• Title/Summary/Keyword: Fire safety law

Search Result 159, Processing Time 0.025 seconds

Problem and Improvement Plan of Existing Fire Examination and Investigation System (현행 화재조사 및 수사체계의 문제점과 개선방안)

  • Kim, Hyung-Doo
    • Fire Science and Engineering
    • /
    • v.21 no.1 s.65
    • /
    • pp.37-50
    • /
    • 2007
  • A primary task of fire department is maintaining public safety, system maintenance and welfare improvement by protecting life, body and property of a people through prevent and extinguish of the fire in emergency. Rescue part of those affairs has supported by the people but affairs related to the fire examination and investigation could not get it. Although fire examination is a very important part of fire department administration, it has been understood indifferently due to lack of awareness and concern. There are no scientific fire examination because of lacking education study and the whole responsibility capacity about it. There are many things have to be improved at fire examination and investigation system in Korea. Especially, establishment of the whole responsibility post is urgent through assuring professionals to improve accuracy of fire examination and investigation. Equipment which can do scientific fire examination and investigation have to be fully furnished. Efficiency of fire examination and investigation has to be increased through improving law related to fire examination and investigation, giving rescuers investigation right. Through this, it systematically have to be good for fire prevent.

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Conceptual Study of a Framework for Real-Time Railway Safety Monitoring and Control System Based on Safety Performance Monitoring Indicators (안전성과 모니터링지표 기반의 실시간 철도안전 감시제어 시스템의 프레임워크에 대한 개념 연구)

  • Lee, Donghoun;Tak, Sehyun;Kim, Sangahm;Yeo, Hwasoo
    • Journal of the Korean Society for Railway
    • /
    • v.19 no.4
    • /
    • pp.526-538
    • /
    • 2016
  • The government of South Korea has made great efforts in the area of railway safety management by means of a railway safety law and an integrated railway safety plan established in 2004 after the Daegu subway fire accident. However, after certain railway incidents, a reactive railway safety management system has been implemented that has led to fatal accidents caused by the collision, derailment, and fire every year. Hence, this study is intended to propose a framework that integrates data from distributed detection devices into a real-time railway safety monitoring and control system for proactive safety management. Furthermore, we will provide a future development direction for safety performance monitoring indicators to determine whether the railway safety monitoring and control system works effectively. The proposed framework is expected to be a cornerstone for the real-time railway safety monitoring and control system to be implemented in the future.

A Study on Improving the Efficiency of the Survival Rate for the Offshore Accommodation Barge Resident Using Fire Dynamic Simulation (화재시뮬레이션을 이용한 해양플랜트 전용생활부선 거주자의 생존율 향상에 대한 연구)

  • Kim, Won-Ouk;Lee, Chang-Hee
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.6
    • /
    • pp.689-695
    • /
    • 2015
  • The offshore plant crews that were commissioned in the commercial startup phase boarded the offshore plant in two shifts until the end of the project. The crews who were hired by the owner side stayed in the original offshore plant during the project. However, most of the offshore plant commissioned members who were dispatched from the shipyard were accommodated in the offshore accommodation barge. For this reason, they were exposed to many accidents since there are a lot of people staying in a small space. This study suggested a method for improving survival rate at offshore accommodation barge in terms of life safety. It is assumed that the fire accident among unfortunate events which take place in the offshore accommodation barge mainly occurred. So, this study analyzed the safety evacuation for offshore plant employees using fire simulation model based on both domestic and international law criteria. In particular, When fire occurs in the offshore accommodation barge, the periodically well trained crews are followed safety evacuation procedure. whereas many employees who have different background such as various occupations, cultural differences, races and nationality can be commissioned with improper evacuation behaviors. As a result, the risk will be greater than normal situation due to these inappropriate behaviors. Therefore, This study analyzed the Required Safe Escape Time (RSET) and Available Safe Escape Time (ASET). Also it was suggested the improvement of structure design and additional arrangement of safety equipment to improve the survival rate of the residents in offshore accommodation barge.

A Numerical Study on the Smoke Behavior by Solar Radiation through Ceiling Glass in Atrium Fires

  • Jeong, Jin-Yong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.10 no.3
    • /
    • pp.117-128
    • /
    • 2002
  • This paper describes the smoke filling process of a fire field model based on a self-deve-loped SMEP (Smoke Movement Estimating Program) code to the simulation of fire induced flows in the two types of atrium space containing a ceiling heat flux. The SMEP using PISO algorithm solves conservation equations for mass, momentum, energy and species, together with those for the modified k-$\varepsilon$ turbulence model with buoyancy production term. Also it solves the radiation equation using the discrete ordinates method. Compressibility is assumed and the perfect gas law is used. Comparison of the calculated upper-layer average tempera-ture and smoke layer clear height with the zone models has shown reasonable agreement. The zone models used are the CFAST and the NBTC one-room. For atrium fires with ceiling glass the ceiling heat flux by solar heat causes a high smoke temperature near the ceiling. However, it has no effect on the smoke movement such as the smoke layer clear heights that are important in fire safety. In conclusion, the smoke layer clear heights that are important in evacuation activity except the early of a fire were not as sensitive as the smoke layer tem-perature to the nature of ceiling heat flux condition. Thus, a fire sensor in atrium with ceiling glass has to consider these phenomena.

