• Title/Summary/Keyword: Fire protection Facilities

Search Result 196, Processing Time 0.024 seconds

Review on the detailed standards for Quantitative Risk Analysis in High Speed Railway Tunnels (고속철도 터널의 정량적 위험도 분석(QRA)을 위한 세부기준에 관한 고찰)

  • Choi, Won-Il;Choi, Jeong-Hwan;Moon, Yeon-Oh;Kim, Seon-Hong;Yoo, Ho-Sik
    • Tunnel and Underground Space
    • /
    • v.18 no.6
    • /
    • pp.393-407
    • /
    • 2008
  • To protection of fire accident and to minimize danger of spreading the disaster. in railway tunnel, MCT (the Ministry of Construction and Transportation) published "Rules about the Safety Standard of Railroad (2005.10.27)" and "The Detailed Safety Standard of Railroad (2006.9.22)". QRA(Quantitative Risk Analysis) results are applied to establish the fire protection facilities in railway tunnel so that institute the reasonable application about the fire safety facilities However, it is difficult to perform the fire safety design due to lack of the detailed standards about event scenario, fire intensity, incidence rate of accidents etc. Therefore, This paper introduces the practical method about detailed standards of QRA.

A Study of the Seismic Design Categories about Fire protection Facilities (소방시설의 내진설계범주에 관한 연구)

  • Lee, Jeong-Kyoon;Hur, Man-Sung
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2013.11a
    • /
    • pp.227-228
    • /
    • 2013
  • 소방시설의 경우 지진 시 건축물의 진동 수준에 따라 2차적으로 지진하중을 받는다. 따라서 소방시설에 직접적인 피해를 입히는 수준보다 작은 지진동에 대하여 내진설계를 수행하는 것은 소방시설 설치비용이 증가하게 되어, 합리적인 수준에 대하여 내진설계를 수행할 필요가 있다. 본 연구에는 다양한 소방시설에 대한 실물 내진실험을 실시하였고, 내진설계범주에 따른 내진설계 적용필요성에 대하여 제안하였다. 실험결과 실제 지진 시 내진설계범주 A와 내진설계범주 B에 대한 건축물의 경우 현재의 소방시설로도 내구성을 가질 수 있다고 판단된다. 내진설계범주 C와 D의 경우는 건축물에 설치된 소방시설의 기능보전을 위해 내진보강 설계가 필요하다.

  • PDF

Evacuation Safety Evaluation for Apartment Complexes and Officetel under Floors (공동주택 및 오피스텔 지하층에 대한 피난 안전성 평가)

  • Hyeon-gwon Kang;Yong-Han Jeon
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.67-72
    • /
    • 2023
  • Human and material damage can be reduced if the risk is evaluated by engineering analysis of fire combustion products, smoke concentration, and smoke movement speed in the event of a fire in apartment houses and officetels. In this study, a lot of research on related safety evaluation in the basement needs to be studied and reflected in design, so experimental research was conducted to analyze the flow of smoke through computer simulation and provide analysis data through evacuation safety evaluation. First of all, the five-story underground parking lot subject to simulation has a large floor area, which is advantageous for improving evacuation safety performance, but it uses temperature detectors to increase detection time and fire spread speed. Second, it was analyzed that the evacuation time at all evacuation ports did not exceed the evacuation time, and as the time from the start of evacuation to the evacuation time was 216.9% compared to the travel time, it was evaluated that the safety performance of the evacuation was secured. Third, the above simulation results are a comprehensive safety evaluation based on the non-operation of fire extinguishing facilities in the fire room to increase safety, which means that smoother evacuation safety performance can be secured by linking fire extinguishing facilities.

Simulation analysis for evacuation safety countermeasure in underground facilities (지하공간시설에서의 피난안전대책을 위한 시뮬레이션 해석)

  • Kim, Bong-Chan;Kim, Se-Jong;Kim, Gyeong-Gu;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.04a
    • /
    • pp.100-105
    • /
    • 2011
  • 본 연구에서는 재실자의 밀도가 높은 지하상가는 공간의 특성상 화재가 발생할 경우 다량의 유독가스의 발생 및 연기의 이동경로와 인간의 피난경로 일치로 인하여 피난안전에 큰 위험성이 있다고 사료된다. 이에 지하철 역사와 연결되어 있는 지하상가를 선정 후, 일본 피난안전성평가수법과 FDS(Fire Dynamic Simulator) 및 SIMULEX를 이용하여 비교 분석을 하였으며, 그 결과, 화재발생 후 6분이 경과 시 위험한 것으로 판단되었다. 그에 대한 대책으로 자연 배연구를 설치하여 시뮬레이션 수행을 한 결과 가시도확보 및 각 출구에서의 온도가 하강하는 것을 확인할 수 있었다.

