• Title/Summary/Keyword: Fire system

Search Result 3,399, Processing Time 0.025 seconds

Fire Safety Labeling System for Household Goods to Prevent House Fires

  • Kyong-Jin Park;Bong-Kil Kim;Hyun-Mi Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.4_1
    • /
    • pp.735-740
    • /
    • 2024
  • Data released by the National Fire Agency showed that the total incidence of fires from 2014 to 2023 was 410,497, among which 75,215 were house fires, constituting 18% of the total occurrences. The fatalities resulting from house fires numbered 1,435. Fatalities stemming from prior house fires occurred between midnight and 6 am, coinciding with periods of sleep and diminished responsiveness to fire emergencies. A fire safety labeling system is proposed to prevent fire hazards associated with household products. This system primarily entails indicators of thermal energy and inherent fire attributed to household products. Furthermore, the Korea Fire Safety Institute has suggested adopting a risk label as a concrete measure plan for implementing the fire safety labeling system for household products. The results promise to safeguard the public against fires and increase the exports of household commodities by enhancing the corporate reputation through positive association with fire safety measures.

A Study on the Fire Safety of High-rise Apartments Based on Fire Door Switch and Automatic Fire Extinguishing System

  • Zhang, ZeChen;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.424-430
    • /
    • 2021
  • The purpose of this study is to analyse the characteristics and spreading laws of parameters such as fire smoke, concentration of CO, visibility, and temperature at fire scene in high-rise residential buildings under the different conditions of fire doors and automatic fire extinguishing systems. Using Pyrosim to simulate diverse fire scenes in a high-rise apartment with corridors, to analyze the changes in those parameters. The results show that when a fire occurs, closing the fire-fighting corridor will increase the smoke temperature and concentration of CO in the stairwell, and reduce the height and visibility of the smoke layer; the automatic fire extinguishing system effectively suppresses the increase in the temperature of the fire smoke and the sedimentation of the smoke layer. Reasonable setting and operation of the automatic fire extinguishing system could effectively inhibit the spread of fire. Although closing fire corridor can slow down the direct upward spread of smoke through the corridor, it will force the fire smoke into the stairwell, which will seriously affect evacuation through the stairs. Therefore, in order to reduce risks, it is forbidden to close the fire doors of the firefighting corridor and stacking combustible materials in the corridor, Also, intensifying inspections and ensuring the normal operation of the automatic fire extinguishing system are indispensable. Based on the research results, the significance of installing fire-fighting facilities in the construction of high-rise apartments was discussed and proved.

A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities (효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구)

  • Son, Gae-Seong;Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

Research about Improvement Way of Fire Investigation System - Regarding Product Liability Responsibility Law - (화재조사 제도의 개선방안에 관한 연구 - 제조물 책임법과 관련하여 -)

  • Mun, Yong-Soo;Kong, Ha-Sung;Yoon, Myong-O
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.105-111
    • /
    • 2008
  • Improvement of fire investigation system is required to supplement problem that can happen after product liability law enforcement of our country. This treatise searches special quality of inside and outside of the country fire investigation that was enforced present with theoretical background of manufacture water responsibility law and compared. And is based and grasped objective and hangup in police fire investigation, fire fighting fire investigation, engine fire investigation of private fire judgment. By improvement way accordingly first, proposed fire emotion connection studies and establishment and connoisseurship qualification system establishment etc. in the common people private fire diet, judgment, analysis company's necessity second, fire fighting of fire investigation system, police's member anger third, college.

An Analysis on the Effect of Pressure System Installation on the Pipeline to Identify Pressurized Water and Self-inspection Ease in Apartment Building (아파트에 설치하는 옥내소화전 압력계 설치가 배관의 가압수 식별 및 자체점검 용이성 간의 영향 분석)

  • Son, Joo-Dal;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.22 no.1
    • /
    • pp.33-44
    • /
    • 2020
  • This study analyzed how the installation of a pressure gauge in the indoor fire hydrant of an apartment building affected identifying pressurized water in the pipe, making it easier to conduct internal inspection on the fire suppression system, and ensuring reliability of fire suppression. The following are the study's results: First, identifying pressurized water in the indoor firefighting pipe had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that a higher level of identification of pressurized water in the indoor firefighting pipe had a positive impact on improving the installation and use of a pressure gauge in the indoor fire hydrant. Second, making it easier for the fire safety officer to inspect the fire suppression system had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This suggests that if it becomes easier for the apartment building's stakeholder to conduct internal inspection or the firefighting facility manager to carry out inspection on the fire suppression system, it would have a positive effect on the installation of a pressure gauge in the indoor fire hydrant. Finally, ensuring reliability in fire suppression had a positive effect on the installation of a pressure gauge in the indoor fire hydrant. This implies that if it becomes easier to identify pressurized water in the indoor firefighting pipe, for the fire safety officer to conduct internal inspection, or for the firefighting facility manager to carry out inspection in accordance with the fire suppression system's internal inspection requirements, it would increase reliability in fire suppression, making it more necessary to install a pressure gauge in the indoor fire hydrant.

