• Title/Summary/Keyword: Fire fighting method

Search Result 95, Processing Time 0.026 seconds

The Seismic Design of Water Extinguishing Piping Systems for Equivalent Static Analysis Method (등가정적해석법에 의한 수계 파이프 시스템의 내진설계)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.100-105
    • /
    • 2012
  • In this study, seismic design in pipeline of pressurized water supply system of water extinguishing system has been carried out. This study described a generation of artificial earthquake wave compatible with seismic design spectrum, and also determined equivalent static loads to analyzed the response spectra acceleration by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented equivalent static analysis method for seismic design of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

The Study of Fire Detector Circuit with Wireless Communication (무선통신기능을 갖는 화재감지기 회로에 대한 연구)

  • Baek, Dong-Hyun;Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • For the development of fire detector equipments that was fused independent type of fire detector and a wireless communication function, this paper adopted a signal processing method of an independent formation fire sensor by a ZigBee communication method, and it was designed that the combinations of fire detector and wireless communications network were enabled. When a fire occurred, output voltage of a fire detector was 0.4 V, the movement pulse width was $600{\mu}s$, and that was confirmed by an experiment. When it has lookout state, LED worked by 30 s cycle and working current is 0.12 mA. When a fire occurred, LED worked by 0.5 s cycle and working current was 7 mA, and through this experiment of power source, Chamber tester, smoke tester,IRED, LED lighting, the propriety of the method that we showed in this paper confirmed.

TUTUM Easy-seismic: Development of a Seismic Design Automation Software for Building Fire Protection Systems (TUTUM Easy-seismic: 소방시설 내진설계 자동화 소프트웨어 개발)

  • Oh, Chang-Soo;Choi, Jun-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.140-148
    • /
    • 2019
  • In line with the "mandatory seismic design of fire protection facilities," development of design automation software is indispensable for improving the reliability and efficiency of seismic design. The seismic design automation software developed in this study is an automated S/W for seismic design of fire-fighting facilities, and functions such as automatic arrangement of anti-shake braces according to Korea National Fire Agency's Seismic Design Standards for fire-fighting facilities, output of seismic bracing calculation bills and automatic quantities counting. In addition, the seismic design automation software not only reduces the work speed by three times compared to the manual design of the designer, but also improves the reliability of the design by reducing the human error related to the design quantity such as the brace. In addition, in the seismic design method of fire protection facilities that have been approached conservatively, it was possible to perform the optimal seismic design by using computer algorithms for at least in the use of braces.

Current Status of Fire Reduction Policy and Its Policy Impressions (화재저감정책의 현황과 개선과제)

  • Jo, Kwang-Hee;Kim, Sung-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.19-25
    • /
    • 2017
  • To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved.

Analysis of the Helicopter Fire Attack Pattern on Forest Fire Behavior (산불진화 헬기의 물 살포유형 분석에 관한 연구)

  • Lee, Si-Young;Bae, Taek-Hoon
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.96-100
    • /
    • 2009
  • Because of dense forests and restriction of approaching for fire fighters, forest fire is easy to be a larger fire in Korea. For this result, the air attack was about 90% of extinguishing, so the application of aircrafts, especially helicopters, will be increased gradually. In the all process of forest fire attack, the method of heli-scattering water was the chief element of success of efficient forest fire attack and safe flight. Therefore, a standardized method of heli-scattering water was required. However, as it was not already standardized, a efficiency and safety of fire fighting have been decreased. In this study, we suggest a 11 patterns of methods for scatterling water based on a actual experience of air attack.

Development of Auto Mixing System of High Expansion Foam for Optimal Expansion Performance according to Changing Temperature (고발포 소화약제의 온도 변화에 따른 최적발포성능 유지를 위한 자동혼합시스템 개발)

  • Kim, Ha-Young;Kim, Sung-Soo;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.139-144
    • /
    • 2010
  • Fire fighting foam is expanded when it mix with many water in mechanical method. It have adaptability, mass production possibility, long-time storage possibility. But foam isn't recommended that it use for extinguish the fire in winter. Because of, expansion ratio is changed according to exterior temperature and environment. In this study, we analysis to effect of expansion according to temperature and develop auto mixing system available for fire engine. As a result of non-standard drug mixture is 3.0% up to 30.08% depending on the temperature of the fire showed that the difference in performance occurs. In addition, analysis of the applicability of automatic mixing system design values and actual experimental data as 0.012% maximum error of the applicability of the system obtained according nataname was judged.

