• Title/Summary/Keyword: Fireproof

Search Result 128, Processing Time 0.031 seconds

Experimental Study on the Heat Shielding Performance of Lightweight Foamed Concrete Using EPS beads. (EPS 비드를 사용한 경량기포콘크리트의 차열성능의 실험적 연구)

  • Hong, Snag-Hun;Song, Seung-Li;You, Nam-Gyu;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.21-22
    • /
    • 2018
  • Foamed concrete is a porous concrete that is cured by mixing bubbles into cement slurry. It is lighter than ordinary concrete and is characterized by higher insulation. Lightweight foamed concerte is mainly used as a sandwich panel in Korea, and is also used as a refractory filler in fireproof safes. Studies on lightwight foamed concrete have been carried out on strength,density and thermal conductivity. However, it is confirmed that the research on the fire resistance performance is very limited. Based on this study, fire resistance of lightweight foamed concrete using expanded polystyrene beads is investigated.

  • PDF

Tests of Fire and Flame Retardant Performance for Membrane Materials (막재료의 난연 및 방염성능 실험에 대한 연구)

  • Kim, Gee-Cheol;Choi, Kwang-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.16 no.2
    • /
    • pp.55-60
    • /
    • 2016
  • The Membrane structure has a number of problems in the application of a fireproof code based on general buildings codes. Thus, the fireproof code of membrane structure is necessary to activate the construction of the membrane structure. Because it requires a systematic classification of fire retardant and flame proof performance of membrane material. Fire retardant and flame proof tests are conducted on membrane materials mostly used in current construction to propose the fire and flame retardant performance criteria of membrane materials. Fire and flame retardant tests results, PTFE membrane material with the glass fiber fabric have a limit-combustible performance. PVDF membrane material with the polyester fabric does not ensure the fire retardant performance, but this membrane material has the flame retardant performance of a thick fabric. Also, ETFE does not ensure the fire retardant performance, but this membrane material has the flame retardant of a thin fabric.

A study on the characteristic of fire protection covering for high strength concrete (고강도 콘크리트 내화피복 특성연구)

  • Song, Young-Chan;Lee, Sea-Hyun;Kim, Woo-Jae;Yang, Wan-Hee;Park, Dong-Cheol;Baik, Byung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.429-432
    • /
    • 2006
  • In this study a board was made with good fireproof materials of which test was conducted according to the fireproof test for KS F 2257 construction members, and the temperature in coated steel which has a possibility to explode with concrete surface was measured. It is not appropriate to use normal mortar or mortar covering mixed with P.P. fiber to take a measure to prevent the explosive splalling of high-strength concrete. To finalize an Al-Si (aluminosilicates) board-requires over 30mm in thickness at the minimum for the required fire resistance performance and explosion prevention.

  • PDF

Mechanical Performance of Mortar Replacement of Oyster Shell Powder and Egg Shell Powder with Fine Aggregate (굴 패각 분말과 계란 껍데기 분말을 잔골재로 치환한 모르타르의 역학적 성능)

  • Kim, Hae-na;Park, Jun-Seo;Shin, Joung-Hyeon;Hong, Sang-Hun;Jung, Ui-In;Kim, Bong-Joo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.33-34
    • /
    • 2022
  • The purpose of this study was to provide basic data for applying oyster shells and egg shells as fireproof cladding materials by substituting fine aggregates for oyster shell powder and egg shell powder, and comparing strength and fire resistance performance. The reason for the high strength was thought to be that the oyster shell had higher strength than the egg shell itself, and both ESP and OSP were measured at a backside temperature of less than 500℃, so it was judged that it could be used as a fireproof coating for steel structures.

  • PDF

Reforming of Expanded Graphite for Improving Fire Resistance of Fireproof Sealant (방화용 실란트의 내화성 향상을 위한 첨가제로서 팽창흑연의 개질)

  • Hong, In Kwon;Lee, Won Jae;Lim, Hyun Seok;Lee, Seung Bum
    • Applied Chemistry for Engineering
    • /
    • v.28 no.4
    • /
    • pp.437-441
    • /
    • 2017
  • This study was carried out to investigate the volumetric expansion ratio and hardness of expanded graphite after coating with various resins which were used as an additive of fireproof sealant. The coating thickness of the resin, which represents the coating rate, was dependent of the drying speed of the resin and the viscosity of the resin. Therefore the coating thickness was shown as follows: polyvinyl acetate > acrylic resin > urethane resin > water soluble latex. Furthermore, the volumetric expansion ratio was as follows: urethane resin > water soluble latex > acrylic resin > polyinyl acetate and the hardness was as follows: polyvinyl acetate resin > acrylic resin > water soluble latex > urethane resin. This showed that the volume of expansion was reduced by expansion, which was not covered by coating, but significantly increased by increasing hardness and allowed it to be used as a refractory addition. According to the response surface methodology, the optimized addition amount and stirring speed of acrylic resin were 37.6 wt% and 441.4 rpm, respectively.

