• Title/Summary/Keyword: Fire protection safety

Search Result 634, Processing Time 0.024 seconds

Development of Composite Examination Equipment for Improvement of Fire Detectors Checking Technology (감지기의 점검 기술향상을 위한 복합시험기의 개발)

  • Kong, Ha-Sung;Lee, Jong-Hwa
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.135-143
    • /
    • 2008
  • Recently as the testing of fire detector used the testing device for fire detector, there are something the matter in the perception function loss of fire detector, structure and form of the testing device for fire detector. The problem at oxidation of emitting smoke ashes hazardous article part and so on that checking person absorbs be. In this paper the problem or the conventional the examination equipment of fire detectors is analysed and researched. To solve these problems after the theoretical study and design and paint drawing of equipment the prototype of composite examination equipment of fire detectors was made. After compared with the conventional, part that improve of composite examination equipment of fire detectors are verified through the examination. In the future it will be useful the operation state and correct operation time of the fire detectors are measured after the research about the quality of the material and transparency of bellows cover is done.

Introduction of Fire Protection Technology and Its Design Method of Offshore Facilities (해양플랜트의 방화대책 및 설계기술 소개)

  • Koo, Myeong Jun;Choi, Jae Woong;Yoon, Ho Byung
    • Transactions of the KSME C: Technology and Education
    • /
    • v.1 no.1
    • /
    • pp.49-57
    • /
    • 2013
  • The dimensioning accidental loads have been selected through suitable quantitative risk assessment and generally utilized important factors for offshore facility design. The fire hazard can be quantified with dimensioning fire loads. The main purposes of fire protection are to maintain the functionality of safety systems within evacuation period and to prevent the escalation from initial fire to uncontrolled catastrophic fire. This paper introduces the applications and the design methods of active and passive fire protections as representative measures of fire protection of offshore facilities. The passive fire protection requires the high initial installation cost and much difficulty on the operation of facilities and their maintenance. The oil major clients have asked the design contractors of offshore facilities to optimize the amount of passive fire protection with relevant engineering technology recently.

A Study on the Life Risk Assessment of Ship's Engine Room Fire (기관실화재 인명위험성평가에 관한 연구)

  • Han, Sang-Kook;Cho, Dae-Hwan;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.283-289
    • /
    • 2006
  • This study is a preparation for the application of FSA (Formal Safety Assessment) to the fire safety of ships. FSA is the new-fashioned methodology proposed to prevent ships from the accidents. To make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations for the fire safety engineering are investigated. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

Review on the detailed standards for Quantitative Risk Analysis in High Speed Railway Tunnels (고속철도 터널의 정량적 위험도 분석(QRA)을 위한 세부기준에 관한 고찰)

  • Choi, Won-Il;Choi, Jeong-Hwan;Moon, Yeon-Oh;Kim, Seon-Hong;Yoo, Ho-Sik
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.393-407
    • /
    • 2008
  • To protection of fire accident and to minimize danger of spreading the disaster. in railway tunnel, MCT (the Ministry of Construction and Transportation) published "Rules about the Safety Standard of Railroad (2005.10.27)" and "The Detailed Safety Standard of Railroad (2006.9.22)". QRA(Quantitative Risk Analysis) results are applied to establish the fire protection facilities in railway tunnel so that institute the reasonable application about the fire safety facilities However, it is difficult to perform the fire safety design due to lack of the detailed standards about event scenario, fire intensity, incidence rate of accidents etc. Therefore, This paper introduces the practical method about detailed standards of QRA.

A Study on Fire Risk Analysis & Indexing of Buildings (건축물의 화재위험의 분석과 지수화에 관한 연구)

  • Chung, Eui-Soo;Yang, Kwang-Mo;Ha, Jeong-Ho;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.10 no.4
    • /
    • pp.93-104
    • /
    • 2008
  • A successful fire risk assessment is depends on identification of risk, the analytical process of potential risk, on estimation of likelihood and the width and depth of consequence. Take the influence on enterprise into consideration, Fire risk assessment could carry out along the evaluation of the risk importance, the risk level and the risk acceptance. A large part of the limitation of choosing the risk assessment techniques impose restrictions on expense and time. If it is unnecessary high level risk assessment or Probabilistic Risk Assessment of buildings, in compliance with the Relative Ranking Method, Fire risk indexing and assessing is possible. As working-level technique, AHP method is useful with practical technique.

