• 제목/요약/키워드: Fire response

검색결과 599건 처리시간 0.026초

Mapping을 이용한 소방방재력 및 재해취약성의 연구 (Research on Disaster and Fire Response Capability and Hazard Analysis Using Basic Mapping Method)

  • 왕순주;백민호
    • 한국재난정보학회 논문집
    • /
    • 제3권1호
    • /
    • pp.69-86
    • /
    • 2007
  • The fire department has one of the most important role as public resources of response to disasters in the aspect of supply and the adequate distribution of resources of response is essential, but the distribution of the response capability to disaster of fire department does not reflect the regional hazard vulnerability and hazard risks. Researchers performed database process with simple mapping based on the regional fire disaster response capability and the regional hazard vulnerability and hazard risks. The cities and towns are divided to four types each, total eight types and relative threat ratios are extracted from every type. The fire disaster response capability was extracted from number of firemen and fire vehicles in defined region. The distribution of the fire disaster response capability was inadequate and not matching to relative threat especially in small cities and some types of towns. The regional relative threat and resources should be analyzed by more delicate mapping and software development in the future.

  • PDF

An Analysis of Working Hours by Type of Sprinkler Head Used at Indoor Gymnasiums

  • Ahn, Jae-Cheon;Kong, Ha-Sung
    • International journal of advanced smart convergence
    • /
    • 제10권4호
    • /
    • pp.117-123
    • /
    • 2021
  • This study aims to analyze working hours of sprinkler heads when a fire occurs at an indoor gymnasium while sprinkler heads are installed in division of standard response type, special response type, and earlier response type. The fire scenario was designed under the assumption that the fire started from overheating of a heater in the indoor gymnasium has transferred on to a couch to spread. The analysis on the operation time of the standard response type sprinkler head, the special response type sprinkler head and the early response sprinkler head was conducted. The result showed that, in case of fire in a gymnasium, the time for opening of the heat sensor due to the heat from the fire varies by the type of the sprinkler head. When a special response type sprinkler is installed, it worked below the assessment standards. When an early response sprinkler head is installed, it worked appropriately according to assessment standards. Based on the results, we found that sprinkler heads will work properly when installed according to design relevant to laws and regulations. This means that there is a limit in installation of sprinkler heads based on the existing law-based design as for indoor gymnasiums. Again, we conclude that if sprinkler heads are installed based on design made through laws and regulations, more time will be needed for operation, making it highly likely to fail to stop a fire at an earlier point of time.

화재대응능력 향상을 위한 화재모의훈련의 개선방안에 관한 연구 : 업무시설의 화재모의훈련 중심으로 (A study on the improvement plan of fire simulation training for the improvement of fire response ability : Focusing on the fire simulation training of business facility)

  • 김봉준;류구환
    • 디지털융복합연구
    • /
    • 제18권9호
    • /
    • pp.191-198
    • /
    • 2020
  • 본 연구에서는 화재대응능력 향상을 위한 화재모의훈련의 개선방안을 제안하기 위해 3개의 업무시설물을 대상으로 화재모의훈련을 실시하고 훈련 교보재의 활용 여부와 대응단계별 대응시간의 훈련평가 반영 여부에 따라 변화하는 훈련 참여자들의 대응자세 및 대응능력을 관찰 및 분석하였다. 분석결과 대다수의 훈련 참가자들은 훈련 교보재 활용과 대응단계별 대응시간이 훈련평가에 반영될 때 훈련 참여도, 대응자세 및 대응능력이 향상되는 것으로 분석되었다. 화재모의훈련을 실시할 경우 훈련 참여자들의 화재대응능력(화재통보 및 화재신고, 초기소화, 대피) 향상과 유지를 위해 화재발생 상황을 유사하게 구현할 수 있는 훈련 교보재를 다수 활용하고 각 대응단계별 목표시간을 설정한 후 이를 기반으로 정량적인 훈련평가를 하여야만 화재대응능력 향상과 향후 화재모의훈련의 개선 및 피드백에 유용한 지표로 활용될 수 있다는 결과를 도출하였다.

비상시 개인별 대응행동 (Individual Behavioral Response in an Emergency)

  • 정현규;송용식;조원철;이태식
    • 한국방재학회:학술대회논문집
    • /
    • 한국방재학회 2008년도 정기총회 및 학술발표대회
    • /
    • pp.625-628
    • /
    • 2008
  • The behavioral response of the individuals intimately involved with the initiation of the fire or those who aware of the initial fire cue, often appeared to be a determinant to the outcome of the fire incident, the nonadaptive flight or panic type behavioral response appears to be an infrequent, unusual or unique participant behavioral response in most fire incidents. Therefore, this study focused on the investigation of the individual behavioral responses depend on the distinction of sex and age.

  • PDF

Effect of Fire Induced Spalling on the Response of Reinforced Concrete Beams

  • Kodur, V.K.R.;Dwaikat, M.B.
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권2호
    • /
    • pp.71-81
    • /
    • 2008
  • A macroscopic finite element model is applied to investigate the effect of fire induced spalling on the response of reinforced concrete (RC) beams. Spalling is accounted for in the model through pore pressure calculations in concrete. The principles of mechanics and thermodynamics are applied to compute the temperature induced pore pressure in the concrete structures as a function of fire exposure time. The computed pore pressure is checked against the temperature dependent tensile strength of concrete to determine the extent of spalling. Using the model, case studies are conducted to investigate the influence of concrete permeability, fire scenario and axial restraint on the fire induced spalling and also on the response of RC beams. Results from the analysis indicate that the fire induced spalling, fire scenario, and axial restraint have significant influence on the fire response of RC beams. It is also shown that concrete permeability has substantial effect on the fire induced spalling and thus on the fire response of concrete beams. The fire resistance of high strength concrete beams can be lower that that of normal strength concrete beams due to fire induced spalling resulting from low permeability in high strength concrete.

