A Model Experiment Study to Secure the Straight Line Distance between the Air Inlet and Exhaust Section of the Living Room (거실제연설비중 공기유입구와 배출구간 직선거리 확보를 위한 모형실험연구)

  • Saeng-Gon Lee;Se-Hong Min
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.2
    • /
    • pp.439-450
    • /
    • 2023
  • Purpose: When conducting fire inspections in Korea, there are objects that violate the fire protection regulations that require a straight line distance of more than 5m between the air inlet and the discharge section if the floor area is less than 400m2, and this paper analyzes the reasons and conducts a model experimental study to support the need for related fire protection regulations. Method: Domestic firefighting objects were investigated and confirmed, domestic and foreign papers, policies, and laws and regulations were examined, and spaces with a straight line distance of less than 5m and more than 5m between the air inlet and discharge section were selected and analyzed through model experiments in a living room of less than 400m2 . Result: When examining the domestic fire protection regulations (NFPCNational Fire Perpormance Code), the separation distance between the air inlet and the outlet is more than 5m when the floor area is less than 400m2 , but as a result of the actual investigation, it was confirmed that there are firefighting objects that cannot keep the separation distance. In addition, when a paper review of overseas fire protection regulations for a straight line distance of more than 5m showed that there was no regulation on the straight line distance between the air inlet and the discharge section, the model experiment showed that the discharge speed was better when the straight line distance between the air inlet and the discharge section was more than 5m than when it was less than 5m. Conclusions: In this study, when examining overseas fire laws and regulations by comparing the performance of the fire protection ratio for the straight line distance between the air inlet and the exhaust section, there is no mandatory regulation for the straight line distance, but the domestic fire protection regulations (NFPCNational Fire Perpormance Code) require more than 5m. It is hoped that this will be reflected in the design stage in the future, and a foundation will be laid to reduce the responsibility and burden of fire superintendents.

A Study on Disaster Management Officer's Perception about the Disaster Response Exercise - Focused on General Officers and Firemen - (재난관리 공무원의 재난대응훈련에 관한 인식 연구 - 일반 행정직공무원과 소방공무원을 중심으로 -)

  • Ko, Gi-Bong;Lee, Si-Young;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.34-44
    • /
    • 2010
  • This research paper surveyed the awareness of general administrative officials who oversee the disaster management and firefighting officials who take part in emergency rescue work in local governments on disaster response exercises. The result of the survey showed that both officials acknowledged the need of the equipment used in disaster response exercises, securing the budgets for exercises, establishing a network among related institutions, reflecting actual conditions and local characteristics to the exercises, reflecting the result of exercise evaluations to the disaster response manual and next exercises, and securing a command communication system required for exercises.

A Study on the Facility Eligibility Inspection of National Inpatient Isolation Units (국가지정 입원치료 격리병상 시설적격성 평가분석에 관한 연구)

  • Hong, Jin Kwan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.10
    • /
    • pp.506-514
    • /
    • 2015
  • During the progression of this study, we visited 17 medical institutions. These medical institutions underwent inspection for facility eligibility of national inpatient isolation units to care for patients. Seventeen consultation meetings were held to gather expert opinions, and conferences were held with the medical institutions and local levels of government. Based on these facts, we established a field application model of the criteria of safety-management and conducted a study on this method in order to create more scientific and systematic safety-management criteria including criteria regarding facilities maintenance and methods of equipment inspection. According to an analysis on the 17 medical institutions examined, facility eligibility of 17 national inpatient isolation units was found to be 78.3% on average. Through analysis of the present domestic and foreign conditions of medical institutions, we proposed improvements for when remodeling becomes necessary and established criteria for safety-management in national inpatient isolation units for the care of patients in accordance with the domestic healthcare system.

A Study on Improvement of Disaster Response System in the Firefighting Organization - Focused on Landslide Case in Sinbuk-eup, Chuncheon-city - (소방의 재난대응체계 개선방안에 관한 연구 - 춘천시 신북읍 산사태 대응사례를 중심으로 -)

  • Ko, Gi-Bong;Lee, Si-Young;Chae, Jin
    • Fire Science and Engineering
    • /
    • v.26 no.2
    • /
    • pp.17-31
    • /
    • 2012
  • Regarding the landslide that took place around 00:08 on July 27, 2011, in a village in the city of Chuncheon (Sanjidanggol, Majeoksan, Cheonjeon-ri, Sinbuk-eup, Chuncheon-city, Gangwon-province), this paper surveyed fire-fighting officers who were injected into the site to rescue the disaster, thereby determining the problems surrounding the initial fire-fighting response and improvement measures. As a result, specialist education of volunteer fire-fighters and utilization, improvement measures included the early response ability enhancement of and cooperation between relevant agencies, the strengthening of specialist education about landslide response, the strengthening of situation management and field command system, the installation and operation of speedy field emergency infirmary, the operation of an appropriate volunteer waiting facility, the operation of an appropriate control lines, appropriate control of media, a sufficient securing of individuals' rescue equipment and fuel for heavy equipment, the provision of sufficient portable radios and chargers, the securing of fire-fighting budget thereof.