  • PDF

Vital Area Identification of Nuclear Facilities by using PSA (PSA기법을 이용한 원자력시설의 핵심구역 파악)

  • Lee, Yoon-Hwan;Jung, Woo-Sik;Hwang, Mee-Jeong;Yang, Joon-Eon
    • Journal of the Korean Society of Safety
    • /
    • v.24 no.5
    • /
    • pp.63-68
    • /
    • 2009
  • The urgent VAI method development is required since "The Act of Physical Protection and Radiological Emergency that is established in 2003" requires an evaluation of physical threats in nuclear facilities and an establishment of physical protection in Korea. The VAI methodology is developed to (1) make a sabotage model by reusing existing fire/flooding/pipe break PSA models, (2) calculate MCSs and TEPSs, (3) select the most cost-effective TEPS among many TEPSs, (4) determine the compartments in a selected TEPS as vital areas, and (5) provide protection measures to the vital areas. The developed VAI methodology contains four steps, (1) collecting the internal level 1 PSA model and information, (2) developing the fire/flood/pipe rupture model based on level 1 PSA model, (3) integrating the fire/flood/pipe rupture model into the sabotage model by JSTAR, and (4) calculating MCSs and TEPS. The VAT process is performed through the VIPEX that was developed in KAERI. This methodology serves as a guide to develop a sabotage model by using existing internal and external PSA models. When this methodology is used to identify the vital areas, it provides the most cost-effective method to save the VAI and physical protection costs.

The Risk Assessment of the Fire Occurrence According to Urban Facilities in Jinju-si (진주시 도시시설물별 화재발생 위험도 평가)

  • Bae, Gyu Han;Won, Tae Hong;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.24 no.1
    • /
    • pp.43-50
    • /
    • 2016
  • Urbanization in Korea has increased significantly and subsequently, various facilities have been concentrated in urban areas at high speed in accordance with a growing urban population. Accordingly, damages have occurred due to a variety of disasters. In particular, fire damage among the social disasters caused the most severe damage in urban areas along with traffic accidents. 44,432 cases of fire occurred in 2015 in Korea. Due to these accidents, 253 were killed and property damage of 4,50 billion won was generated. However, despite the efforts to reduce a variety of damage, fire danger still remains high. In this regard, this study collected fire data, generated from 2007 to 2014 through the Jinju Fire Department and the National Fire Data System(NFDS) and calculated fire risk by analyzing the clustering of fire cases and facilities in Jinju-si based on the current DB of facilities, offered by the Ministry of Government Administration and Home Affairs. As a result, the risk ratings of fire occurrence were classified as four stages under the standards of the US Society of Fire Protection Engineers(SEPE). Business facilities, entertainment facilities, and automobile facilities were classified as the highest A grade, detached houses, Apartment houses, education facilities, sales facilities, accommodation, set of facilities, medical facilities, industrial facilities, and life service facilities were classified as U grade, and other facilities were classified as EU grade. Finally, hazardous production facilities were classified as BEU grade, the lowest grade. In addition, in the case of setting the standard with loss of life, the highest risk facility was the hazardous production facilities, while in the case of setting the standard with property damage, a set of facilities and industrial facilities showed the highest risk. In this regard, this study is expected to be effectively utilized to establish the fire reduction measures against facilities, distributed in urban space by calculating risk grades regarding the generation frequency, casualties, and property damage, through the classification of fire, occurred in the city, according to the facilities.

