A study on the assessment of wildland fire hazard through statistic examination and calorie analysis according to the geographical distribution of vegetation (통계적 고찰과 수목분포에 따른 열량분석을 통한 산림화재 위험성 평가에 관한 연구)

  • 김광일;김동현
    • Fire Science and Engineering
    • /
    • v.14 no.3
    • /
    • pp.27-32
    • /
    • 2000
  • The assessment of wildland fire hazard is the first priority to be considered in the prevention, extinction and control of wildland fire. For the standard to measure wildland fire hazard, the wildland fire Warning System is currently being used in Korea which computes the wildland fire occurrence hazard index through a stick weight to moisture conversion formula. It shows the risk of fuel substance being exposed to fire by meteorological factors. For a comprehensive assessment of wildland fire hazards by area, the major factors'hazards need to be measured and the assessment of wildland fire needs to be conducted through historical statistic examination. Therefore, the wildland (ire outbreak frequency and its seriousness of damage are analyzed through historical statistic examination to conduct the assessment of a wildland fire hazard, and then the calorific value of a forest is analyzed through differential scanning calorimeter measurement which assesses the comparative calorific hazard according to the geographical distribution of vegetation.

  • PDF

Application of Fire Risk and Fire Risk Rating Assessment for Four Species of Wood According to Chung's Equation-XII (Chung's Equation-XII에 의한 목재 4종의 화재위험성 및 화재위험성 등급 평가 적용)

  • Yeong-Jin Chung;Eui Jin
    • Applied Chemistry for Engineering
    • /
    • v.35 no.1
    • /
    • pp.29-36
    • /
    • 2024
  • The fire risk and fire safety of four types of wood were comprehensively evaluated according to Chung's equation-XII. White ash, willow, fraxinus mandshurica, and sagent cherry trees were selected as test specimens. A cone calorimetery (ISO 5660-1) was used to examine the combustion characteristics of the test piece, and finally, the fire risk rating (FRR) was predicted using the fire risk index-XII (FRI-XII). The predicted fire performance index-X (FPI-X) and fire growth index-X (FGI-X) ranged from 469.03 to 1109.73 s2/kW and 0.0009 to 0.0280 kW/s2, respectively. Additionally, the fire performance index-XI (FPI-XI) and fire growth index-XI (FGI-XI) ranged from 0.41 to 0.97 and 1.11 to 3.11, respectively. The fire risk index-XII (FRI-XII), representing a fire risk rating, showed that the fire risk of frasxinus mandsurica tree (FM) was very high at 7.60 (fire risk rating: D). And it was compared with Chung's equation-IX, fire risk index-IX (FRI-IX). The fire risk ratings according to FRI-IX and FRI-XII were generally high for willow and frasxinus mandsurica trees. Additionally, the results of FRI-XII and FRI-IX had a similar relationship, and the size of each fire safety rating closely matched each other.

A Study on Fire and Explosion Index in the Petro-chemical Plant (위험성 평가중 화재.폭발 지수 산정방법에 관한 고찰)

  • 김진곤;김광일
    • Fire Science and Engineering
    • /
    • v.7 no.1
    • /
    • pp.17-29
    • /
    • 1993
  • The method has been proposed for the risk assessment of petro-chemical plant, specially which can evaluate relative risk levels on the materials and process-es. The each potential risk of materials and processes are derived numerically and combined these values, finally Fire and Explosion Index was found. Material factor was evaluated with the flammability and the reactivity and process factor with emprical factor called penalty. This F&EI can be performed for relative risk assesment at the whole plant and directely applicable at the line.

  • PDF

A study on fire design accidental loads for aluminum safety helidecks

  • Kim, Sang Jin;Lee, Jin;Paik, Jeom Kee;Seo, Jung Kwan;Shin, Won Heaop;Park, Joo Shin
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.8 no.6
    • /
    • pp.519-529
    • /
    • 2016
  • The helideck structure must satisfy the safety requirements associated with various environmental and accidental loads. Especially, there have been a number of fire accidents offshore due to helicopter collision (take-off and/or landing) in recent decades. To prevent further accidents, a substantial amount of effort has been directed toward the management of fire in the safety design of offshore helidecks. The aims of this study are to introduce and apply a procedure for quantitative risk assessment and management of fires by defining the fire loads with an applied example. The frequency of helicopter accidents are considered, and design accidental levels are applied. The proposed procedures for determining design fire loads can be efficiently applied in offshore helideck development projects.

