• Title/Summary/Keyword: Fire resistant

Search Result 267, Processing Time 0.035 seconds

Comparative Study of Beams made up of Fire Resistant Steels (내화강재 적용 단순 보부재의 고온 거동 비교 연구)

  • Kwon, In-Kyu
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.111-112
    • /
    • 2017
  • Fire is very serious condition in steel based structures. Therefore, to enhance the structural stability of columns and beams in high temperatures, fire resistant steels and TMC fire resistant steels are developed from steel manufacturing companies. In this study to evaluate the structural stability and compare the resistant performance, a fire engineering design method was applied and fire resistant steels showed the better performance than other two materials.

  • PDF

A Study on the Flame Resistance Performance and Smoking Characteristics of the Flame-Resistant Paint (방염도료의 방염성능 및 발연특성에 관한 연구)

  • Kim, Hwang-Jin;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.78-83
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF, to find flame resistance performance and smoking characteristics according to principal ingredient and characteristics of fire resistant paint. 45 degree combustion test and smoke density test were conducted to investigate the flame resistance performance and smoking characteristics. According to the 45 degree combustion test, acrylic resin type fire resistant paint showed the most excellent fire resistance performance. And the water soluble fire resistant paint showed better fire resistance performance compare to the solvent soluble paints. Also gloss paint showed better fire resistance performance than the flat paint. Based on the smoke density test, the smoke generation of fire resistant treated specimen of acrylic resin type was least. And the water soluble fire resistant paint generate little smoke than solvent soluble fire resistant paint.

Structural stability of fire-resistant steel (FR490) H-section columns at elevated temperatures

  • Kwon, In-Kyu;Kwon, Young-Bong
    • Steel and Composite Structures
    • /
    • v.17 no.1
    • /
    • pp.105-121
    • /
    • 2014
  • A fundamental limitation of steel structures is the decrease in their load-bearing capacity at high temperatures in fire situations such that structural members may require some additional treatment for fire resistance. In this regard, this paper evaluates the structural stability of fire-resistant steel, introduced in the late 1999s, through tensile coupon tests and proposes some experimental equations for the yield stress, the elastic modulus, and specific heat. The surface temperature, deflection, and maximum stress of fire-resistant steel H-section columns were calculated using their own mechanical and thermal properties. According to a comparison of mechanical properties between fire-resistant steel and Eurocode 3, the former outperformed the latter, and based on a comparison of structural performance between fire-resistant steel and ordinary structural steel of equivalent mechanical properties at room temperature, the former had greater structural stability than the latter through $900^{\circ}C$.

A Study on Prediction Techniques about Fire Resistance of Modular Beam in ISO Fire (표준화재조건 모듈러보 내화성능 예측기법에 관한 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kim, Gyeong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.518-523
    • /
    • 2008
  • The modular beam made of steel material is wholly responsible for the load stress of the structure, therefore securing the fire-resistant capacity of the steel beam is absolutely important. The economic efficiency achieved by minimizing the thickness of the fire-resistant board attached, is also essential at the same time. Accordingly, a study of optimization of the thickness and interval of fire-resistant boards shall be conducted side by side. Therefore, in this study we have anticipated fire-resistant capacity by using a general-purpose S/W for finite elements, ABAQUS(6.7.1), in order to propose the configurable conditions that can secure the optimal fire-resisting capacity of modular beam. As a result of this analysis, it was impossible to secure the fire-resistance capacity when directly attaching fire-resistant board(30mm) on the modular board in accordance with KS F 2257-1, and the fire-resistant boards were manufactured in shape of module in consideration of its installation interval rather than direct application.

  • PDF

Fire Spreading Prevention of Straw-roofing House in Folk Village by Flame Resistant Treatment (민속마을 초가집의 방염에 의한 화재확산방지)

  • Park, Ho-Chun;Kim, Hwang-Jin;Lee, Seung-Hyun;Lee, Sung-Eun;Oh, Kyu-Hyung
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.52-57
    • /
    • 2010
  • Fire protection countermeasure were considered on the straw thatched roof and wooden structure. For the fire resistant treatment, rice straw was soaked in the fire resistant liquid with different soaking time. After treatment, some rice straw sample was washed with water then the rice straws were tested to check the fire resistance performance. And the wood was soaked in the fire resistant liquid at an atmospheric pressure, vacuum-pressure condition and painted with brush on the surface. To analyse the fire resistant performance of rice straw, ignition delay time was measured under the radiant heat flux of cone heater. And the fire resistant performance of wood samples were tested with 45 degree fire resistant test apparatus and cone heater. Based on the cone heater test, the rice straw which most easily ignitable material shows the longer ignition delay time than not treated ones and even in the water washed straw show a longer ignition delay time than not treated ones. And fire resistant treated woods of vacuum-pressure treated sample showed the most excellent performance on fire resistance. And the fire resistant treated by brush and soaking showed a longer ignition delay time than not treated ones. From this experiment, it was found that a fire resistant treatment of rice straw and wood of the house can be protected from the fire spread.