Convergent Influence Effect on the High - Quality CPR of 119 Paramedics by Wearing Personal Protective Equipment by Level (구급대원의 수준별 개인용 보호구 착용에 따른 심폐소생술 품질에 미치는 융합적인 영향)

  • Shin, Dong-Min;Cho, Byung-Jun;Yang, Hyun-Mo;Jeon, Seong-Man;Han, Yong-Taek
    • Journal of the Korea Convergence Society
    • /
    • v.11 no.4
    • /
    • pp.71-78
    • /
    • 2020
  • The purpose of this study is to investigate the effect of wearing clothes, Level B, and Level C PPE on normal CPR using mannequins. The paramedics who participated in this experiment were 20 paramedics with more than 5 years of experience in firefighting area C. It was found that chest compressions in the process that hand off time was 11.9 seconds in the uniform wearing group, 11.4 seconds in the level C PPE wearing group, and 13.1 seconds in the SCBA wearing group. In other words, wearing personal protective equipment prevents the movement of paramedics and uses compensatory movements, which may increase the difficulty of efficient first aid. If this situation persists, it may cause fatigue and damage to the body of paramedics. Rescue and paramedics should wear level personal protective equipment in case of emergencies and conduct rescue and CPR training.

Fire Modeling and Smoking Control Characteristic Analysis of Electric Room by Using FDS (FDS를 이용한 전기실의 화재모델링 및 연기제어 특성 분석)

  • Choi, Jeong-A;Lee, Min-Gu;Lee, Dae-Dong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.3
    • /
    • pp.662-668
    • /
    • 2018
  • Most electric rooms are located in the underground spaces of buildings. When a fire occurs in electrical equipment, the fire expands to cable insulation material, resulting in toxic smoke and combustion products. If the smoke and combustion products quickly move vertically and horizontally, the evacuation of occupants and firefighting activities will be hindered. Therefore, it is necessary to design optimal equipment for smoke control in cases of fires in electric rooms. This study analyzes the characteristics of smoke and combustion products in fires in a cubicle-type switchboard in an electric room using PyroSim, which is based on the program Fire Dynamics Simulator (FDS). The fire modeling consists of four scenarios according to the operation mode of the mechanical ventilation equipment, the amount of air supply and exhaust, and the location of the air supply slot. The analysis shows that the mechanical ventilation equipment improves the smoke density, visibility, carbon monoxide concentration, and temperature characteristics. The visibility and temperature characteristics were improved when the air flow rate and the location of the air supply slot from fire defense regulations were applied.

Classification of Fire Causes in Warehouses Using the TRIZ Technique and Analysis of Preventive Measures Accordingto 4M (TRIZ기법에 의한 물류창고의 화재원인 및 4M에 따른 예방대책 분석)

  • Han, Sang-Hun;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.3
    • /
    • pp.401-412
    • /
    • 2020
  • This study analyzed the causes of warehouse fires using a creative problem-solving technique called TRIZ. It identified preventive measures by applying 4M. The results are as follows. First, this study examined the inconsistency among the causes of warehouse fires using TRIZ. Second, it analyzed human factors and fire prevention measures in warehouses such as safety standards for managers, and methods for the promotion of safety consciousness among workers, and for the reinforcement of construction technology for sandwich panel workers. Third, it identified the mechanical and facility factors and fire prevention measures in warehouses such as safety facilities, the expanded installation of safety devices, the adoption and development of fire suppression equipment, and the deployment of methods to improve the fire resistance of sandwich panels. Fourth, it presented working and environmental factors and fire prevention measures in warehouses such as the tightening of safety precautions and the supervision of working methods, and setting fire partitions both in loading places and based on performance-based design. Finally, it proposed managerial factors and fire prevention measures in warehouses such as specific targeting for firefighting with low fire hazards, reviewing the material quality regulations of non-combustible or higher for sandwich panels in the specific target of firefighting that cannot apply fire safety standards, installing sprinklers in cold storage, and mandating the installation of automated facilities with retroactive application regardless of the floor area in the warehouse with a sandwich panel structure.

