩 공법으로 제조된 복합재료 NOL Ring 시험편의 최적 인장강도의 평가법에 관한 연구 -풍력발전용 복합재료 터빈블레이드 제조 및 평가를 목적으로- (A Study on the Evaluation Method for optimal Tensile NOL Ring Composite Specimen Manufactured by Filament Winding Process-to manufacture and elvaluate the composite turbine blade of wind generator system-)

  • 배창원;권순철;임철문;엄수현;김윤해
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제25권1호
    • /
    • pp.87-94
    • /
    • 2001
  • Filament winding process is a comparatively simple operation in which continuous reinforcements in the form of roving are wound over a rotating mandrel. And now it is well established as a versatile method for storage tanks and pipe for the chemical and other industries. In this study, tensile strength of a filament wound ring specimens were evaluated by split disk test fixture and dress disk test fixture. The results obtained from experiments were compared with the theoretical values obtained by the rule of mixture. And the purpose of this paper is to suggest an appropriate test method for the evaluation of tensile properties of filament wound structures. The tensile strength of a ring specimens tested by the dress disk test showed better agreement with the theoretical values than of a ring specimen tested by the split disk test because the stress concentration in edges of s split disk test fixture is more severe than the that of dress disk test fixture. The results showed that the tensile strength of a ring specimen was influenced by the geometry of test fixture, the continuity of fibers, fiber-tension, fiber-end and stress concentration in specimen.

  • PDF

Implant 보철물 access hole의 깊이에 관한 연구 (RELALTIONSHIP BETWEEN THE DEPTH ACCESS HOLE AND PROSTHETIC COMPONENTS IN SCREW RETAINED IMPLANTS)

  • 고석민;변태희;이재봉
    • 대한치과보철학회지
    • /
    • 제40권4호
    • /
    • pp.374-385
    • /
    • 2002
  • A total of 605 implant fixture prosthesis delivered by 3 clinics and 2 laboratories were examined in this study, The object of this study was to determine the proper length of screw head. The depth of access hole were measured and compared to the type of fixture, abutment, gold screw and prosthesis. The results were as follows : 1 The average number of fixtures per patient were 2.97. 2. The number of fixture installed in the upper posterior area are 327(55.56 %), the upper posterior area 171 (28.25%). 3. The depth of access hole is 4.23 mm in shallow area, and 5.46 mm in deep area and the differences were 1.23 mm. 4. The average depth of the aceess hole of the UCLA abutment were 5.02 mm. 5. The number of 4-5 mm access hole depth were 60(22.39%) in abutment screw level and the number of 4-5 mm depth in fixture level were 101 (29.19%). 6. In the shape of screw head, hexed type were 576(95.21%), slotted type were 29(4.79%).

임플란트 고정체와 지대주의 체결방식에 따른 스크류 풀림토크에 관한연구 (A Study on the Screw Loosening Torque According to the Type of Tightening the Implant Fixture and Abutment)

  • 박수철;김홍식;함성원
    • 대한치과기공학회지
    • /
    • 제35권3호
    • /
    • pp.201-207
    • /
    • 2013
  • Purpose: In this study, the loosening torque test was conducted with three implant products that are produced, approved and sold in Korea, which are manufactured in different fixture and abutment tightening methods (internal submerged type, internal morse taper type, and external type) to examine the loosening torque of the screw according to the method of tightening the implant fixture and abutment. Methods: In the loosening torque test, the three types of fixtures and abutments with different tightening methods were tightened by rotating them clockwise with a $30N{\cdot}cm$ force using a driver equipped with an electric torque meter. The results of the test are as follows. Results: The loosening torque values of the internal submerged type, internal morse taper type and external type implants were $24.10{\pm}0.742N{\cdot}cm$, $29.10{\pm}1.710N{\cdot}cm$, and $26.60{\times}1.636N{\cdot}cm$, respectively. Conclusion: The screw loosening torque values of the three fixture and abutment tightening methods were analyzed via Kruskal Wallis test layout, and they were significantly different (p<0.05).

학교건축(學校建築)의 세면기(洗面器) 및 음용수(飮用水) 시설(施設) 계획(計劃)에 관한 연구(硏究) -세면기와 음수대의 적정 수 산정을 중심으로- (A Study on planning lavatories and drinking fountains required in school -focused on the optimal numbers-)

  • 이화룡;홍승오
    • 교육시설
    • /
    • 제12권1호
    • /
    • pp.14-28
    • /
    • 2005
  • Functional school planning has long been considered a fundamental concept of school design. However. in planning educational facilities, it is also important to include the dimensions of comfort, convenience and healthfulness. The school lavatories and drinking fountains are one of most crucial elements for the recent changing face in healthful school design, but the number of lavatories and drinking fountains in most schools may not be sufficient to meet current needs. This study aims to suggest a guideline in designing school sanitary fixture and propose the optimal number of lavatories and drinking fountains regarded to age and sex. The survey is conducted through questionnaires collected from 998 respondents including 300 teachers In ChungNam province. Based on the results of the survey and a formulae, it is suggested that the number of lavatories be required by ratio of 30 boys per unit fixture and 22 girls per unit fixture in the elementary, middle and high school. It is also suggested that the number of drinking fountains be required by ratio of 65 students per unit fixture. The formulae proposed in this paper can be used for other plumbing fixtures required in school facilities.

사무소 건물의 급수배관경 산정을 위한 동시사용유량에 관한 연구 (The evaluation of the simultaneous flow rate for sizing the water supply piping in the office building)

  • 이용화
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.511-517
    • /
    • 1999
  • Determining the simultaneous flow rate in any particular section of piping is the important step in order to determine the size of water supply piping. Now we are using the diversity curve of common water closet in order to determine the simultaneous flow rate of water supply piping, but there is a difference between a determined flow rate of general water closet and that of water closet for water saving. This study aims to find out the fixture unit of a flush valve type water closet for water saving in office building, and to determine the correlation between the fixture units and peak flow rates on the basis of the probability theory. A flush valve type water closet for water saving that have a 7.5 second duration of flush operation with an average design flow rate 72 $\ell$/fin was considered. Simulation results indicate that the number 5 is shown to be reasonable to the fixture unit of water closet for water saving. And the design can be undersized considerably with the revised diversity curves using modified fixture unit.

  • PDF