A Study for Structural Stabilities of Beams Built with TMC Fire Resistant Steels by Analytical Method at High Temperatures (해석적 방법에 의한 TMC 건축용 내화강재 적용 보부재의 고온 내력평가 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.31 no.6
    • /
    • pp.60-66
    • /
    • 2017
  • Steel framed building can be destroyed due to deteriation of structural stabilities in a fire. This leads a TMC Fire Resistant Steels and this study analyzed the structural stabilities such as a deflection and a reduction of maximum load capacity for the structural beams built with a TMC Fire Resistant Steel. In this study the structural stabilities were evaluated using a mechanical properties in high temperatures not only a heat transfer theory but a heat stress anlaysis with a statistically determinated beam and a statistially indeternated one. The results showed that a TMC Fire Resistant Steels demonstrated a little lower those of Fire Resistant Steels.

Study on Physical Properties of Mortar Using Eggshell Powder for Filler (계란 껍데기 분말을 채움재로 활용한 모르타르의 물리적 특성에 관한 연구)

  • Seo, Eun-Seok;Kim, Bong-Joo;Hong, Sang-Hun;Kim, Han-Nah;Jung, Ui-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.75-76
    • /
    • 2020
  • Use fire resistant construction methods, of which fire resistant boards are used to protect buildings and structures from fire. However, in the case of fire resistant boards, the unit price of the main raw material is high and the cost efficiency is low. There have been studies to apply oyster shells to fire resistant boards to solve these problems. On the other hand, egg shells are also considered to be applicable to fire-resistant boards with components like oyster shells, but there is no case of using egg shells as building materials. Therefore, in this study, we confirmed the physical properties of egg shell powers used as mortar filler and compared them with the fire resistant board flexural strength standard. As a result, it was judged that the powder of egg shells could be used as a building material, because the standards for the flexural strength of fire resistant boards were satisfied except for a part.

  • PDF

Evaluation on the Mechanical Properties of Fire Resistant Steels at High Temperature Conditions with Manufacturing Processes (제조 방식에 따른 건축용 내화강재의 고온 시 기계적 특성 평가)

  • Kwon, In Kyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.2
    • /
    • pp.181-190
    • /
    • 2007
  • A fire-resistant steel with enhanced load-bearing capacity has been developed to enable structural elements such as columns and beams withstand exposure to severe fire conditions. To precisely evaluate the fire-resistant performance of structural elements that compose fire-resistant steels, mechanical properties such as yield strength and elastic modulus are essential. To obtain the mechanical database of fire-resistant steels at high temperatures, tensile tests at high temperatures were conducted on steels of two kinds of thicknesses. The results showed that the thickness difference could not affect the mechanical properties at a high temperature.

A practical approach for fire safety design of fire-resistant steel members

  • Li, Guo-Qiang;Ding, Jun;Sakumoto, Y.
    • Steel and Composite Structures
    • /
    • v.5 no.1
    • /
    • pp.71-86
    • /
    • 2005
  • Based on the test data of Nippon Steel Corporation, the formulas for calculating mechanical properties of fire-resistant (FR) steel at elevated temperatures have been established. A practical approach for fire safety design of FR steel members, including axially compressed members, flexural members and eccentrically compressed members, is developed in this paper. Compared with the full-scale specimen experiments and FEM numerical analysis, this practical approach for fire safety design of FR steel members is demonstrated to be effective and precise.

강구조 내화성능의 이론적 평가방법에 관한 조사연구

  • Seong, Si-Chang
    • Fire Protection Technology
    • /
    • s.20
    • /
    • pp.42-47
    • /
    • 1996
  • Prior to real fire test, theoretical of the fire resistant performance of the structural ele-ments is often less time consuming and less costly to calculate it, than to determine the perform-ance experimentally. This study is aimed at introduction of estimating methods of the fire resistant performance of the steel structural elements not by the actual fire tests but by the mathematical models.

  • PDF