• Title/Summary/Keyword: Fire protection safety

Search Result 643, Processing Time 0.018 seconds

Analysis of Effect of Surface Temperature Rise Rate of 72.5 Ah NCM Pouch-type Lithium-ion Battery on Thermal Runaway Trigger Time (72.5 Ah NCM계 파우치형 리튬이온배터리의 표면온도 상승률이 열폭주 발생시간에 미치는 영향 분석)

  • Lee, Heung-Su;Hong, Sung-Ho;Lee, Joon-Hyuk;Park, Moon Woo
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.5
    • /
    • pp.1-9
    • /
    • 2021
  • With the convergence of the information and communication technologies, a new age of technological civilization has arrived. This is the age of intelligent revolution, known as the 4th industrial revolution. The 4th industrial revolution is based on technological innovations, such as robots, big data analysis, artificial intelligence, and unmanned transportation facilities. This revolution would interconnect all the people, things, and economy, and hence will lead to the expansion of the industry. A high-density, high-capacity energy technology is required to maintain this interconnection. As a next-generation energy source, lithium-ion batteries are in the spotlight today. However, lithium-ion batteries can cause thermal runaway and fire because of electrical, thermal, and mechanical abuse. In this study, thermal runaway was induced in 72.5 Ah NCM pouch-type lithium-ion batteries because of thermal abuse. The surface of the pouch-type lithium-ion batteries was heated by the hot plate heating method, and the effect of the rate of increase in the surface temperature on the thermal runaway trigger time was analyzed using Minitab 19, a statistical analysis program. The correlation analysis results confirmed that there existed a strong negative relationship between each variable, while the regression analysis demonstrated that the thermal runaway trigger time of lithium-ion batteries can be predicted from the rate of increase in their surface temperature.

Study on Exposed Piping with High Risk of Fire (화재 위험성이 높은 노출배관 사용에 관한 연구)

  • Kim, Yeob-Rae;Baek, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.61-66
    • /
    • 2015
  • PVC pipe has excellent corrosion resistance and chemical resistance and is broadly used. However there are no regulations regarding exposed piping material in buildings. There is growing concern about the vulnerability of piping to fires and generating toxic gas. Exposed piping should be made of incombustible materials to prevent spreading of toxic gas and to minimize damage to life and property in case of fire. Many big structures are being built, and concerns regarding damage by fire are continuously growing. In these circumstances, we should reinforce fire safety standards for buildings and heighten safety consciousness to become a well-developed country. For these reasons, we investigated the materials used for exposed piping and the standards of well-developed countries to enhance safety. We tried to figure out the alternatives by examining the actual conditions of each region's buildings. Based on the use of incombustible materials for exposed piping in each region, we tried to enhance the effectiveness for safety by suggesting revisions for related laws and regulations.

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

Characteristic Analysis and Configuration of the Protection System to Improve the Safety of the BIPV System (BIPV 시스템의 안전성 향상을 위한 보호시스템 구성 및 특성 분석)

  • Seok-Hwan Cho;Jae-Sub Ko;Dae-Kyong Kim
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.3
    • /
    • pp.591-599
    • /
    • 2024
  • This paper presents the configuration and characteristic analysis of the protection system to improve the safety of the building integrated photovoltaic(BIPV) system. BIPV is a solar power system installed in buildings. Since the BIPV system is installed in buildings, there is a high risk of electric shock and fire accidents. Therefore, in order to improve the safety of BIPV, a protective system is required to block or quickly detect risk factors. In this paper, as a protection system to improve the safety of the BIPV system, it is composed of a rapid shutdown (RSD) that can quickly separate the PV system to prevent fire and electric shock accidents and a system to detect Arc faults that cause PV system fires. RSD and Arc Fault Detector analyzed the operating characteristics according to each condition and confirmed that the safety of the BIPV system can be improved through this.

Fire test procedures for flammability of bulkhead, ceiling and deck finish materials (선박의 격벽, 천정, 내장재 및 표면바닥재의 화재안정성 평가방법)

  • Kim, S.Y.;Kim, D.S.;Ahn, B.H.;No, H.S.
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2007.05a
    • /
    • pp.157-159
    • /
    • 2007
  • It is very important to protect life, property at sea from any fire. Recommendation on improved fire test procedures for surface flammability of bulkhead ceiling and deck finish materials specifies a procedure for measuring fire characterizing their flammability and thus their suitability for use in marine construction. In this paper we investigated the positive expected by fire test procedures for flammability of bulkhead ceiling and deck finish materials. Also, unusual materials were analyzed. Finally, we suggest methods to solve several problems related to unusual materials.