A Study on Methods for Capacity Building of Fire Cause Investigation in Fire Stations (소방기관의 화재원인조사 역량 강화 방안에 관한 연구)

  • Lee, Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.25 no.5
    • /
    • pp.108-118
    • /
    • 2011
  • In this study, strengths related with fire investigation of fire stations are analyzed and methods for the capacity building of their fire cause investigation are suggested. The methods for capacity building of fire cause investigation suggested are focused on using potential and strengths of current fire fighting and enhancing internal capacity rather than reinforcing investigation personnel, organization, and equipment and ensuring investigation power. The methods suggested in this study are as follows. 1) Because fire investigation results are the basis of fire administration, fire marshals should change their awareness of the need of fire investigation; 2) A fire investigation system should be established to ensure statements of people concerned systematically; 3) A substantial system of fire cause investigation should be established to investigate fire scenes more than twice; 4) A substantial system of fire cause investigation should be established to use such materials as CCTV; 5) Extinguishing should be made in consideration of fire cause investigation and a scene preservation system after extinguishing should be established; 6) A fire investigation system should be established in connection with 119 first-aid and rescue teams and 7) Steps to raise the morale of fire investigation staff should be taken.

Application of Signal Pattern Recognition Technique of Digital Wireless Fire Alarm System (디지털 방식 무선 화재알림설비의 신호 패턴 인식기법 적용)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.5
    • /
    • pp.14-21
    • /
    • 2022
  • The purpose of this study was to apply the signal pattern recognition technique to the digital wireless fire-alarm system and to reduce unwanted fire alarms. In this study, the fire alarms of the K Institute, which operates the largest digital wireless fire-alarm system in Korea, were classified into normal operations and unwanted fire alarms, and these were analyzed and compared with actual fire signals. In addition, by designing a non-fire signal filter and applying it to the K Institute, we confirmed that the monthly unwanted fire alarm rate of all 5,713 detectors decreased sharply. In particular, the unwanted fire alarm rate for flame decreased from 1.09% to 0.11% and the unwanted fire alarm rate for smoke decreased from 0.65% to 0.035%.

Design of Integrated Smart Fire Protection System for Rack Storage (랙크식 창고 통합 스마트 화재대응 시스템 설계)

  • Kim, Jong-Hoon
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.26-36
    • /
    • 2020
  • It is very difficult to suppress fire by rapid flame spread through flue space between flammable commodities on the rack when a fire occurs in the rack storage. At present, the fire protection system for rack storage in Korea has many issues, and the new fire protection system was designed and developed by it. A smart system using the sensor network and artificial intelligence was designed to detect fire very rapidly and track the location of a fire. In the very early stages, the system was constructed using vertical open sprinkler pipes, wet pipes, and solenoid valves to allow water to spray near fire locations. Based on the design results, the system was installed and tested, and the full-scale test was successfully completed.

A Study on Plan for Introduction of Fire Influence Evaluation System through Risk Assessment of the Urban Lifestyle Housing Buildings (도시형 생활주택의 위험성 분석을 통한 화재영향성평가제도의 도입방안에 관한 연구)

  • Kim, Dong-Wook;Baek, Sona;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.31 no.1
    • /
    • pp.10-17
    • /
    • 2017
  • Securing fire safety using only fire-fighting facilities is difficult because causes of modern fire vary, such as architectural structures and building use patterns. In order for fire safety to be guaranteed by enacting and revising fire regulations reflecting the fire hazard characteristics and user's characteristics, the introduction of fire influence evaluation (fire risk assessment) system needs to be considered in a timely manner to be adopted but unfortunately two attempts before have failed. In this study, a fire case of urban lifestyle housing was surveyed to introduce a fire influence evaluation system and a field survey on the actual condition of the 414 urban lifestyle housing buildings and fire & evacuation simulation results of one representative building in Suyoung-gu and Nam-gu District of Busan Metropolitan City were analyzed. The necessity, procedures and implementation method of fire influence evaluation system were questioned and tested by the professional fire experts, fire officers and firefighters and architects. On the basis of these facts, introduction of (fire influence evaluation system) should be absolutely adopted and the fire department and fire regulation are eligible to implement the system. Therefore, fire regulation needs to be enacted or revised in accordance with the new fire environment and fire safety system that needs to be built up. Accordingly, aggressive promotion through public hearings on the necessity of fire impact assessments, consensus among departments and fostering experts to carry out fire influence evaluation system will be the core.

The Application of Expert System in Fire Code Analysis (소방법규해석에 대한 EXPERT SYSTEM의 적용)

  • 김회천;손재열;김화중;박병윤
    • Fire Science and Engineering
    • /
    • v.3 no.3
    • /
    • pp.9-13
    • /
    • 1989
  • This paper realizers expert system which is searched most suitable system of the fire facilities by regulating of fire operating order And so, the user finds the inference, heuristic knowledge of the expert who has a mastery of application of the fire code objected protection, warning or extinguishing of fire. Although some expert systems utilize artificial intelligence such as LISP or PROLOG, this study utilizes M.1 that is available expert system development tool running with personal computer.

  • PDF