Integrated Command System for Firefight Satety in Special Disaster Area (특수재난현장 진압대원의 안전을 위한 통합 지휘시스템에 관한 연구)

  • Roh, Tae-Ho
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.98-108
    • /
    • 2015
  • An integrated command system is critical for the safety of firefighters and effective work in the headquarters of a special disaster areas such as natural disaster or large man-made hazard. The integrated command system requires environmental information such as temperature, humidity, and $CO_2$ levels, as well as personal physical information such as pulse and air respirator levels. An Analog to Digital Converter (ADC) chip converts sensed information into digital signals, and a Micro Controller Unit (MCU) transmits the digital signals to a transmission board using serial communication through a Serial Peripheral Interface (SPI). The digital signals are saved in a transmission board and transmitted to the integrated command system by a Radio Frequency (RF) unit. The location of fire-fighters in a building are determined using a gyro sensor and an inertial sensor. The collected information is applied to the integrated command system for firefighter safety and to ensure that they can effectively carry out their duties. Tthis study theoretically and experimentally investigated the technologies of RF transmission, indoor position, and an integrated command system that supports decision making using the transmitted information.

Numerical Analysis of Unsteady Heat Transfer for Location Selection of CPVC Piping (CPVC 배관 동파방지용 열선의 위치 선정을 위한 비정상 열전달 수치해석)

  • Choi, Myoung-Young;Choi, Hyoung-Gwon
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.33-39
    • /
    • 2015
  • In this paper, a numerical experiment was conducted to find out the optimal location of electrical heat trace for anti-freeze of water inside the CPVC pipe for fire protection. The unsteady incompressible Navier-Stokes equations coupled with energy equation were solved. Since the conduction equation of pipe was coupled with the natural convection of water, the analysis of conjugate heat transfer was conducted. A commercial code (ANSYS-FLUENT) based on SIMPLE-type algorithm was used for investigating the unsteady flows and temperature distributions in water region. From the present numerical experiment, it has been found that the vector field of water inside the PVC pipe is opposite to the case of steel because of the huge difference of material properties of the two pipes. Furthermore, it was found that the lowest part of the pipe was an optimal position for electrical heat trace since the minimum water temperature of the case was higher than those of the other cases.

Development of Emergency Exit Guidance Lamps using the Characteristics of Each Sensor in Case of Fire (화재 발생 시 센서별 특성을 이용한 비상구 유도등 개발)

  • Kim, Jong-Kwan;Jeong, Do-Hyeon;Yu, Yong-Woo;Yang, Min-Hyeok;Lee, Boong-Joo
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.16 no.6
    • /
    • pp.1019-1028
    • /
    • 2021
  • Emergency exit guidance lights were designed and manufactured to quickly determine the location of the emergency exit in the event of a fire using a gas sensor, an illumination sensor, a temperature sensor, an Arduino Uno, and a Bluetooth module. This research was designed such that, when a fire breaks out, a red arrow appears as the illuminance value is low and a green arrow as the illuminance value is high to improve visibility when detecting high temperature and smoke. In addition, it is designed to prevent more serious conflagration by applying an alarm sound and text transmission algorithm using a communication module to transmit text messages indicating a 174Hz alarm sound and a fire location to prevent more serious conflagration.

A Discussion on Three Different Issues Between Huangdi Neijing 黃帝內經 and Yixuexinwu 醫學心悟 Regarding the 19 Mechanisms of Disease (病機十九條) (병기(病機)19조(條)에 관하여 ≪의학심오(醫學心悟)≫가 ≪황제내경(黃帝內經)≫과 다른 세 가지 논점(論點)에 관한 고찰(考察))

