• Title/Summary/Keyword: Fixed-two methods

Search Result 716, Processing Time 0.025 seconds

WEAK AND STRONG CONVERGENCE THEOREMS FOR THE MODIFIED ISHIKAWA ITERATION FOR TWO HYBRID MULTIVALUED MAPPINGS IN HILBERT SPACES

  • Cholamjiak, Watcharaporn;Chutibutr, Natchaphan;Weerakham, Siwanat
    • Communications of the Korean Mathematical Society
    • /
    • v.33 no.3
    • /
    • pp.767-786
    • /
    • 2018
  • In this paper, we introduce new iterative schemes by using the modified Ishikawa iteration for two hybrid multivalued mappings in a Hilbert space. We then obtain weak convergence theorem under suitable conditions. We use CQ and shrinking projection methods with Ishikawa iteration for obtaining strong convergence theorems. Furthermore, we give examples and numerical results for supporting our main results.

Evaluation of Spatial Uniformity about Resolution and Sensitivity of a 'fixed focusing type SPECT' (고정식 초점형 SPECT에 있어, 선예도와 감도의 공간 균일성에 대한 평가)

  • Kim, Jaeil;Lim, Jeongjin;Cho, Seongwook;Noh, Kyeongwoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.54-58
    • /
    • 2019
  • Purpose At now, there are many kind of dedicated heart SPECT machine in clinical nuclear medicine. Among those, the fixed focusing type SPECT can make a good quality, quantity image because a detectors of this SPECT arranged forward a special ROI and didn't rotate around of body. So, in this paper, we will evaluate a spatial uniformity about resolution and sensitivity at a same plane of a fixed focusing type SPECT. Materials and Methods We used D-SPECT as a fixed focusing type SPECT and Cario MD as a rotated parallel type SPECT to comparing each other. We injected $^{99m}Tc(14.8MBq/1cc)$ to 10 capillary tube (diameter=1mm), and we set those line sources a tfield of view of each SPECT. And then we acquired SPECT date, we applied are construction by recommended methods. By using two tomography images, we calculated a full width of half maximum as a resolution and total counts as a sensitivity, and we compared a CV (coefficientofvariation) values between two images as a spatial uniformity. Results In case of D-SPECT, a CV of resolution and sensitivity are 7.45%, 12.34%. In case of Cario MD, an CV of resolution and sensitivity are 12.49%, 21.84% Conclusion As a results, CV of resolution and sensitivity of a fixed focusing type SPECT is 67.75%, 77.00% higher than ones of a rotated parallel type SPECT. It means that a fixed focusing type SPECT is more uniformed, because this new SPECT can reduce a motion blur artifact by rotating detector around body, also all of detector that made by semiconductor arrange forward a special FOV like heart.

The Effect of Visual Feedback Bicycle Training on Maximal Oxygen Uptake, Quadriceps Muscle Strength, and Running Performance in Healthy Young Adults

  • Kim, Hyeonguk;Lee, Seungwon;Choi, Wonjae
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.1
    • /
    • pp.58-65
    • /
    • 2022
  • Objective: The purpose of this study was to investigate the effect of visual feedback bicycle training on running performance, maximal oxygen uptake and quadriceps muscle strength. Design: A randomized controlled trial. Methods: Fifteen healthy adult men with no musculoskeletal or nervous system disease and capable of bicycle training were included. After the pretest, subjects were randomly assigned to visual feedback bicycle training group and general fixed bicycle training group. Both groups were trained two times a week for three weeks, each week for a fixed time and number of repetitions, followed by a six week washout period and then crossing the training method. visual feedback bicycle training provides visual feedback of heart rate in real time using a monitor and a heart rate meter during bicycle training, and general fixed bicycle training performed general bicycle training without visual feedback. After training, each item was measured using a wearable technology, gas analyzer, isokinetic equipment. Results: The results of this study was significant differences in running performance, maximal oxygen uptake and quadriceps muscle strength in visual feedback bicycle training group (p<0.05). The differential effect was found between visual feedback bicycle training group and general fixed bicycle training group in running performance, maximal oxygen uptake, and quadriceps muscle strength (p<0.05). Conclusions: This study suggested that that visual feedback bicycle training can be applied as a useful training method to improve running performance, maximal oxygen uptake and quadriceps muscle strength.

