• Title/Summary/Keyword: Fire protection safety

Search Result 634, Processing Time 0.03 seconds

Research on no coal pillar protection technology in a double lane with pre-set isolation wall

  • Liu, Hui;Li, Xuelong;Gao Xin;Long, Kun;Chen, Peng
    • Geomechanics and Engineering
    • /
    • v.27 no.6
    • /
    • pp.537-550
    • /
    • 2021
  • There are various technical problems need to be solved in the construction process of pre-setting an isolation wall into a double lane in the outburst prone mine. This study presents a methodology that pre-setting an isolation wall into a double lane without a coal pillar. This requires the excavation of two small section roadways to dig a wide section roadway, followed by construction of the separation wall. During this process the connecting lane is reserved. In order to ensure the stability of the separation wall, the required bearing capacity of the isolation wall is 4.66 MN/m and the deformation of the isolation wall is approximately 25 cm. To reduce the difficulty of implementing support the roadway is driven by 5 m/d. After the construction of the separation wall, the left side coal wall is brushed 1.5 m to make the width of the gas roadway reach 2.5 m and the roadway support utilizes anchor rod, ladder beam, anchor cable beam and net configuration. During construction, the concrete pump and removable self-propelled hydraulic wall mold are used to pump and pour the concrete of the isolation wall. In the process of mining, the stress distribution of coal body and isolation wall is detected and measured on site. The results demonstrate that the deformation of the surrounding rock of roadway and separation of roof in the roadway is small. The stress of the bolt and anchor cable is within equipment tolerance validating their selection. The roadway is well supported and the intended goal is achieved. The methodology can be used for reference for similar mine gas control.

Improvement of Citadel Structure on Board Ship Using FDS (화재 시뮬레이션을 이용한 선원대피처의 구조 개선에 관한 연구)

  • Kim, Won Ouk;Kim, Jong Su;Park, Woe Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.3
    • /
    • pp.306-311
    • /
    • 2015
  • Recently, vessel hijacking by pirates has been a big issue around the world. In case of the hostages of M/V "SAMHO Jewelry" on January 20, 2011, the Korean Navy has rescued 21 seafarers by first naval operation with somalia pirates since establishment of the Navy. Also, in case of the "HANJIN Tianjin", all crews evacuated to the Citadel promptly when being attacking by pirates and were safely rescued by the navy. By the accident, Necessity of Citadel for seafarer on board ship came to the fore against pirates. Taking in account increasing pirates accident at sea, many research relating to pirates has been implementing with a view to responding to them so far. By amending the ship facility regulation in the domestic law on Jan. 2011, the installment of Citadel on board ship became mandatory for ocean going vessel serving pirates area. Hence, this paper provides new model of Citadel structure based on an Fire Dynamic simulation in order to improve personal safety in case of vessel hijacking.

The Ventilation Plane Due to Smoke Driving Combined Forces in Super High-Rise Buildings (초고층 건물에서 연기이동 복합력에 의한 환기계획)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.82-87
    • /
    • 2016
  • The ventilation system for the efficient operation of the building services systems in the ventilation plan of super high-rise buildings is used to combine smoke control systems. This study evaluated models of super high-rise buildings with four basement levels and 59 stories and investigated the pressure distribution of each floor by the smoke driving forces by numerical analysis. The smoke driving forces on the building of analytical model was analyzed to determine the effects of the ventilation plan and smoke control plane. In addition, when a combination with ventilation and smoke control of the kitchen ventilation damper in the ventilation plan of analysis model building was designed based on the these results, the relationship between the opening and closing force of the damper and smoke driving combined forces to act on the design pressure of the damper by a motion analysis simulation. The driving units of the damper were selected from the analytical results.

Publics Segmentation by the Issuance of Disaster-related Crisis Alert (재난 관련 위기경보 발령에 따른 공중유형 분류에 관한 연구)

  • Kim, Yong-Soon;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.91-99
    • /
    • 2020
  • Recently, a new infectious disease, COVID-19, has been spreading not only in Korea but around the world. As a result, the Korean government raised the level of infectious disease crisis alerts to a serious level on February 23, 2020. The purpose of this study is to apply the situational theory of publics to publics segmentation according to the issuance of a crisis alert and to suggest ways to improve the crisis alert system. To this end, the level of public perception on crisis alerts was checked. The verification confirmed that the situational theory of publics is a suitable theoretical framework for analyzing the communication behaviors of the public toward crisis alerts. As a result of the public segmentation, 42.7% were classified as active publics. Based on this, it was suggested to reorganize the crisis alert system as a system for communicating with the public.