  • Chan-yong Jeon
    • The Journal of Internal Korean Medicine
    • /
    • v.44 no.6
    • /
    • pp.1271-1278
    • /
    • 2023
  • Objective: The 19 Mechanisms of Disease were first described in Huangdi Neijing. When examining Yixuexinwu, three descriptions that were different from Huangdi Neijing were found. Methods and Results: After examining the two books, three differences in the description of the 19 Mechanisms of Disease were discovered: 1) The upper and lower locations of dyspnea (喘症) are reversed. 2) The ratio of provisions for "fire (火)" and "cold (寒)" is different. 3) The organ affiliation for pain is different. Conclusion: 1) The upper and lower locations of dyspnea (喘症) are reversed. : Regarding external contraction dyspnea (外感喘), Yixuexinwu used the disease of the upper location (lung 上, 肺) in the same way as in Huangdi Neijing. In terms of internal damage (內傷喘), it was separately classified as a disease of the lower location (kidney 下, 腎). 2) The ratio of provisions for "fire (火)" and "cold (寒)" is different. : Arithmetically, if you round off the number after calculating the fraction, the difference between the two ratios becomes the same. Theoretically, five provisions of "fire" are replaced by four provisions of "heat (熱)", and the difference in ratios is exactly the same. Empirically, it emphasizes that there are more illnesses from fire and heat than from cold. 3) The organ affiliation for pain is different. : Huangdi Neijing described general inflammatory pain, while the Yixuexinwu described only stress-related abdominal pain (肝木乘脾 腹痛).

Development of Walk-down Performance Procedures for Fire Modeling of Nuclear Power Plants based on Deterministic Fire Protection Requirements (결정론적 화재방호요건을 기반으로 한 원자력발전소 화재모델링 현장실사 수행절차 개발)

  • Moon, Jongseol;Lee, Jaiho
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.43-52
    • /
    • 2019
  • A walk-down procedure for fire modeling of nuclear power plants, based on deterministic fire protection requirements, was developed. The walk-down procedure includes checking the locations of safety shutdown equipment and cables that are not correctly indicated on drawings and identifying the existence and location of combustibles and ignition sources. In order to verify the performance of the walk-down procedure developed in this study, a sample of important equipment and cables were selected for hypothetical multiple spurious operation (MSO) scenarios. In addition, the hypothetical fire modeling scenarios were derived from the selected safe shutdown equipment and cables and an actual walk-down was conducted. The plant information collected through the walk-down was compared to the information obtained from the drawings, so that the collected information may be used as input values for the fire modeling.

Effect of Platform Screen Door on fire in the subway station (스크린도어가 설치된 지하철 승강장의 화재유동 전산 수치 모사를 이용한 스크린도어의 화재 영향 연구)

  • Jang, Yong-Jun;Jung, Woo-Sung;Park, Won-Hee;Kim, Hag-Beom
    • Proceedings of the KSR Conference
    • /
    • 2007.11a
    • /
    • pp.1337-1345
    • /
    • 2007
  • The present study is a basic investigation for systematically proceeding disaster prevention studying the effect of platform screen door in case of fire at the subway station. In the paper, the characteristics of screen door were surveyed and described. The fully closed platform screen door and the island type of subway station were employed for simulation-study. Numerical simulations of fire driven flow at the subway station with platform screen door were performed with commercial fire CFD code. For analyzing of the effect of platform screen door, the fire simulations with and without the platform screen door were compared. For the fire location, the one is located on the platform and the other case on the railway. The Ultrafast model was taken as fire growth scenario. The maximum heat release rate was 10MW. The propagated time of the heat and smoke to stairs was within 4 minute when the fire is located on the platform. However the heat and smoke propagation was block off by screen door when the fire is located on the railway.

  • PDF

Risk Prediction and Analysis of Building Fires -Based on Property Damage and Occurrence of Fires- (건물별 화재 위험도 예측 및 분석: 재산 피해액과 화재 발생 여부를 바탕으로)

  • Lee, Ina;Oh, Hyung-Rok;Lee, Zoonky
    • The Journal of Bigdata
    • /
    • v.6 no.1
    • /
    • pp.133-144
    • /
    • 2021
  • This paper derives the fire risk of buildings in Seoul through the prediction of property damage and the occurrence of fires. This study differs from prior research in that it utilizes variables that include not only a building's characteristics but also its affiliated administrative area as well as the accessibility of nearby fire-fighting facilities. We use Ensemble Voting techniques to merge different machine learning algorithms to predict property damage and fire occurrence, and to extract feature importance to produce fire risk. Fire risk prediction was made on 300 buildings in Seoul utilizing the established model, and it has been derived that with buildings at Level 1 for fire risks, there were a high number of households occupying the building, and the buildings had many factors that could contribute to increasing the size of the fire, including the lack of nearby fire-fighting facilities as well as the far location of the 119 Safety Center. On the other hand, in the case of Level 5 buildings, the number of buildings and businesses is large, but the 119 Safety Center in charge are located closest to the building, which can properly respond to fire.