Effects of Fixed-intensity and Varied-intensity Electroacupuncture in Pain and Sensory Threshold in Patients with Chronic Tension Headache (전침 자극 강도에 따른 만성 긴장성 두통 환자의 통증과 감각역치 변화 연구)

  • Kwon, You-Jung;Lee, Dong-Hua;Lee, Ung-In;Park, Kyung-Mo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.29 no.4
    • /
    • pp.25-34
    • /
    • 2012
  • Objectives : This study was conducted to investigate the effects of fixed-intensity and varied-intensity electroacupuncture in pain and sensory threshold concerning parameters visual analogue scale(VAS), brief pain inventory(BPI) and quantitative sensory testing(QST), among chronic tension headache patients. Methods : Thirty patients with chronic tension headache were randomly assigned to three groups and received different kinds of electroacupuncture at $ST_{36}$ and $ST_{37}$. Group A received fixed-intensity electroacupuncture(fixed-EA), group B received varied-intensity electroacupuncture (varied-EA), and group C received only acupuncture treatment without electrical stimulation as a control group. The intervention was given three times per week, and continued in two weeks. All the experiments were conducted blindly. Results : Fixed-EA group showed a significant decrease of VAS and BPI compared to the baseline measurement, while both varied-EA and control group did not. Of the parameters of QST, subtraction of heat pain threshold(HPT) and cold pain threshold(CPT) slightly increased in all groups, but this was not significant. Conclusions : These results suggest that fixed-EA reduce pain and improve quality of life in patients with chronic tension headache and that acupuncture may regulate patient's pain sensitivity through changing sensory threshold.

Study on the Establishment of Fixed Night Shifts and Flexible Work Arrangements for Nurses (간호사의 야간전담 및 유연근무제도 정착을 위한 실태 조사)

  • Kim, Jeoung Hee;Choi, Eun Ju;Kim, Myoung Sook;Yu, Mi;Jun, Jin Hwa;Kim, Yeon Hee
    • Journal of Korean Clinical Nursing Research
    • /
    • v.25 no.2
    • /
    • pp.107-119
    • /
    • 2019
  • Purpose: The purpose of this study was to investigate the welfare status of nurses and the status of fixed night shifts and flexible work arrangements in both general hospitals and advanced general hospitals in Korea. Methods: A total of 167 hospitals participated in this study, done from April to October 2018. Results: There were 103 hospitals utilizing the fixed night shift system, 22 in the two-shift system, 3 in the fixed holiday shift, 79 in the fixed shift system, and 39 in the short-time working system. The average welfare benefits for nurses increased to 33.02 million won on average. However, welfare services for the nurses were poor: 41.8% of the respondents had a nurses' lounge, 81.7% were given dormitory space at their place of employment, 41.8% had access to welfare facilities, and 56.4% were provided with welfare support countermeasures. Conclusion: The results show an increasing trend of hospitals to utilize fixed night shift and flexible work arrangements. An institutional strategy at the national policy level should be established to implement flexible work arrangements including the fixed night shift system, which has a poor level of welfare.

Optimal Minimum Bias Designs for Model Discrimination

  • Park, Joong-Yang
    • Communications for Statistical Applications and Methods
    • /
    • v.5 no.2
    • /
    • pp.339-351
    • /
    • 1998
  • Designs for discriminating between two linear regression models are studied under $\Lambda$-type optimalities maximizing the measure for the lack of fit for the designs with fixed model inadequacy. The problem of selecting an appropriate $\Lambda$-type optimalities is shown to be closely related to the estimation method. $\Lambda$-type optimalities for the least squares and minimum bias estimation methods are considered. The minimum bias designs are suggested for the designs invariant with respect to the two estimation methods. First order minimum bias designs optimal under $\Lambda$-type optimalities are then derived. Finally for the case where the lack of fit test is significant, an approach to the construction of a second order design accommodating the optimal first order minimum bias design is illustrated.