A Study on the Risk of Spontaneous ignition to Butadiene Popcorn Polymer (Butadiene Popcorn Polymer의 자연발화 위험성에 관한 연구)

  • Koo, Chae-Chil;Lee, Jung-Suk;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.33 no.2
    • /
    • pp.1-8
    • /
    • 2019
  • This study was conducted to investigate the possibility of spontaneous ignition in Butadiene popcorn polymer, which is used as raw material and product in a chemical plant. A component analysis, thermogravimetric analysis, thermal stability analysis, spontaneous ignition point measurement and accelerated velocity calorimetric analysis were performed. As a result of analysis, various kinds of flammable components were measured and thermogravimetric analysis showed a weight loss of 95.6% in air and 89.2% in nitrogen. As a result of the thermal stability analysis, heat generation started at $88^{\circ}C$ in the air atmosphere, and the heat generation rate increased sharply in the vicinity of the natural ignition point ($220^{\circ}C$). The heat generation started at about $70^{\circ}C$ in nitrogen atmosphere, and the two exothermic peak values were observed up to $450^{\circ}C$. As a result of accelerated rate calorimetry, there was no exothermic phenomenon, and the lowest ignition temperature was $211.7^{\circ}C$ as a result of analysis of natural ignition point. Based on the results obtained from the thermal stability evaluation, it is considered that the possibility of inducing the thermal deformation of the column by the heat of reaction is sufficient.

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

Development of a Standard Checklist for Protection to Electrical Accidents of Laboratory (연구실 전기사고방지를 위한 표준체크리스트개발)

  • Lee, Dong-Yoon
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.3
    • /
    • pp.108-115
    • /
    • 2011
  • This paper informs the standard guideline of electrical inspection for the University laboratories and R&D institutes. A routine electrical inspection is there to prevent an electric shock and electrical fire accident in the Lab. The main issue of this paper is to check the problem of a routine electrical inspection and this paper provides a detailed guideline of a checklist for the Lab which do not have detailed instruction. It mentions the standard model of an effective routine inspection to upgrade the weak electrical environment in the Lab. One of the main purposes of this paper is to develop a routine checklist to control the electrical environment in the Lab. The evaluation checklist we develop will then be applied to every Lab. Introducing an electrical safety checklist builds a clear standard guideline for a real safety check. This will be used as a regular routine check-up for every Lab. The goal of this paper is to enforce safety from electrical accidents in the lab and it will provide safety guidelines for every Lab.

A Study on the Improvement of Port State Control in Korea (우리나라의 항만국통제 제도의 개선에 관한 연구)

  • 박병곤;정재용;박진수
    • Journal of the Korean Institute of Navigation
    • /
    • v.23 no.4
    • /
    • pp.43-61
    • /
    • 1999
  • To ensure ship's safety and preserve the marine environment from ship, IMO(International Maritime Organization) has been making much efforts. Nevertheless there are still many possibilities threatening ship's safety and the marine environment. Many vessels navigate at sea in lack of standard required by the International Convention relevant to ship's safety and the protection of marine environment. Even though the administration is responsible for perfect and continuous control for safety of ship, it cannot has jurisdiction over ships hoist its flag reasonably at all times. So the Port State has strengthened the Port State Control(PSC) activity as one step of eliminating sub-standard vessels. In the light of the fact that mentioned above, this study deals with PSC activity in Korea and port of Pusan. Total 582 ships, inspected in port of Pusan from 1st January 1998 to 30th September 1999, were analyzed in various aspect and extracted results as follows : \circled1 The inspection rate in Korea was much lower than the other states taking part in Tokyo MOU, \circled2 For flag state, the ships belong to flag of convenience(FOC) had much more deficiencies than non-convenience flag ships, \circled3 For ship type, 39 number of general dry cargo ship were detained at Pusan with serious deficiencies, \circled4 For deficiency item, the items such as life saving appliances, safety in general, navigation, load lines and fire-fighting appliances were occupied over 71.7% of total number of deficiencies, \circled5 In Asia-Pacific region, Korea was one of flags with detention percentages exceeding 3-year(1996~1998) rolling average detention percentage. Average detention rate of Korean vessels was 6.73% which was over 0.24% of average detention rate(6.49%) in Asia-Pacific region. These results may reflect to improve the performance of PSC inspection for foreign vessels and are useful for preparing PSC inspection for ocean-going ships registered in Korea.