A Study on Setting the Grade of Vertical Evacuation Rank to Introduce an USN-based Evacuation System into Super High-rise Apartment Housing's (초고층 공동주택의 USN기반 피난시스템 도입을 위한 수직적 피난위계 설정에 관한 연구)

  • Hong, Won-Hwa;Jeon, Gyu-Yeob;Choi, Jun-Ho
    • Journal of the Korean housing association
    • /
    • v.18 no.5
    • /
    • pp.133-141
    • /
    • 2007
  • The purpose of this study is to secure an evacuation time and to ensure safety by using an Ubiquitous Sensor Network computing when a fire breaks out at a super high-rise apartment housing. A super high-rise apartment housing that is a type of building to solve the problem of separation of the urban function and the phenomenon of hollowing out downtown has been on the increase, high-rise apartment housings occupying 52.7% of whole housings in 2005. However, if a fire breaks out, there would be serious damage since it accommodates many people and facilities as existence of vertical gigantism in the city. The architectural law in force has no clause on it which is universally applicable to general building, it is difficult to be applicable to a densely super high-rise apartment housing and there would be in danger of a resident's evacuation in the fire. Therefore, as a previous study to introduce an USN-based fire-warning facility and evacuation equipment, this study shows the improvement way after analyzing factors that are barriers to evacuaee's behavior of a super high-rise apartment housing and also shows establishment of the grade of vertical evacuation rank by SimuleX, one of the best computer simulation program.

Measurement of Flash Points for n-hexanol+n-butyric acid and n-butanol+propionic acid by Seta-flash Closed Cup Method (Seta-flash 밀폐식 방법에 의한 n-hexanol+n-butyric acid 계와 n-butanol+propionic acid 계의 인화점 측정)

  • Ha, Dong-Myeong;Lee, Sungjin
    • Journal of the Korean Society of Safety
    • /
    • v.29 no.6
    • /
    • pp.76-80
    • /
    • 2014
  • The flash point is one of the most important physical properties used to determine the fire hazard of flammable liquid mixture and defined as the lowest temperature at which a liquid produces sufficient vapor to form a combustible mixture with air. The main purpose of this paper is to measure and predict the flash point of binary flammable miscible mixtures. The flash points for n-hexanol+n-butyric acid and n-butanol+propionic acid, were measured by using Seta-flash closed cup method. The experimentally derived data were correlated with the binary interaction parameters of the van Laar and NRTL equations through the optimization method. The flash points estimated by these correlations were compared with those calculated by the method based on Raoult's law. The optimization method were found to be better than the method based on the Raoult's law.

Globalization Development Plans of the Convergence Systems and Policies for Domestic Fire Industry (국내 소방산업의 글로벌화 융합형 제도와 정책의 발전방안)

  • Ku, Jae-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.6 no.5
    • /
    • pp.55-61
    • /
    • 2015
  • This study is related with globalization development plans of the convergence systems and policies for domestic fire industry. The current issues are analysed from the condition of the policy enforcement of fire industry promotion and analysis results of the fire industry's environment. Consequently, advanced plans of promotion law and overseas expansion plans for fire industry is proposed, Especially, overseas expansion plans include technology policy strategies and activate plans of overseas expansion support for fire industry. Plans of overseas expansion support for fire industry are discussed in terms of three detailed plans including with diversification of foreign exhibitions support of fire industry, dispatch expansion of overseas market pioneer and expansion of the asian emerging markets. Especially, plans of expansion of the asian emerging markets will lead the strategic performances including with establishment of superiority in domestic fire system, provision of infrastructure abroad in domestic fire industry and of Induction of establishment in domestic fire inspection systems.

A Study on the Improvement of the Basic Safety Training Course and Regulation for Fishing Vessel Seafarers (어선원 기초안전교육 교육과정 및 제도 개선에 관한 연구)

  • CHO, Jang-Won;HAN, Se-Hyun;KIM, Ki-Sun
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.29 no.3
    • /
    • pp.857-868
    • /
    • 2017
  • The basic safety training for fisheries is being conducted to cope with an emergency situation and prevent the maritime accidents. A new joined person must be educated the safety training and a refresher must be completed the refresher training course every 5 year in according to the STCW-F and seafarers' Act. In order to achieve the objectives of marine safety training, it is necessary to distinguish the trainees by ship's type and the courses should be implemented in consideration of safety equipment of fishing vessels. However, since the classification criteria of seafarers' Act are unclear, the officer of fishing vessels which is over G/T 25 tons has been trained through the same course and curriculum for merchant ship's seafarers. About 80 % of domestically registered fishing vessels are small size ships(less than 100 tons) and there is not many safety equipment required by law. In case of marine accidents such as collision, the small vessel losses its buoyancy and stability caused by damage of hull. despite fisheries fall into the sea during fishing work in bad weather on the deck, there was no safety equipment by law. So fisheries must be trained by a safety training course suitable for fishing vessel. The purpose of this study is to develope the suitable course for fisheries by analysis current curriculum and rules. so suggested the basic safety training course for fisheries and institutional improvement.

A Study on Proposals for Improving the Fire Protection Regulations for Nuclear Power Plants (원자력발전소 화재방호 규제 개선 방향에 관한 연구)

  • Ma, Jin-Soo;Kwon, Kyung-Ok
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.116-122
    • /
    • 2010
  • The fire protection system of nuclear power plants shall be designed, constructed and operated, through a defense-in depth criterion to suppress the leakage of radioactivity to the outside and to allow the safety shutdown function when a fire occurs. In order to achieve these purposes, most of countries abroad operating the nuclear power plants keep up the integrated regulations, however we have two guidelines, the fire protection service act and the nuclear energy act, as mandatory requirements to apply to the fire protection systems in nuclear power plants. It has shown that USA, Canada and Japan which have long experience in operating nuclear power plants have regulations integrated technically for fire protection system of nuclear power plants. It is proposed that the things once verified the risk analysis of the fire hazard by the nuclear law in the design for fire suppression system in plants should be authorized by the fire protection service act as an exception.