  • PDF

A Study on Factors Affecting Fire Prevention (화재예방에 영향을 미치는 요인에 관한 연구)

  • Chae, Jin
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.100-109
    • /
    • 2020
  • This study aims to empirically verify the factors affecting fire prevention, which is a dependent variable, by establishing a safety culture related to fire prevention, fire prevention education, fire prevention equipment, fire safety knowledge, and fire safety practices as independent variables. The results obtained from the multiple regression analysis were derived as follows in relation to fire prevention. The fire prevention education was found to have the most statistically significant effect on fire prevention, and the fire prevention facility was found to have a statistically significant effect on fire prevention. In addition, fire safety practice was found to have a statistically significant effect on fire prevention.

Evaluation of Evacuation Safety of High School According to Change in the Width of Hallway

  • Seon-Yong Jeong;Hong-Sang Lee;Ha-Sung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.15 no.2
    • /
    • pp.60-72
    • /
    • 2023
  • The purpose of this study is to measure the change in evacuation time at high schools according to the change in hallway width using an evacuation simulation program and to analyze the result of such change. In order to measure the evacuation time according to the change in the hallway width according to the 「Rules on the Standards for Evacuation and Fire Protection Structures of Buildings」 and to analyze the change in evacuation time resulted from the increase in the number of occupants, a scenario was constructed by applying the 「performance-oriented design method and standard for firefighting facilities, etc.」. As a result of the experiment, it was found that the evacuation time was the shortest when the width of the hallway was the widest, which was 3m. On the other hand, the evacuation time took the longest at 1.8m, which was the width of the second narrowest hallway. For the safety of high school students who spend a lot of time at school, it is necessary to secure a wide hallway width when building a new school or to provide periodic safety education in the case of an existing school whose hallways are considered narrow.

A Study on Assesment of Aalidity of Introducing of Design·Construction·Supervision Register Criteria Measures for Hazardous Materials Facilities (위험물시설의 설계·시공·감리업 등록제 도입에 대한 타당성 검토에 관한 연구)

  • Cha, Jung-Min;Lee, Yong-Jae;Kim, In-Beom;Hyun, Seong-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.27-37
    • /
    • 2015
  • This study is to analyze current inadequate status of installing hazardous materials facilities, and to propose rational standards by researching validity for implementing registration for design, construction, supervision for installing fire safety facilities. By studying installation of registering designing, constructing, supervising industry on hazardous material facilities, professional and higher level of stability measures for national hazardous material facility was provided. For above reasons, necessity of institutionalizing of registering standards for construction and supervising industry became clear. Much more gradual institutionalization is needed for construction industry. Moreover, new national qualification should be reconsidered, in order to rebuttal the above and also to cultivate and acquire technical power.

A Study on PBD case of Evacuation in Japan for PBD Approach of Korea. (국내 PBD 기술의 정립을 위한 해외 성능적 피난안전설계사례에 관한 조사)

  • Kim, Dong-Eun;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.322-327
    • /
    • 2008
  • Fire safety provisions have to be determined through Performance -based design in many project. There is a need for quick estimation of evacuation time for scenario analysis in hazard assessment. The key equations on estimating evacuation time have to be known. In Japan There are many experience of PBD according to the Architectural law. It is the aim of this study to investigate the PBD case of Evacuation in Japan for PBD Approach of Korea.

  • PDF

A Study on Prediction of Glass Breakage in Fire of Housing Facilities (주거시설의 화재시 유리파손 예측에 관한 연구)

  • Kim, Bong-Chan;Kim, Dong-Eun;Hwang, Hyun-Bae;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.393-396
    • /
    • 2011
  • 본 연구는 유리내화실험을 실시하고 일본 동경이과대학에서 실시된 유리내화실험과 비교 분석하였으며, 분석결과, 실험에서 유리내화성능은 접합유리, 강화유리, 복층유리, 일반유리 순으로 나타났으며, 유리의 균열이 발생 후 일반유리는 $62^{\circ}C$, 접합유리는 $48^{\circ}C$, 복층유리는 $27^{\circ}C$가 상승한 후 파괴되었다. 일본의 실험에서는 일반유리의 경우 본 실험과 비교 시 비교적 낮은 온도로 측정되었으나 이는 가열조건에 차이에 따른 것으로 판단된다.

  • PDF