지하철 차량 방화사고 초기대응에 관한 연구 (A Study on the Early Response System Subway Cabin Arson Fire)

  • 노삼규;함은구;김시곤
    • 한국화재소방학회논문지
    • /
    • 제20권2호
    • /
    • pp.21-30
    • /
    • 2006
  • 2003년 대구지하철 방화사고 이후 서울의 도시철도 7호선 방화를 비롯해 해외에서도 이와 유사한 모방 범죄가 발생하고 있다. 지하철의 방화사고는 대부분 유류나 가스 등을 이용한 방화유형이 대표적으로 발화 후 수분 내에 차량 내부가 전소될 수 있어 궁극적으로 지하철 전노선을 마비시키는 결과를 초래할 수 있다. 따라서 화재발생과 확산을 단계적으로 차단하거나 화재로부터 신속히 격리할 수 있는 효과적 초기 대응의 대안을 제시함으로서 대형 재난을 피할 수 있다. 본 연구에서는 국내외 지하철 방화 사고의 진행과정을 분석하여 대응 단계별로 방화 상태의 피해확인 및 인지 여부, 초기진화 여건 판단, 대응 조직의 상황전파 및 피난유도과정을 비상상황 등급별로 시나리오상에 전개했다.

반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구 (A Study on the Classification of Domestic Fire Detector using Response Time Index)

  • 홍성호;김동석;최기옥
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

화재실험을 통한 주택용 연기감지기 응답특성에 관한 연구 (A Study on the Response Characteristics of the Residential Smoke Detector Depending on Controlled Fire Tests)

  • 사공성호;김시국;이춘하;정종진
    • 한국화재소방학회논문지
    • /
    • 제23권4호
    • /
    • pp.98-103
    • /
    • 2009
  • 본 논문은 연기감지기의 응답특성을 분석하여 주택용 화재감지기로 적합한지를 분석하고자 광전식연기감지기, 아날로그연기감지기, 단독경보형연기감지기를 시험체로 선정하여 UL 268에서 정하는 화재시험방법을 응용하여 화재성상(종이화재와 인화성액체화재)에 따른 연기감지기의 응답특성을 분석하고자 화재실험을 실시하였다. 실험결과 화재성상에 따라 연기감지기의 응답특성 차이가 나타나는 것을 확인할 수 있었다.

오감인지를 통한 지하철 화재 비상대응시스템에 관한 연구 (A Study on the Emergency Response System by Five Sense in the Subway Fire)

  • 노삼규;함은구
    • 한국화재소방학회논문지
    • /
    • 제22권1호
    • /
    • pp.76-83
    • /
    • 2008
  • 지하철 화재사고 경우 정확한 화재 유형 파악과 그에 따른 적절한 초기대응은 사고피해를 최소화하기 위한 중요한 사항이다. 그러나 지하철 화재사고 발생 시 기관사 또는 비상대응직원이 직접 목격하지 않으면 화재 유형을 즉시 파악하기란 불가능하다. 본 연구에서는 화재사고로 나타날 수 있는 오감(五感) 유형을 분석하여 오감 정보를 통해 신속한 화재사고 정보를 전달할 수 있도록 오감 유형을 제안하였다. 또한, 화재 시나리오에 따른 비상대응을 Activity-Action Diagram(AAD)로 정의하여 비상대응을 시스템화 하기 위한 기반을 제시하였다.

소방수요가 소방예산에 미치는 영향 (Impact of Fire Demand on Fire Service Budget)

  • 이원주;임재훈;문광민
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.125-134
    • /
    • 2020
  • 본 연구는 선행연구에서 다뤄지지 않았던 예방소방과 대비소방을 수방수요에 포함시켜 소방예산에 미치는 영향을 실증적으로 분석하고자 수행되었다. 이를 위해 16개 광역자치단체에서 수행된 예방소방행정(건축허가동의, 특정 소방대상물, 다중이용업, 소방특별조사), 대비소방행정(소방교육 및 훈련), 대응소방행정(화재진압출동, 구급출동) 그리고 소방예산에 대한 11년(2008년-2018년)의 패널자료를 이용하여 실증분석을 실시하였다. 분석결과, 예비소방행정의 소방특별조사, 대비소방행정의 소방교육 및 훈련, 그리고 대응소방행정의 화재진압출동은 소방예산에 유의미한 음(-)의 효과가 있는 것으로 나타났다. 한편, 대응소방행정의 구급출동은 0.01%수준에서 소방예산에 유의미한 양(+)의 효과를 미치는 것으로 나타났다. 이는 우리나라 소방행정의 패러다임이 재난수용(복구중심)에서 재난대응(현장대응중심)을 지나 재난대비(대비중심)로 변화되고 있다는 공공정책을 지지하는 연구결과이다.