DOI QR코드

DOI QR Code

A Study on the Screw Loosening Torque According to the Type of Tightening the Implant Fixture and Abutment

임플란트 고정체와 지대주의 체결방식에 따른 스크류 풀림토크에 관한연구

  • Park, Soo-Chul (Department of Dental Technology, Gimcheon University) ;
  • Kim, Hong-Sik (Department of Dental Technology, Gimcheon University) ;
  • Ham, Sung-Won (Department of Chemical Engineering, Kyungil University)
  • 박수철 (김천대학교 치기공학과) ;
  • 김홍식 (김천대학교 치기공학과) ;
  • 함성원 (경일대학교 화학공학과)
  • Received : 2013.07.27
  • Accepted : 2013.09.13
  • Published : 2013.09.30

Abstract

Purpose: In this study, the loosening torque test was conducted with three implant products that are produced, approved and sold in Korea, which are manufactured in different fixture and abutment tightening methods (internal submerged type, internal morse taper type, and external type) to examine the loosening torque of the screw according to the method of tightening the implant fixture and abutment. Methods: In the loosening torque test, the three types of fixtures and abutments with different tightening methods were tightened by rotating them clockwise with a $30N{\cdot}cm$ force using a driver equipped with an electric torque meter. The results of the test are as follows. Results: The loosening torque values of the internal submerged type, internal morse taper type and external type implants were $24.10{\pm}0.742N{\cdot}cm$, $29.10{\pm}1.710N{\cdot}cm$, and $26.60{\times}1.636N{\cdot}cm$, respectively. Conclusion: The screw loosening torque values of the three fixture and abutment tightening methods were analyzed via Kruskal Wallis test layout, and they were significantly different (p<0.05).

Keywords

References

  1. Carlson B, Carlsson GE. Prosthodontic complications in osseointegrated dental implant treatment. J Implant Dentistry, 3(4), 264, 1994.
  2. Ekfeldt A. Carlsson GE, Borjesson G. Clinical evaluation of single-tooth restorations supported by osseointegrated implants: a retrospective study. Int J Oral Maxillofac Implants, 9(2), 179-183, 1994.
  3. Eom TG, Suh SW, Jeon GR, Shin JW, Jeong CM. Effect of Tightening Torque on Abutment- Fixture Joint Stability using 3-Dimensional Finite Element Analysis. J Korean Acad Prosthodont, 47(2), 125-135, 2009. https://doi.org/10.4047/jkap.2009.47.2.125
  4. Hemmings KW, Schmitt A, Zarb GA. Complications and maintenance requirements for fixed prostheses and overdentures in the edentulous mandible: a 5-year report. Int J Oral Maxillofac Implants, 9(2), 191-196, 1994.
  5. Holmes DC, William RG, Vijay KG, John CK. Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis. Int J Oral Maxillofac Implants, 7(4), 450-458, 1992.
  6. Jamiyandorj O, Kim JH, Kim MS, Park YB, Shim JS. Comparison of removal torque between prefabricated and customized abutment screw. J Korean Acad Prosthodont, 50(4), 243-248, 2012. https://doi.org/10.4047/jkap.2012.50.4.243
  7. Jemt T, Pattersson P. A 3-year follow-up study on single implant treatment. J Dent, 21(4), 203-208, 1993. https://doi.org/10.1016/0300-5712(93)90127-C
  8. Jorn'eus L, Jemt T, Carlsson L. Loads and designs of screw joints for single crowns supported by osseointegrated implants. Int J Oral Maxillofac Implants, 7(3), 353-359, 1992.
  9. Kallus T, Bressing C, Odont D. Loose gold screws frequently occur in full-arch fixed prostheses supported by osseointegrated implants after 5 years. Int J Oral Maxillofac Implants, 9(2), 169-178, 1994.
  10. Koak JY, Heo SJ, Chang IT, Yim SH, Lee JY, Lee KR. The study on the removal torque of the diamond like carbon coated titanium abutment screws. J Korean Acad Prosthodont, 41(2), 128-135, 2003.
  11. Lee CJ, Yang SE, Kim SG. Evaluation of reverse torque value of abutment screws on CAD/CAM custom-made implant abutments. J Korean Acad Prosthodont, 50(2), 128-134, 2012. https://doi.org/10.4047/jkap.2012.50.2.128
  12. Park JK, Jeong CM, Jeon YC, Yoon JH. Influence of tungsten carbide/carbon coating of implantabutment screw on screw loosening. J Korean Acad Prosthodont, 46(2), 137-147, 2008.
  13. Park SC, Choi SM, Kang JH. Corrosion Resistance Evaluation in the Co-Cr Alloys for the Full and Removable Partial Denture Metal Frameworks and the Porcelain-fused-tometal Crown. J Korean Acad dental Technology, 34(3), 237-245, 2012. https://doi.org/10.14347/kadt.2012.34.3.237
  14. Sakong J, Park SC. Concentration of elemental ions released from non-precious dental casting alloys. J Korean Acad dental Technology, 35 (1), 1-18, 2013. https://doi.org/10.14347/kadt.2013.35.1.001
  15. The performance and stability of the dental implant assessment tests guidelines. Korea Food & Drug Administration, 2006.

Cited by

  1. Loosening analysis for fastening screw of automotive door trim parts vol.17, pp.4, 2016, https://doi.org/10.1007/s12239-016-0066-1