• 제목/요약/키워드: Fixing Force

검색결과 73건 처리시간 0.026초

3차원 유한요소법을 이용한 배선용 차단기의 순시 트립부 해석 (Analysis of Instant Trip Unit Using 3D Finite Element Method)

  • 홍승표;김길수;임종득;박진영;조현길
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.712-714
    • /
    • 2002
  • Through the Standard of UL489, the Adjustable Type Instant Trip Unit should NO trip at 80% of each current from $5{\times}In$ to $10{\times}In$ and trip 130% of those. In this paper, we obtain the attraction force between Fixing Magnet and Moving Armature. we simulated the modelling by 3D Finite Element Method. With values of experiment and simulated values, in this paper, we show the method for set up the process of designing Instant spring.

  • PDF

과적차량 방지를 위한 유비쿼터스도로에 관한 연구 (A Study On Ubiquitous Road For Prevention Of The Overweight Vehicles)

  • 조병완;윤광원;박정훈;김헌;오세영;신병철
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2008년도 정기 학술대회
    • /
    • pp.548-553
    • /
    • 2008
  • Overloaded Vehicles are one of biggest of hazard in durability decrease of roads and bridges. Thus, regulation was put in force about overloaded vehicles to reserve this problem. However, existing system had many problems. For these reasons, this paper presents solutions of U-intelligent overload vehicles regulation system based on manless and wireless for fixing of problems of existing system and construction of ITS. With this in mind, we studied about composition method of system, applications of USN, design of system controller, WCDMA/ HSDPA, etc in this paper.

  • PDF

휠로더 엔진 밸브 커버 볼트의 파손 원인 규명 및 개선 (A study on the fatigue fracture of engine valve cover bolt for a wheel loader)

  • 이군희;주원호;김동해;배종국
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1218-1222
    • /
    • 2006
  • The bolts fixing the valve cover to the engine were often reported to be failed in a wheel loader model. Recently this failures were continually repeated in the specified equipment. In order to identify the fatigue fractures of the bolts, various vibration tests were carried out. From these tests, it was found out that the failure was due to the resonance between the excitation force of engine and the transverse mode of engine valve cover. So, the several modifications for the bolts were considered to avoid the resonance. Finally, the bolt failure problem was clearly resolved.

  • PDF

U-중차량 무인과적단속시스템 구축방안에 대한 연구 (A Study On Development of U- Intelligent Overload Regulation System)

  • 조병완;박승국;김도근;윤석민;박정훈;강성민
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2007년도 정기 학술대회 논문집
    • /
    • pp.831-836
    • /
    • 2007
  • Overloaded Vehicles are one of biggest of hazard in durability decrease of roads and bridges. Thus, regulation was put in force about overloaded vehicles to reserve this problem. However, existing system had many problems. For these reasons, this paper presents solutions of U-intelligent overload vehicles regulation system based on manless and wireless for fixing of problems of existing system and construction of ITS. With this in mind, we studied about composition method of system. applications of USN, design of system controller, WCDMA/HSDPA, etc in this paper.

  • PDF

배선용 차단기 순시 가조정 트립부 개발에 관한 연구 (Researchs for the Development of MCCB adjustable Instant Trip Unit)

  • 송중천;유만종;김길수;강종성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.354-356
    • /
    • 1999
  • Through the Standard of MCCB, the Adjustable Type Instant Trip Unit should NO trip at -20% of each current from $5{\times}In$ to $10{\times}In$ and trip +20% of those. In this paper, we obtain the attraction force between Fixing Magnet and Moving Armature. So we first made some samples. do experiments of weight, and simulated the modelling by 3D Maxwell S/W. With values of experiment and simulated values, we do design instant trip springs by using the ADAMS S/W of kinematic simulation. Finally we product the 250A Adjustable Instant Trip Unit, and it is very useful to our customers.

  • PDF

철도용 사장교의 주탑 케이블 정착부에 관한 연구 (A Study on Pylon Cable Anchor System in Cable-Stayed Railway Bridge)

  • 한성관;공병승
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.565-580
    • /
    • 2006
  • Set in constant increase and period current of lively technical development of railroad use and construction of cable stayed bridge railway bridge, one of bridge form of most suitable that think side police officer and the material enemy of bridge that use long rail, is increasing laying stress on the foreign countries. Main tower fixing department of this cable stayed bridge is consisted of main tower flange that support bearing plate, bay ring plate bearing plate, support end rib and diaphragm etc, as stress transmission mechanic that tensility of cable socket into normal force of main tower, and is used this time. These structural elements is very complex the structure and direction of load delivered from socket specially calbe particularly be different, and need FEM analysis that use Thick Shell element for suitable arrangement of mutual stress flowing grasping and absence that follow hereupon because all of the each support plate angle that suport this differ.

