• Title/Summary/Keyword: Fire protection safety

Search Result 643, Processing Time 0.024 seconds

Vital Area Identification of Nuclear Facilities by using PSA (PSA기법을 이용한 원자력시설의 핵심구역 파악)

  • Lee, Yoon-Hwan;Jung, Woo-Sik;Hwang, Mee-Jeong;Yang, Joon-Eon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • The urgent VAI method development is required since "The Act of Physical Protection and Radiological Emergency that is established in 2003" requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The VAI methodology is developed to (1) make a sabotage model by reusing existing fire/flooding/pipe break PSA models, (2) calculate MCSs and TEPSs, (3) select the most cost-effective TEPS among many TEPSs, (4) determine the compartments in a selected TEPS as vital areas, and (5) provide protection measures to the vital areas. The developed VAI methodology contains four steps, (1) collecting the internal level 1 PSA model and information, (2) developing the fire/flood/pipe rupture model based on level 1 PSA model, (3) integrating the fire/flood/pipe rupture model into the sabotage model by JSTAR, and (4) calculating MCSs and TEPS. The VAT process is performed through the VIPEX that was developed in KAERI. This methodology serves as a guide to develop a sabotage model by using existing internal and external PSA models. When this methodology is used to identify the vital areas, it provides the most cost-effective method to save the VAI and physical protection costs.

Study on building room fire development stages (건축물 실내화재의 단계에 대한 연구)

  • Cha, Jong-Ho
    • 한국방재학회:학술대회논문집
    • /
    • 2008.02a
    • /
    • pp.169-172
    • /
    • 2008
  • The purpose of this paper is to summarize characteristics of fire growth stages, combustion proceeding, human behavior factors against fire, fire active protections, fire alarms in order to perform public safety and protection, personnel property protection, with identification of economic analysis aspects based on respective stages classified as fire generation- fire growth- flashover- fire extinction, which is differ from previous studies that based on distinct concepts such as fire stages, escapes, building construction, fire sensing.

  • PDF

A Study on the Fire Spread between Office Room and Atrium in the Atrium Building (아트륨 빌딩에서의 사무실과 아트륨간의 화재확산에 관한 연구)

  • Lee, Su-Kyung;Kim, Jong-Hoon
    • Journal of the Korean Society of Safety
    • /
    • v.15 no.2
    • /
    • pp.78-83
    • /
    • 2000
  • Generally, There is to install fire resist shutter or to compart between the office room and the atrium in the atrium buildings in Korea. But, Glass wall that is installed sprinkler which purpose to protect it from fire, is already installed between the office room and the atrium in the advanced nations. We study this problem as follow; We made the fire scenario, and analyze each scenario using FASTLite is fire modeling software and BREAK1 is to predict the window breakage time in the compartment fire. In this study, we can decide that fire compartmentalization between atrium and office rooms doesn't require in Atrium building if the material and fire protection system were reliable. Consequently, Korean Fire Protection Regulations have to consider in direction of increasing freedom of building.

  • PDF

Fire Risk Assessment of Building Use Types Using Natural Breaks (Jenks) (자연적 구분법을 이용한 건축물 용도별 화재위험도 평가)

  • Lee, Kyu Min;Lim, Hyeon Seok;Cho, Jae Woo;Lee, Sang Kwon;Min, Se Hong;Min, Jeong Ki
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.63-71
    • /
    • 2019
  • This study quantitatively analyzed the fire risk of buildings by use nationwide, fire occurrence, and the statistical data of buildings by use. Fire incidents and buildings' statistics from the past 10 years (2008-2017) were used and classified as "Building Laws" and "Enforcement Decree of the Act on the Installation, Maintenance, and Safety of Fire Facilities" to be used for the relative assessment under the Natural Breaks as a risk matrix. In addition, after conducting risk assessment using 2018 fire occurrence data, we compared and analyzed the same with past 10 years' data. The results showed that most facilities had similar risk grades, except for the results of reduced risk levels from IV to II in recreational facilities, confirming the past and present data correlations as valid. Hence, the classification method is deemed appropriate. Through the results, the fire risk assessment of buildings by use nationwide are presented as a reference for fire safety.