PRA RESEARCH AND THE DEVELOPMENT OF RISK-INFORMED REGULATION AT THE U.S. NUCLEAR REGULATORY COMMISSION

  • Siu, Nathan;Collins, Dorothy
    • Nuclear Engineering and Technology
    • /
    • v.40 no.5
    • /
    • pp.349-364
    • /
    • 2008
  • Over the years, probabilistic risk assessment (PRA) research activities conducted at the U.S. Nuclear Regulatory Commission (NRC) have played an essential role in support of the agency's move towards risk-informed regulation. These research activities have provided the technical basis for NRC's regulatory activities in key areas; provided PRA methods, tools, and data enabling the agency to meet future challenges; supported the implementation of NRC's 1995 PRA Policy Statement by assessing key sources of risk; and supported the development of necessary technical and human resources supporting NRC's risk-informed activities. PRA research aimed at improving the NRC's understanding of risk can positively affect the agency's regulatory activities, as evidenced by three case studies involving research on fire PRA, human reliability analysis (HRA), and pressurized thermal shock (PTS) PRA. These case studies also show that such research can take a considerable amount of time, and that the incorporation of research results into regulatory practice can take even longer. The need for sustained effort and appropriate lead time is an important consideration in the development of a PRA research program aimed at helping the agency address key sources of risk for current and potential future facilities.

A Study on the Development of Evacuation Safety Assessment System on Underground Space (지하공간의 피난안전성평가시스템 개발에 관한 연구)

  • 김진수;박종근;노삼규
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.57-63
    • /
    • 2003
  • In this study; the evaluation system models for evacuation safety assessment of underground malls were presented and related software program was developed. In addition, database was built integrating various data which were essential to evacuation safety assessment and enabling effective safety assessment with low cost and time. As a results of case study in local underground malls, the evacuation safety assessment system has examined in therms of field applicability and reliability.

A Field Survey on the Risk Management Information System on the Underground Space - Focused on Fire Protection Assessment System on The Underground Shopping Mals - (지하공간의 위험관리정보시스템에 관한 조사 연구 - 지하가의 화재예방평가시스템 중심으로 -)

  • Park, Jong-Keun;Roh, Sam-Kew
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.2 no.4 s.7
    • /
    • pp.117-122
    • /
    • 2002
  • A large number of accidents at an underground place have been happening, including the gas explosion under construction of subway, the fires of underground utility and underground shopping malls, and other explosion, at home and abroad recently. These accidents make the function of a city ineffective due to the paralyses of electricity and communications net as well as the loss of property, and cause people to feel unsecured with accompaniment of a heavy of toll of lives. This study suggests safety assessment items and fire protection assessment technique for underground shopping malls by extracting dangerous elements in the management stage through examination of related accidents, documents and present conditions.

A Study on the Application of Fire Risk Assessment Index on the Wooden Cultural Properties -focused on buddhist temples- (목조 건축문화재의 화재위험도 평가지표 및 활용방안 연구 -사찰 건축물을 중심으로-)

  • Kang, Seok-Jin;Ko, Myong-Hwan;Kim, Dong-Jin
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.7
    • /
    • pp.3550-3561
    • /
    • 2013
  • The purpose of this study was to propose the categorized checklist for fire risk assessment on the wooden cultural properties and to carry out field survey. The survey checklist was composed of categories such as management and administration measures(management, training and countermeasure), architectural planning measures(site plan and facility plan), and equipment measures(fire-fighting and crime prevention facility). In this study, the field survey was carried out in the Nae-jang-sa and Wha-um-sa and it was found that there were some problems in the items which were assessed importantly by experts.

A Study on the Electrical Fire Risk Assessment Methods of LED Lightings for Outdoor (옥외용 LED 조명의 전기화재 위험성 평가기법에 관한 연구)

  • Kim, Hyang-Kon;Kim, Dong-Ook;Choi, Hyo-Sang
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.674-679
    • /
    • 2011
  • In this paper, we experimented and analyzed about electric fire risk assessment methods of LED lightings for outdoor. LED lighting is composed of AC power lines, AC/DC converter, DC power lines and LED lamps. There are some risk factors of electric fire in LED lighting such as short circuit between power lines or power line and ground, dielectric breakdown, leakage current, abnormal voltage inflow, poor contacts(connections), etc. As a result of this study, insulation coverings of wire was ignited due to dielectric breakdown between power lines and molten marks were formed in copper conductor. LED lighting was blown out while short circuit, beside that, electrical disorder did not occur. When abnormal voltage was inflowed, electronic components such as varistor, condenser were damaged. Partial heating was produced and insulation was melted and carbonized by arc and heating while poor contacts were happened. We expect that the results of this study would be helpful for electrical safety of LED lightings for outdoor.