• Title/Summary/Keyword: Fire protection system management

Search Result 137, Processing Time 0.028 seconds

A Study on Real Condition Estimation for Fire Protection Safety Management System Builds (소방안전경영시스템 구축을 위한 실태평가에 관한 연구)

  • Kang, Gil-Soo;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.18-24
    • /
    • 2013
  • Goverment and enterprises have been devoting a lot of dffort in order to prevent the loss of human and property due to a large, diversified fire, explosion, global warming and disasters caused by natural phenomena. But Enterprises came forward and running in the economy priority policy for profit-seeking until now in order to meet the macro purpose of quality improvement of national life and welfare promotion in company with National growth, as a result of lax risk management have had to endure the loss of precious lives and property. According to the '2007 Survey of public safety for the activation of the safety culture' of National Emergency Management Agency [NEMA], a insensitivity of safety in our society was surveyed 'a serious level'. In this study, surveyed need of 'step-by-step fire protection safety management system builds' in order to prevent fire safety accident and improvement of safety awareness level through a systematic management and real condition estimation of not only large business that can control risk management, but also small business that has a big risk to occur accident easily according to small budget and organization.

A Study on Authoritativeness of Electric Fire by Activating of Fire Damaged MCCB (소손된 배선용 차단기 동작상태에 의한 전기화재 규명의 신뢰성에 관한 연구)

  • Lee, Jong-Hwa;Mun, Yong-Soo;Kong, Ha-Sung
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.87-94
    • /
    • 2009
  • In the fire there are fusion signs and damage by fire, and insulation aging and carbonization of the electric wiring in the ignition spot because of special characteristic of the appliance in the electricity fire. Because of the physical factor applied in the damage of fire, the decision of ignition spot by eye investigation is insufficient. In this paper, the cause of electricity fire is researched. The focus is on the operation state of operated MCCB(Molded Case Circuit Breaker) at the time of electricity fire. Through grasping the operation principle of MCCB and the experiment, the state of MCCB after fire suppression is discriminated. The distinction possibility on the exist of electricity fire is proposed.

FIRE PROTECTION FOR PETROCHEMICAL PLANT

  • Suh, Jung-H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.244-251
    • /
    • 1997
  • Since 1970s, The Petrochemical Industry in Korea has grown rapidly by the successful economic growth. While the process became larger and more complex, hazardous chemicals have been used in large quantity, Therefore, the risk of a major accident such as fire, explosion and toxic material release has been increased. Korea has been ranked the fifth in petrochemical product capacity worldwide, also required to meet international standards on process safety management. Fire Protection System integral part of safely management in Petrochemical Plants, will be reviewed.

  • PDF

A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities (효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구)

  • Son, Gae-Seong;Choi, Ji-Hun;Choi, Don-Mook
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

A Study on the Problems and Character for Management of Fire Prevention at the Wholesale Markets (도매시장 화재안전관리 측면에서의 특성 및 취약요소에 관한 연구)

  • Park, Jae-Sung;Im, Jae-Keun
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.150-158
    • /
    • 2010
  • There are lots of buildings with their deterioration in wholesale markets which have high concentration that can cause big fire due to difficulty of installing fire protection system in fire compartment, absence of safety awareness, access by many and unspecified people. There had been big fire that caused by these kind of fire weakness such as Seomun Market's in 2005 which costed tens of millions dollar, Dongmun Shopping District’s with 7 casualties. Now counter-measure against these fire is urgently needed. This study drew characteristic of current condition of wholesale markets and the one classified by main agent, fire cases and prevention of fire through statistical data. Also, current condition of fire prevention management and actual state were investigated by conducting a survey of person in charge of fire prevention and current practician. As a result, it was shown that securing professionalism of fire prevention, improvement of structural weakness of buildings, obtaining reliability on performance of fire protection system and internal fire education against practician in the market are needed.

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor Factory (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계)

  • Han, Su-Jin;Kang, Kyung-Sik
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2006.11a
    • /
    • pp.325-336
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room (FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design (PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

  • PDF

Fire Hazard Analysis and Performance Based Fire safety Design for the Clean Room in Semiconductor factory(1) (반도체공장 Clean Room에 대한 화재요인 분석 및 성능위주 화재안전설계(1))

  • Han, Su-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.8 no.5
    • /
    • pp.211-229
    • /
    • 2006
  • This research analyzes clean room major fire prevention standard of clean Room(FM, IRI, and NFPA Code), the structure of Performance-Based Fire Safety Design(PBD) applied the korean fire industry situation. Performance-Based Fire Safety can operate effectively the performance of fire protection equipment & building design, so the fitness of fire safety system can be embodied by operating this. moreover, cost to be consume fire safety of real building can reduce and Performance-Based Fire Safety is considered to important technique in fire protection field. A fire in a clean room may cause a serious loss by spreading smoke particles. We will be investigated by using a computational fluid dynamics, for loss prevention by smoke spreading from one fire area to another for clean room and compared the Performance-Based Fire Safety Design with the prescriptive code design. The methodology of fire safety performance-based fire safety design and guarantee of many kinds design skill of fire system and developing design procedure will be very serious one in order to improve efficiency of domestic system. Therefore, This research will be contributing to secure safety of clean room and to set up the performance-based fire safety design in Korea by regulation for the performance-based fire safety design effectively.

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

Study of the Real Condition and Improvement Plans of a Fire Protection System Installed at Museum Storage (수장고에 설치된 소방시설의 실태 및 개선방안에 관한 연구)

  • Park, Jong-A;Joo, Seung-Ho;Kang, Eun-Soo;Lee, Dae-Keon
    • Fire Science and Engineering
    • /
    • v.32 no.3
    • /
    • pp.60-66
    • /
    • 2018
  • Museum storage has been a unique area for experts, such as curators and managers etc., is a part that requires attention among the recent changes in museums because of changes to a type that is being opened gradually to visitors. On the other hand, there is an increased the risk of a fire according to negligence etc. of visitors. Hence, appropriate measures for a fire protection system to respond to varying museum storage are required. This study examined the status of fire protection systems applied to museum storage visiting 40 domestic public museums with the support of the Ministry of Culture, Sports and Tourism, and a direction to install a fire protection system was presented by drawing cases of fire protection systems with less adaptability or poor management or excellent fire protection systems, and a direction for improvement was presented.

A Study on the Efficient Countermeasure of the Serious Accidents Punishment Act in the Small Businesses: On the Basis of the Serious Industrial Accidents (소규모 사업장의 중대재해처벌법 효율적 대응방안 연구 - 중대산업재해 중심)

  • Lee, Byoung-Lim;Choi, Yu-Jung;Yoo, Sam-Yeol;Choi, Jae-Wook
    • Journal of the Society of Disaster Information
    • /
    • v.18 no.3
    • /
    • pp.507-519
    • /
    • 2022
  • Purpose: This study propose efficient and practical measures to comply with the duty to secure safety and health of the Serious Accidents Punishment Act at small businesses. Method: Based on literature review and previous studies, a plan to comply with the Serious Accidents Punishment Act was reviewed by the link with the safety and health management system and using the process approach method, etc. Result: It was confirmed that if the safety and health management system is faithfully implemented, it is possible to comply with the duty to secure safety and health under the Serious Accidents Punishment Act. In addition, a methodology for fulfilling and inspecting the duty to secure safety and health was presented. Conclusion: If the safety and health management system is operated actively by utilizing the process approach and implementation inspection checklist, it is judged that it will be possible to comply with the Serious Accidents Punishment Act as well as to continuously improve the safety and health management system.