  • PDF

Spectrophotometric and Kinetic Determination of Some Sulphur Containing Drugs in Bulk and Drug Formulations

  • Walash, M.I.;El-Brashy, A.M.;Metwally, M.S.;Abdelal, A.A.
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.517-524
    • /
    • 2004
  • Two simple and sensitive spectrophotometric methods were developed for the determination of carbocisteine, penicillamine, ethionamide and thioctic acid in bulk and in their pharmaceutical preparations using alkaline potassium permanganate as an oxidizing agent. The first one involves determination of ethionamide and thioctic acid by spectrophotometric investigation of the oxidation reaction of the two drugs. The second method involves determination of carbocisteine and penicillamine by kinetic studies of the oxidation reaction of these two drugs at room temperature for a fixed time of 20 minutes. The absorbance of the colored manganate ions was measured at 610 nm in both methods. 1-10 ${\mu}$g/mL of ethionamide and thioctic acid could be etermined by the spectrophotometric method with detection limits of 0.11 and 0.089 ${\mu}$g/mL for the two drugs respectively. 2-10 ${\mu}$g/mL of carbocisteine and penicillamine could be determined by the kinetic method with detection limits of 0.14 and 0.21 ${\mu}$g/mL respectively. The two methods were successfully applied for the determination of these drugs in their dosage forms.

Theoretical axial wall angulation for rotational resistance form in an experimental-fixed partial denture

  • Bowley, John Francis;Kaye, Elizabeth Krall;Garcia, Raul Isidro
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.278-286
    • /
    • 2017
  • PURPOSE. The aim of this study was to determine the influence of long base lengths of a fixed partial denture (FPD) to rotational resistance with variation of vertical wall angulation. MATERIALS AND METHODS. Trigonometric calculations were done to determine the maximum wall angle needed to resist rotational displacement of an experimental-FPD model in 2-dimensional plane. The maximum wall angle calculation determines the greatest taper that resists rotation. Two different axes of rotation were used to test this model with five vertical abutment heights of 3-, 3.5-, 4-, 4.5-, and 5-mm. The two rotational axes were located on the mesial-side of the anterior abutment and the distal-side of the posterior abutment. Rotation of the FPD around the anterior axis was counter-clockwise, Posterior-Anterior (P-A) and clockwise, Anterior-Posterior (A-P) around the distal axis in the sagittal plane. RESULTS. Low levels of vertical wall taper, ${\leq}10-degrees$, were needed to resist rotational displacement in all wall height categories; 2-to-6-degrees is generally considered ideal, with 7-to-10-degrees as favorable to the long axis of the abutment. Rotation around both axes demonstrated that two axial walls of the FPD resisted rotational displacement in each direction. In addition, uneven abutment height combinations required the lowest wall angulations to achieve resistance in this study. CONCLUSION. The vertical height and angulation of FPD abutments, two rotational axes, and the long base lengths all play a role in FPD resistance form.

A Study on a New Pre-emphasis Method Using the Short-Term Energy Difference of Speech Signal (음성 신호의 다구간 에너지 차를 이용한 새로운 프리엠퍼시스 방법에 관한 연구)

  • Kim, Dong-Jun;Kim, Ju-Lee
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.12
    • /
    • pp.590-596
    • /
    • 2001
  • The pre-emphasis is an essential process for speech signal processing. Widely used two methods are the typical method using a fixed value near unity and te optimal method using the autocorrelation ratio of the signal. This study proposes a new pre-emphasis method using the short-term energy difference of speech signal, which can effectively compensate the glottal source characteristics and lip radiation characteristics. Using the proposed pre-emphasis, speech analysis, such as spectrum estimation, formant detection, is performed and the results are compared with those of the conventional two pre-emphasis methods. The speech analysis with 5 single vowels showed that the proposed method enhanced the spectral shapes and gave nearly constant formant frequencies and could escape the overlapping of adjacent two formants. comparison with FFT spectra had verified the above results and showed the accuracy of the proposed method. The computational complexity of the proposed method reduced to about 50% of the optimal method.

  • PDF

A Study on the Inspection Standards and Methods of Two-Wheeled Motorcycle Headlight (이륜차 전조등 검사기준 및 검사방법에 관한 연구)

  • Ha, Tae-Woong;Hong, Seung-Jun
    • Journal of Auto-vehicle Safety Association
    • /
    • v.12 no.3
    • /
    • pp.7-12
    • /
    • 2020
  • This paper has presented the headlight inspection standards and methods of two-wheeled motorcycles considering Korean Motor Vehicle Safety Standards (KMVSS), Korean Motor Vehicle Inspection Standards (KMVI) and the inspection standards of the International Motor Vehicle Inspection Committee (CITA). As a result of analyzing the headlight luminous intensity test result with fixed inspection equipment, 21% does not meet the inspection standard proposed in this study, and 33.3% in mobile inspection equipment does not meet. The average luminous intensity of motorcycle less than 50 cc is 8,340 cd, so all the lightweight small sized motor cycles do not meet the proposed headlight inspection standard.