A Study on Economic Evaluations of ESS Load Test Device for Field Load Test in Fire-fighting Emergency Generator Systems (소방용 비상발전기의 현장부하시험을 위한 ESS 부하시험장치의 경제성평가에 관한 연구)

  • Choi, Seung-Kyou
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.9
    • /
    • pp.380-386
    • /
    • 2020
  • The ESS load test device (ELTD) can store and exchange electrical energy during the load test of an emergency generator. On the other hand, it is difficult to commercialize ELTDs based on Li-ion batteries because of the high initial cost, which is higher than a load bank test. If the trade of electrical energy stored in ELTD during the test of an emergency generator is considered, it may be possible to commercialize the ELTD. Therefore, this paper proposes an economic model of ELTD composed of the costs and benefits by considering electrical energy trade to perform accurately economic evaluations of an ELTD. From the simulation results of the economic evaluations of an ELTD and the load bank method, it was found that the commercialization of ELTD is possible when the trade in electrical energy in ELTDs is considered.

Evaluation of the Activation Energy of Chlorinated Poly Vinyl Chloride (CPVC) Using Thermogravimetric Analysis (TGA를 이용한 Chlorinated Poly Vinyl Chloride(CPVC)의 활성화 에너지 평가)

  • Park, Hyung-Ju
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.1-6
    • /
    • 2019
  • The activation energy of CPVC (Chlorinated Poly Vinyl Chloride) used for non-metallic synthetic resin piping in fire-fighting was measured by thermogravimetric analysis (TGA). The activation energy was determined using by TGA kinetic methods, such as Kissinger and Flynn-Wall-Ozawa method. The calculated activation energy was 128.07 kJ/mol (Kissinger method) and 145.60 kJ/mol (Flynn-Wall-Ozawa method). The difference in activation energies calculated by the Kissinger method and Flynn-Wall-Ozawa method was not considered to be significant considering that the different analysis methods. The combustion characteristics will be tested in a future study through an evaluation of thermal deterioration using an accelerated deterioration and air oven aging test and the lifetime of CPVC will be predicted.

Circuit Design of Ultraviolet Flame-Sensor for Fire-Fighting Appliances (자외선 센서를 이용한 화재감지기 응용 회로 설계)

  • Kim, Yeong-Min;Kim, Jong-Man
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we proposed that when combustible burn with ultraviolet radiation, introduce fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame. This research using ultraviolet flame sensor is pyro-electric ultraviolet sensor based black body radiation theory. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV flame detector and proposed method of false alarm reduced to resemble fire. the result proposed the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

A Study on the Improvement Method of the Fire Department Connection for Fire Fighting at the Shopping Center Building (상가건물 소방용 연결송수관설비 송수구의 개선방안에 관한 연구)

  • Lee, Young-Sam
    • Journal of the Korea Safety Management & Science
    • /
    • v.18 no.4
    • /
    • pp.11-17
    • /
    • 2016
  • Currently, the number of a shopping center building is increasing because most people want to go a shopping center building easily for buying many things and eating some foods. That are a normal trend these days. However, the increasing number of shopping center buildings has been increasing the number of shopping center building fires which also have been making social problems. Therefore, this study was conducted for the fire department connection among other fire facilities because it is important for fire suppression. The research subject is on the fire department connections that are on 70 shopping center buildings of more than 5 years old constructed. Survey and analysis were conducted for 70 fire department connections. The result of this study is that all installed fire department connections have a type that includes one or two holes each at 65mm wide, and the average distance between fire department connections and access roads is 4.85m. The total average percentage of insufficiency conditions such as drive ways for fire trucks, visibility, accessibility, pressure range sign, installed height, cover of the hole, etc. is 45.3%. So improvement of law and systems, that are fire facility construction and maintenance implementations, will be needed in my opinion.