Study on the High Temperature Properties of Fireproof Mortar Using Various Types of Fine Aggregate (잔골재 종류에 따른 내화피복용 모르타르의 고온 성상에 관한 연구)

  • Lim, Seo-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.100-106
    • /
    • 2014
  • High strength concrete has a structural advantage as well as superior usability and durability, so that its application in building is being steadily augmented. However, in the high temperature like in a fire, the high strength concrete has extreme danger named explosive spalling. It is known that the major cause of explosive spalling is water vapour pressure inside concrete. General solution for preventing concrete from spalling include applying fire protection coats to concrete in order to control the rising temperature of members in case of fire. The purpose of this study is to investigate the high temperature properties of fireproof mortar using organic fiber and various types of fine aggregate for fire protection covering material. The results showed that addition of perlite and polypropylene fiber to mortar modifies its pore structure and reduces its density. This causes the internal temperature to rise. As a results, it is found that a new fireproof mortar can be used in the fire protection covering material in high strength concrete.

A Study on the Combustion Characteristics of Wood According to Flame Resistant Treatment (방염처리 방법에 따른 목재의 연소특성 연구)

  • Park, Sung-Hyun;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.12-18
    • /
    • 2015
  • This study has conducted an experiment of comparing the flame resistant performance and combustion characteristics according to flame resistant treatment using the Cypress Luba and particle board that is commonly used for interior decoration and furniture. As a result of testing the flame resistant performance of Cypress Luba, the Cypress Luba injected with flame resistant resin using the vacuum pressure treatment has shown to have better performances (carbonized area 9.55% and carbonized length 22.91%) than the Cypress Luba treated with flame resistant coating having rubberized plastic components on its surface. For particle board, the specimen attached with fireproof film was identified to be better (carbonized area 40.10% and carbonized length 43.40%) than the specimen with non-fireproof film. For the results of combustion characteristics using the Cone Calorimeter, the specimen treated with flame resistant coating on the surface had faster ignition than the Cypress Luba injected with fire resistant resin using vacuum pressure treatment, and in the total release of calories, the Cypress Luba injected with fire resistant resin using vacuum pressure had $68.2MJ/m^2$, and the specimen treated with fire resistant coating on the surface had $111.52MJ/m^2$. For the particle board, the ignition time had a little difference but in the total release of calories, the specimen attached with fireproof film had $90.1MJ/m^2$ and the specimen with non-fireproof film had $107.6MJ/m^2$.

Assessment of structural fire resistance of a fire-proofed immersed tunnel under tunnel fire scenarios (화재시나리오별 침매터널 구조물의 화재저항성 평가)

  • Choi, Soon-Wook;Chang, Soo-Ho;Kim, Heung-Yon;Jo, Bong-Hyun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.12 no.6
    • /
    • pp.429-441
    • /
    • 2010
  • In this study, fire resistance of a fireproof material sprayed upon an immersed tunnel was experimentally evaluated under $HC_{inc}$ and IS0834(duration of 4 hours) fire scenarios. Under $HC_{inc}$ fire scenario, the maximum inner temperatures of a concrete specimen at the depth of 0, 25 and 50 mm from the interface between the structure and the fire-proofing layer were $311^{\circ}C$, $194^{\circ}C$ and $142^{\circ}C$ respectively. Similarly, the corresponding maximum temperatures under IS0834 fire scenario were $332^{\circ}C$, $222^{\circ}C$ and $179^{\circ}C$ respectively. From the results, it was revealed that the two different fire scenarios assumed in this study have almost the same fire capacity as each other in the maximum temperature concept. In addition, a structural analysis of the immersed tunnel under $HC_{inc}$ fire scenario was carried out to verify the effects of the fireproof material on its structural stability. Material loss and deterioration of a concrete specimen without any fire-proofing measure was also experimentally evaluated to obtain input parameters for the structural analysis under such a severe fire scenario. From the results, it was confirmed that the application of fireproof measures to the immersed tunnel is essential for its structural stability even under a severe fire scenario.