  • PDF

CLT-콘크리트 합성 거동을 위한 전단 연결재 부재 실험과 해석 연구 (Experimental and Analytical Study of Shear Connectors for the CLT-Concrete Composite Floor System)

  • 박아론;이기학
    • 한국공간구조학회논문집
    • /
    • 제19권1호
    • /
    • pp.65-73
    • /
    • 2019
  • This paper assesses the structural performance (force-slip response, slip modulus, and failure modes) of a CLT-concrete composite by conducting fifteen push-out test specimens. In addition, non-linear 3D finite element analysis was also developed to simulate the load-slip behavior of the CLT-concrete specimens under shear load. All 15 test specimens simulating the effect of concrete thickness, connection angle and penetration depth with four different shear connector types were built and tested to evaluate the flexural performance. Experimental results show that the maximum shear capacity for the composite action is obtained when the fixing angle is $90^{\circ}$ and the penetration depth of 95mm for SC normal screw was used to achieve ductile failure compared to other shear connectors.

파워인덕터 생산용 표면 UV 인쇄장치 성능 연구 (A Study on the Performance of Surface UV Printing Device for Power Indicator Production)

  • 이현무;안소미;안성민;서정환;정병조;강성린
    • 미래기술융합논문지
    • /
    • 제2권4호
    • /
    • pp.1-6
    • /
    • 2023
  • 파워인덕터 생산용 표면 UV 인쇄장치 성능 연구는 원기둥 자석의 자력 형성이 상, 하로 형성되게 제작함으로써 제품 고정 시 제품이 뒤집히거나, 세워지는 현상을 방지하는 기술을 적용하여 인쇄 진행 시 품질 소모성 자재(제판, Squeegee)의 파손을 방지하고, 인쇄 품질을 향상시킬 수 있다. 자력의 방향을 바꾼 원기둥 자석의 개발로 파우더 압축으로 제작한 메탈 소재 제품에 대한 고정 방법이 안정화 되어 소형 제품에 대한 생산 능력이 증대할 것이다. 최종적으로 원기둥 자석을 활용한 파워인덕터 표면 UV 인쇄 장치를 연구함으로써, 기존 작업 진행하던 스프레이, Deeping 방식과 차별성을 둘 수 있고, 생산량이 크게 향상될 것이며 결과적으로는 인원 감축으로 원가절감 및 경쟁력 있는 제품 생산을 할 수 있을 것이다.

한국형 건축물 가스 배관의 내진 고정장치에 관한 연구 (A Study on Seismic Restraint of Korean Type Building Gas Piping)

  • 임건태;임상호
    • 산업진흥연구
    • /
    • 제4권1호
    • /
    • pp.11-20
    • /
    • 2019
  • 본 연구는 아파트, 빌딩 등의 건축물에 설치되는 가스배관의 고정장치에 관한 기술로서, 가스배관이 사방으로 완충작용을 하도록 하우징의 내측에 고정됨으로써, 지진이나 충격에 의한 진동을 완화시켜 가스배관의 손상 및 파손을 방지함에 따라 지진 및 가스배관의 파손에 의한 피해를 최소화할 수 있는 가스배관의 내진 고정장치에 관한 기술분야가 개시된다. 건축물의 벽면 또는 벽면에 설치된 브라켓에 가스배관을 고정하는 장치에 있어서, 벽면 또는 브라켓에 하부가 결합되는 하우징과 하우징의 내측에 삽입되어 결합되고, 가스배관이 내측에 관통되어 고정되며, 가스배관을 사방으로 탄성지지하는 복수 개의 요철부가 형성되는 제1판스프링을 포함하고, 하우징의 전면 또는 후면에 나사결합되고, 하부가 제1판스프링의 일측말단과 타측말단에 각각 결합되어 회전됨으로써 제1판스프링의 탄성력을 조절하는 한쌍의 제1조절나사를 더 포함하여 구성되는 것을 특징으로 하는 가스배관의 내진 고정장치이다. 본 연구를 통하여 지진이나 충격에 의한 가스배관의 손상 및 파손을 최소화할 수 있는 효과를 얻을 수 있다.

선박용 디젤엔진의 탄성지지계 설계에 관한 연구 (A Study on the Design of Resilient Mounting Systems for Marine Diesel Engines)

  • 김성춘;이돈출;김의간
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제18권5호
    • /
    • pp.56-67
    • /
    • 1994
  • The installation methods of diesel engines in ships would be largely classified into two groups : one is the direct mounting system fixing engine directly into double bottom of the hull, and the other is the resilient mounting system having vibration absorbers between engine and ship body such as rubber plate to prevent shocks or vibration transmission. The direct mounting system is generally used for large-sized low speed diesel engines, because the resilient mounting system has difficulties in reducing the natural frequency of engine itself under normal speed. On the contrary, the resilient mounting system is often used for medium or high speed engines for marine propulsion and generator that have light weight and high revolution speed. Recently, it is even applied to engines having relatively low speed(300-400rpm) for fishing boats. Although many researches for the resilient mounting system have been carried out, many problems in applying these results directly to marine vessels because most of these have been used for automobiles. Up to now we have had to depend on the professional foreign company in design and the supply of parts for the resilient mounting system of marinediesel engines utterly. In preseut study, the exciting forces of engines effecting to resilient mounting were examined, and patterns of vibration and evaluation procedure for force transmission from resilient mounting to the body of hull were established. Also, these results were applied to the analysis of free and forced vibration for the rubber-type resilient mounting systems of marine diesel engines. Besides, after changing the various design parameters, such as locations, angles, dynamic characteristics and the number of resilient mountings, the influences on resilient mounting system were also examined.

  • PDF