  • PDF

On-Site Diagnosis of Fire Blight with Antibody-Based Diagnostic Strips (항혈청 기반 진단 스트립을 이용한 과수 화상병 현장진단)

  • Heo, Gwang-Il;Shin, Doo-San;Son, Soo-Hyeong;Oh, Chang-Sik;Park, Duck Hwan;Lee, Young-Kee;Cha, Jae-Soon
    • Research in Plant Disease
    • /
    • v.23 no.4
    • /
    • pp.306-313
    • /
    • 2017
  • Recently fire blight occurred in the Republic of Korea and eradication program for the disease has been executed since then. Specificity and detection sensitivity of the 2 antibody-based diagnostic strips to Korean isolates of Erwinia amylovora (Ea) and their application for on-site diagnosis were evaluated in this study. Ea AgriStrip, a commercial diagnostic kit, and EB strip, developed in this study, reacted positively to the all tested Korean Ea strains and also to most of Erwinia pyrifoliae (Ep) strains causing black shoot blight. They reacted negatively to all Pusedomonas syringae pv. syringae (Pss) strains that cause shoot blight on apple. Detection sensitivity was similar between the 2 strips. For on-site diagnosis, the two strips reacted positively only to the extractions of the fire-blighted samples on all fire blight occurred orchards except one orchard at which on-site diagnosis was carried out at winter time. In addition, they reacted positively to the black-shoot blighted extractions from the black shoot blight occurred apple orchard. These results suggest that both EB strip and Ea AgriStrip would be useful for on-site diagnosis of fire blight in Korea.

A Study on Visual Comfort for Light Control Method of Applied Daylighting (자연채광방식의 응용에 따른 시각적 쾌적성에 관한 연구)

  • Han, Sang-Pil;Han, Sang-Cheol
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.140-145
    • /
    • 2012
  • The purpose of this study is to understand the change of impression by comparing the uniformity lighting with the compound lighting. In previous study, we proposed a light controlling method to harmonize daylight from a window and artificial lights from a ceiling and obtained the results to support our method. We referred this method as the Adjusted Compound-Lighting Model (AC Model). The model claims that lighting in a room with a side-window are perceived as harmonious when the overall light distribution in the room is well approximated by a compound of lights from the window and the entire ceiling. The experiment is carried out with the scaled-models and mock-up spaces that were supposed to be an office space. One is lit by the uniform lighting and the other by the compound lighting in each experimental space. In order to present varying illuminance distributions, thetwo variables were used in this study. One was the ratio of thelight from the window and ceiling in the standard and evaluation box. The standard box was provided by the ratio of 20% to 40% from the window and 80% to 60% from the ceiling as two lighting ratio patterns [Wu20(=Cu80) and Wu40(=Cu60)]. And the evaluation box was provided by the light ratio of 0% to 40 from the window and 100% to 60% from the ceiling [Wcp0(=Ccp100), Wcp20(=Ccp80) and Wcp40(=Ccp60)]. The other variable was themean illuminance level in both boxes. Two level of mean illuminance (700lx and 300lx) were used in this experiment. Each lighting condition was established at equal horizontal mean illuminance level, held constant near 700lx or 300lx in both boxes. Both of them were similar in the shape of distribution when there were same ratios of lights from the window and the ceiling. Subjects were asked to evaluate the point of difference by semantic differential rating on their overall impression after comparing with two rooms. The results showed that the impressions of compound lighting were more positive score than that of uniformity lighting on the items of 'dim-bright', 'dislike-like', 'artificial-natural' and 'closed-open', and that there was no significant difference in impressions between two spaces on other items.

  • PDF