Numerical Investigation on Fire of Stage in Theater: Effects of Natural Smoke Vent Area and Fire Source Location (공연장 무대부 화재에 대한 전산해석 연구: 자연 배연구 면적과 화원 위치 영향)

  • Park, Min Yeong;Lee, Chi Young
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.1
    • /
    • pp.1-11
    • /
    • 2022
  • This numerical study investigates the effects of the size of the natural smoke vent area (10% and 1% of the floor area) and the location of the fire source (i.e., at the side and center of the stage) on the temperature distribution in the compartment and velocity distribution and mass flow rate of flow through a natural smoke vent for a reduced-scale model of a theater stage. Then, the mass flow rate of outflow through the natural smoke vent in the event of a fire for a real-scale theater stage was examined. The case with the larger natural smoke vent area and central fire source location showed lower temperature distributions and higher mass flow rates of outflow and inflow than the case with the smaller natural smoke vent area and side fire source location. The trends of the temperature distributions were closely related to those of the mass flow rates for the outflow and inflow. Additionally, the case with the larger natural smoke vent area and central fire source location exhibited the most non-uniform flow velocity distribution in all cases tested. A bidirectional flow, in which the outflow and inflow occur simultaneously, was observed through the natural smoke vent. In the event of a fire situation in a real-scale theater stage, it was predicted that the case with the larger natural smoke vent area and central fire source location would have a mass flow rate of outflow that is 43.53 times higher than that of the case with the smaller natural smoke vent area and side fire source location. The present results indicate that the natural smoke vent location should be determined by considering the location in a theater stage where a fire can occur.

Simulation analysis for evacuation safety countermeasure in underground facilities (지하공간시설에서의 피난안전대책을 위한 시뮬레이션 해석)

  • Kim, Bong-Chan;Kim, Se-Jong;Kim, Gyeong-Gu;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.100-105
    • /
    • 2011
  • 본 연구에서는 재실자의 밀도가 높은 지하상가는 공간의 특성상 화재가 발생할 경우 다량의 유독가스의 발생 및 연기의 이동경로와 인간의 피난경로 일치로 인하여 피난안전에 큰 위험성이 있다고 사료된다. 이에 지하철 역사와 연결되어 있는 지하상가를 선정 후, 일본 피난안전성평가수법과 FDS(Fire Dynamic Simulator) 및 SIMULEX를 이용하여 비교 분석을 하였으며, 그 결과, 화재발생 후 6분이 경과 시 위험한 것으로 판단되었다. 그에 대한 대책으로 자연 배연구를 설치하여 시뮬레이션 수행을 한 결과 가시도확보 및 각 출구에서의 온도가 하강하는 것을 확인할 수 있었다.

  • PDF

NEW TREND OF FIRE SCIENCE AND EIRE PROTECTION TECHNOLOGY

  • Sugahara, Shinichi
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.19-26
    • /
    • 1997
  • Firesafety design engineerings have been mainly derived from complicated rearrangement of descriptive specifications in codes or regulations through a great number of lessons from fire disasters. In this paper, the author refers to some recent developments in the field of building fire protection. At first, the author expresses his viewpoints concerning performance-based design codes, which have been popular throughout the world as a symbol of freedom from restricted usage of building materials and components prescrived in regulation or bylaws, in spite of some conflicts between objects-oriented design method and industrial mass production. Secondly, the author introduces several innovative fire protection methods adopted for large or void spaces in building complex. Finally, the author forcasts a next development of firesafety science and technology, aimed at securing personal safety in hyperscale urban areas.

  • PDF