An analysis of a backdraft using FASTLite (FASTLite를 이용한 backdraft 사고의 해석)

  • Kim, Jin-Guk
    • Fire Protection Technology
    • /
    • s.22
    • /
    • pp.9-16
    • /
    • 1997
  • This paper has two objectives. One is to introduce a software package, "FASTLite" for fire safety engineering calculation, the other to show the modeling result of a backdraft incident on the 62 WATTS street. A classic backdraft usually persists only seconds before exhausting their fuel supply but in this case the flame had persists for at least 6 and a half minutes. It is truly necessary to find out where the fuel came from to feed this flame for so long. The backdraft is successfully modelled by using FASTLite. To help understanding of this backdraft, the calculation with the door open is also carried out and compared to the backdraft.

  • PDF

A Study on the Escape capacity for Evacuation safety Design of PBD foothold in Korea(II) (국내 PBD기반 피난안전설계를 위한 피난용량 산정에 관한 연구(II) - 멀티플렉스 공간의 재실자밀도 조사 -)

  • Jo, Nam-Hun;Seo, Dong-Goo;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.210-215
    • /
    • 2008
  • As the rapid and various changing of social aspects, the structures are getting bigger, higher and more complex. The importance of evacuation is on the rise as increased using frequency of multiplex area and it's high population density. According to the result of a survey with 2 domestic multiplex population density, the maximum was 0.43(人/$m^2$) and 0.51(人/$m^2$). considering evacuation dangerousness, the maximum value will be suitable for computation of evacuation capacity and this will be submitted as a basic data for computation of evacuation capacity.

  • PDF

Development of Inorganic Fire Protection Materials for High Strength Concrete (구조체 보호를 위한 고내화성 마감재 적용에 관한 실험적 연구)

  • Jung, Suk-Jo;Song, Hun;Kwon, Choon-Woo;Kim, Young-Yup;Chu, Yong-Sik;Lee, Jong-Kyu
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.885-888
    • /
    • 2006
  • Nowaday, High strength concrete(HSC) has been mainly used in high rise building. HSC have superior property as well as improvement in durability compared with ordinary strength concrete. In spite of durability of HSC, explosive spalling in concrete front surface near the source of fire occurs serious problem in structural safety. Thus, this study is concerned with experimentally investigation fire resistance of the inorganic fire protection materials at high temperatures up to $800^{\circ}C$. From the test result, developed inorganic binder becomes general that with rising temperature the compressive strength of the material increases in tendency. Therefore, the results indicate that it is possible to fireproof panels, fire protection of materials, etc.

  • PDF

A Study on the Development of Tester for the Field Inspection of the Rate of Rise Spot Type Heat Detector (차동식열감지기 현장점검용기기 개발에 관한 연구)

  • Kim, Shi-Kuk;Lee, Chun-Ha;Jee, Seung-Wook;Yuk, Hyun-Dai;Yang, Seung-Hyun
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2009.04a
    • /
    • pp.200-209
    • /
    • 2009
  • 본 논문은 차동식스포트형열감지기 현장점검용기기 개발에 관한 연구이다. 현재 소방점검 시 차동식스포트형열감지기의 성능확인을 위해 사용되는 점검기기(4 Type)들을 실험대상으로 선정하여 문제점을 찾고, 도출된 문제점을 바탕으로 감지기 형식승인 시 감도시험기준 조건과 동일한 온도조건인 주위온도 대비 30$^{\circ}C$ 높은 온도로 자동설정 할 수 있는 기능과 그 온도를 계속 유지할 수 있는 기능을 갖춘 새로운 차동식스포트형열감지기 현장점검용 기기의 시제품을 제작하고 그 성능을 확인하였다.

  • PDF