Risk Perception of the Firefighters Responsible for Nuclear Power Plants: Construct Validity (원자력발전소 화재에 대한 관할 지역 소방관의 위험인식: 측정도구의 개발과 타당화)

  • Choi, HaeYoun;Lee, SangKyu;Choi, Jong-An
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.94-102
    • /
    • 2019
  • As the importance of first responses for fire accidents has grown in the safety management of nuclear power plants, a systematic approach to measure firefighters' psychological states and competence is needed. The current study investigated the construct of the risk perception of the firefighters working near nuclear power plant sites, and then developed and validated a new scale to measure firefighters' risk perception regarding nuclear power plant accidents. The scale items were developed on the basis of literature review and interviews with the firefighters working near nuclear power plant sites. In order to validate the new scale, we recruited 180 firefighters from five fire stations in the vicinity of the nuclear power plants in Jeonnam Province, Gyeongbuk Province, and Busan. The results of exploratory factor analyses revealed that the scale consisted of five factors: "manual" reflecting a lack of response guidelines and manuals for fire incidents and radioactive material release; "fear" reflecting a fear of fire incidents in the nuclear power plants and their catastrophic consequences; "resource" reflecting a lack of protective equipment and manpower for responding to fire incidents in the nuclear power plants; "trust" reflecting trust and cooperation with the counterpart institutions for firefighting in the nuclear power plants; and "knowledge" reflecting the knowledge of radioactivity and firefighting in the nuclear power plants. Further analyses provided statistical evidence supporting for the 15-item scale's internal consistency and construct validity. Finally, We discussed the implication and limitations of the current research.

A Study on Korean University Students Perception of Fire Officers (소방공무원에 대한 대학생의 인식에 관한 연구)

  • Lee, Chul Hee;Ankhbayar, Lkhaasuren;Lee, Jae Wook
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.2
    • /
    • pp.217-226
    • /
    • 2022
  • The purpose of this study is to quantitatively examine the perception of fire officials for college students who need to prepare and choose fire officials, and to identify and present practical and specific improvement measures along with raising awareness of fire officials. In order to achieve the basic purpose of the study set above, we tried to find out whether there are differences in the general level of awareness of fire officials, the working environment of fire officials, and group welfare according to the gender, major, grade, family or relative of college students. The subjects of the study were 600 students enrolled in a four-year university in the Department of Firefighting, and 513 valid questionnaires were used. The survey contents were divided into three categories of perceptions of firefighting officials and consisted of 20 questions, and the frequency and percentage were calculated and compared using the SPSS/win (Ver10.0) program. As a result, first, compensation for awareness improvement and the expansion of safety facilities and equipment are necessary. Second, it is necessary to improve working conditions, such as guaranteeing appropriate working hours and raising and replenishing wages. Third, the results of the establishment of a national fire hospital and the need for psychological counseling were derived. Based on these results, we suggest that national-level laws and systems, and administrative and legislative support should be provided for firefighters.

A Review on the Improvement of the Meaning and Composition Requirements of Interference with Fire Protection Activities - Focusing on Interference with 119 EMS Activities - (소방활동방해죄의 의미와 구성요건 개선에 관한 검토 -119구급활동 방해를 중심으로-)

  • Young Pyo Hong
    • The Korean Society of Law and Medicine
    • /
    • v.24 no.3
    • /
    • pp.105-124
    • /
    • 2023
  • Modern society is facing an unstable environment due to unexpected accidents and hazardous situations. For example, incidents such as the collapse of the Bundang Bridge and the crushing accident in Itaewon could serve as examples. In addition to these, critical emergencies like sudden cardiac arrests and strokes frequently occur, requiring swift actions and smooth transfers to specialized medical institutions for effective responses. In response to these risks, the country has been establishing various systems to protect the lives and safety of its citizens. Among these, the 119 First Aid Activities plays a crucial role within the emergency medical system. Its goal is to promptly respond to critical emergency situations involving severe trauma patients or patients with serious illnesses, minimizing damage and safeguarding lives by swiftly transferring them to emergency medical institutions for specialized treatment. The core activity related to this is emergency rescue operations. In particular, the 119 First Aid system serves as a crucial institution responsible for the hospital transportation of emergency patients. However, rescue personnel still encounter cases of interference with their activities during their duties. Despite efforts from the police, these interference cases persist, and they share similarities with the crime of obstructing official duties. Interference with emergency activities exhibits a comparable nature to instances such as physical assaults and equipment damage against emergency medical practitioners working within the emergency medical system. Therefore, a comprehensive understanding and improvement efforts regarding the issues of interference that arise during the process of emergency medical activities, including the 119 First Aid system, are necessary. The solution to these problems is to establish and improve the conditions for obstruction of first aid activities, focusing on the "Framework Act on Firefighting" and the "Act on 119 Rescue and Emergency."