A Study on the Legislation for Separate Prime Contracting in the Fire Facility Business (소방시설업의 분리발주 법제화에 관한 연구)

  • Lee, Chang Woo
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.97-103
    • /
    • 2013
  • This study analyzes the present public construction ordering system focussing on the legal framework for the fire facilities construction business and investigates the problem of subcontracting, and further reviews why Separate Prime Contracting should be recommended in policy, social, legislative and regulative terms. This study suggests the amendment of Fire Facilities Construction Business Act, with new bill drafting. The result of this study shows the present public construction ordering system has huge disparities between main building construction business and fire facilities construction business, and recommend Separate Prime Contracting should be adopted in the fields of fire facilities construction business. The system of Separate Prime Contracting may secure business entities' responsibility and higher quality of fire facilities, and also result in reasonable construction practices in reasonable costs. This system may also contribute to improve public safety level in fire facilities construction.

A Study on Prediction of Glass Breakage in Fire of Housing Facilities (주거시설의 화재시 유리파손 예측에 관한 연구)

  • Kim, Bong-Chan;Kim, Dong-Eun;Hwang, Hyun-Bae;Lee, Ju-Hee;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2011.11a
    • /
    • pp.393-396
    • /
    • 2011
  • 본 연구는 유리내화실험을 실시하고 일본 동경이과대학에서 실시된 유리내화실험과 비교 분석하였으며, 분석결과, 실험에서 유리내화성능은 접합유리, 강화유리, 복층유리, 일반유리 순으로 나타났으며, 유리의 균열이 발생 후 일반유리는 $62^{\circ}C$, 접합유리는 $48^{\circ}C$, 복층유리는 $27^{\circ}C$가 상승한 후 파괴되었다. 일본의 실험에서는 일반유리의 경우 본 실험과 비교 시 비교적 낮은 온도로 측정되었으나 이는 가열조건에 차이에 따른 것으로 판단된다.

  • PDF

A Survey on the Performance-based Design Status of Fire-fighting Facilities through the Whole Design Drawings and Specifications (설계도서 전수조사를 통한 소방시설분야 성능위주설계 현황조사)

  • Jeon, Eun-Goo;Bae, Young-Hoon;An, Sung-Ho;Hwang, Cheol-Hong;Hong, Won-Hwa;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.155-162
    • /
    • 2019
  • In Korea, the relevant laws and regulations for fire safety in buildings have been revised. Since 2011, Performance-based Design has been conducted for large-scale or high-rise buildings. However, the Korea's performance-based design is still at a level where life safety evaluation using fire and evacuation simulation tools is compared with existing methods. Although related studies have been conducted continuously for the mandatory performance-based design, the fact that it is relatively unsatisfactory for design and construction of fire-fighting facilities as it mainly focuses on administrative and institutional improvement measures or computer simulation. This study collected 91 performance-based design documents that were carried out nationwide at the initial stage of implementation until 2016 to analyze the status of performance-based design of fire-fighting facilities. As a result, fire-fighting facilities, except for fire extinguish system facilities, were not properly designed for performance. Furthermore, the designers found that if corresponding facilities or higher-level equipment with upgraded performance is additionally installed, the performance-based design fared well compared to the existing the prescriptive-based design.

Measures to Increase Evacuation Safety through Performance-Based Design of Escape Room Cafes (방탈출카페의 성능위주설계에 의한 피난안전성 확대 방안)

  • Hong-Sang Lee;Jai Young Lee;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.4
    • /
    • pp.95-104
    • /
    • 2023
  • The purpose of this study is to propose measures to increase evacuation safety by calculating the habitable time using a fire and evacuation simulation program for the Room-escape cafe currently in operation, and comparing and analyzing it with the evacuation required time. Assuming a fire due to overheating of electric heaters in use in front of the warehouse, the habitable time was calculated through fire simulation, and the occupant's evacuation time calculated through evacuation simulation according installation of safety facilities, etc. was compared and analyzed with the habitable time. In the case of escape room cafes with safety facilities installed, evacuation safety was satisfied, but in escape room cafes without safety facilities, the evacuation safety was not secure. As a result of analyzing evacuation safety for each scenario based on the ASET analyzed in the fire simulation, it was found that in scenario 1, evacuation safety was secured and everyone successfully evacuated, while in scenario 2, no one succeeded in evacuation. These results can be said to confirm that the installation of safety facilities is very important in business establishments such as escape room cafes, which become enclosed structures when games are started.