Analysis of University Cafeteria Safety Based on Pathfinder Simulation

  • Zechen Zhang;Jaewook Lee;Hasung Kong
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.16 no.2
    • /
    • pp.209-217
    • /
    • 2024
  • Recent years have seen a notable increase in fire incidents in university cafeterias, yet the social attention to these occurrences remains limited. Despite quick responses to these incidents preventing loss of life, the need for large-scale evacuation in such high foot traffic areas can cause significant disruptions, economic losses, and panic among students. The potential for stampedes and unpredictable damage during inadequate evacuations underscores the importance of fire safety and evacuation research in these settings. Previous studies have explored evacuation models in various university environments, emphasizing the influence of environmental conditions, personal characteristics, and behavioral patterns on evacuation efficiency. However, research specifically focusing on university cafeterias is scarce. This paper addresses this gap by employing Pathfinder software to analyze fire spread and evacuation safety in a university cafeteria. Pathfinder, an advanced emergency evacuation assessment system, offers realistic 3D simulations, crucial for intuitive and scientific evacuation analysis. The studied cafeteria, encompassing three floors and various functional areas, often exceeds a capacity of 1500 people, primarily students, during peak times. The study includes constructing a model of the cafeteria in Pathfinder and analyzing evacuation scenarios under different fire outbreak conditions on each floor. The paper sets standard safe evacuation criteria (ASET > RSET) and formulates three distinct evacuation scenarios, considering different fire outbreak locations and initial evacuation times on each floor. The simulation results reveal the impact of the fire's location and the evacuation preparation time on the overall evacuation process, highlighting that fires on higher floors or longer evacuation preparation times tend to reduce overall evacuation time.In conclusion, the study emphasizes a multifaceted approach to improve evacuation safety and efficiency in educational settings. Recommendations include expanding staircase widths, optimizing evacuation routes, conducting regular drills, strengthening command during evacuations, and upgrading emergency facilities. The use of information and communication technology for managing emergencies is also suggested. These measures collectively form a comprehensive framework for ensuring safety in educational institutions during fire emergencies.

Deposition of Inhaled Smoke Particles Produced by Fire (화재에 의한 흡입연기의 호흡기 내 침착에 관한 연구)

  • Goo, Jae-Hark
    • Fire Science and Engineering
    • /
    • v.21 no.2 s.66
    • /
    • pp.64-73
    • /
    • 2007
  • The absorption characteristics of hazardous materials onto human body and defense mechanism differ from each other region within the respiratory tracts, thus adverse health effects of inhaled smokes are associated with not only the concentration but also the location of the particles deposited. In this work, the deposition fraction per surface area and the deposition sites of the smoke particles in human respiratory tracts for each rest and light exercise conditions together with oral and nasal breathing were calculated by using segmental volume tracking method. The results would be used for deriving the amount of absorption of hazardous materials onto human body, thus contribute to the health risk assessments of inhaled fire smokes.

Wild Fire Monitoring System using the Image Matching (영상 접합을 이용한 산불 감시 시스템)

  • Lee, Seung-Hee;Shin, Bum-Joo;Song, Bok-Deuk;An, Sun-Joung;Kim, Jin-Dong;Lee, Hak-Jun
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.6
    • /
    • pp.40-47
    • /
    • 2013
  • In case of wild fire, early detection of wild fire is the most important factor in minimizing the damages. In this paper, we suggest an effective system that detects wild fire using a panoramic image from a single camera with PAN/TILT head. This enables the system to detect the size and the location of the fire in the early stages. After converting RGB image input to color YCrCb image, the differential image is used to detect changes in movement of the smoke to determine the regions which may be prone to forest fire. Histogram analysis of fire flame is used to determine the possibility of fire in the predetermined regions. In addition, image matching and SURF were used to create the panoramic image. There are many advantages in this system. First of all, it is very economical because this system needs only a single camera and a monitor. Second, it shows the live image of wide view through panoramic image. Third, this system can reduce the quantity of saved data by storing panoramic images.