• 제목/요약/키워드: Fire facility

검색결과 449건 처리시간 0.02초

A Study on the Current Fire Insurance Subscription and Solutions for Ensuring the Safety of the Traditional Market (전통시장 안전성 확보를 위한 개선방안: 화재보험 가입실태를 중심으로)

  • Kim, Yoo-Oh;Byun, Chung-Gyu;Ryu, Tae-Chang
    • Journal of Distribution Science
    • /
    • 제9권4호
    • /
    • pp.43-50
    • /
    • 2011
  • Concerning the risk factors of the outbreak of a fire in a traditional market, most of those markets are located in downtown areas or residential areas; thus, although their location may be favorable in terms of marketability, they face a potential risk in that a fire may develop into a large blaze owing to poor environment or the absence of facilities prepared for disaster during a fire. Moreover, as many people are densely poised in the markets, it is very probable that a fire may occur owing to the excessive use of heaters in the winter as well as the reckless use of electric and gas facilities. It seems that traditional markets encounter difficulty being insured against fire, because of their vulnerability and that the vast majority of small-scale sellers are likely to suffer mental anguish and tremendous physical injury in case of a fire. However, most of those sellers in the traditional markets are hand-to-mouth sellers, and they lack awareness of safety concerns and have insufficient experience in safe facility management. As small-scale sellers constitute the majority in the traditional market, the subscription rate of fire insurance in most of the traditional markets is low for the reasons of their needy circumstances and their financial burden. Statistically, the subscription by street vendors is non-existent; therefore, these vendors have a fairly limited access to indemnification after fire damage. Because of these problems, this study's purpose is to identify the current level of insurance subscription by these markets, which are exposed to poor facilities and vulnerability to fire. In order to fix this, it appears that shop owners and consumers will have to band together. For this study, we executed a fire policyholder fact-finding mission at traditional markets with approximately 108 and 981 stores. The research method was executed by an investigation using one-on-one individual interviews using a questionnaire. The contents investigated current insurance subscriptions. The method of analysis looked at the difference of insured amount according to volume size through cross-tabulation of the difference of insured amount by possession form, difference of insured amount by market form, difference of insured amount by category of business, difference of insured amount by market size, etc. Furthermore, the study should be used to propose solutions for problems through theoretical review with the use of a literature research, because the field case study was through interviews with the persons concerned, and the survey of the current insurance subscriptions by traditional market shopkeepers. The traditional market would generally have difficulty affording fire insurance. Fire insurance subscription rates of most of the market proved to be inactive, because of the economic burden of payment. Lack of funds is thought to be the main factor that causes a lack of realization about the necessity of fire insurance. In addition to expensive insurance premiums, sometimes, the companies' valuation of the businesses is lower than their actual valuations, and they do not pay out enough during a claim. The research presents an improvement plan that, when presented at the traditional markets, may strengthen their ability to procure fire insurance through the help of the central government. Researchers connected with the traditional market mainly accomplish the initial research. However, although this research has its limitations, it offers considerable benefits. For future researchers, I would suggest looking at several regions for comparison.

  • PDF

The Risk Assessment of the Fire Occurrence According to Urban Facilities in Jinju-si (진주시 도시시설물별 화재발생 위험도 평가)

  • Bae, Gyu Han;Won, Tae Hong;Yoo, Hwan Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • 제24권1호
    • /
    • pp.43-50
    • /
    • 2016
  • Urbanization in Korea has increased significantly and subsequently, various facilities have been concentrated in urban areas at high speed in accordance with a growing urban population. Accordingly, damages have occurred due to a variety of disasters. In particular, fire damage among the social disasters caused the most severe damage in urban areas along with traffic accidents. 44,432 cases of fire occurred in 2015 in Korea. Due to these accidents, 253 were killed and property damage of 4,50 billion won was generated. However, despite the efforts to reduce a variety of damage, fire danger still remains high. In this regard, this study collected fire data, generated from 2007 to 2014 through the Jinju Fire Department and the National Fire Data System(NFDS) and calculated fire risk by analyzing the clustering of fire cases and facilities in Jinju-si based on the current DB of facilities, offered by the Ministry of Government Administration and Home Affairs. As a result, the risk ratings of fire occurrence were classified as four stages under the standards of the US Society of Fire Protection Engineers(SEPE). Business facilities, entertainment facilities, and automobile facilities were classified as the highest A grade, detached houses, Apartment houses, education facilities, sales facilities, accommodation, set of facilities, medical facilities, industrial facilities, and life service facilities were classified as U grade, and other facilities were classified as EU grade. Finally, hazardous production facilities were classified as BEU grade, the lowest grade. In addition, in the case of setting the standard with loss of life, the highest risk facility was the hazardous production facilities, while in the case of setting the standard with property damage, a set of facilities and industrial facilities showed the highest risk. In this regard, this study is expected to be effectively utilized to establish the fire reduction measures against facilities, distributed in urban space by calculating risk grades regarding the generation frequency, casualties, and property damage, through the classification of fire, occurred in the city, according to the facilities.

Monitoring the Reoccurrence of Fire Blight and the Eradication Efficiency of Erwinia amylovora in Burial Sites of Infected Host Plants Using Sentinel Plants (미끼식물을 이용한 화상병 감염 기주 매몰지 내 화상병균 제거 효율 검증 및 병 재발 모니터링)

  • In Woong, Park;Yu-Rim, Song;Nguyen Trung, Vu;Eom-Ji, Oh;In Sun, Hwang;Hyeonheui, Ham;Seong Hwan, Kim;Duck Hwan, Park;Chang-Sik, Oh
    • Research in Plant Disease
    • /
    • 제28권4호
    • /
    • pp.221-230
    • /
    • 2022
  • The fire blight caused by Erwinia amylovora (Ea) was first reported in 2015 in Korea, and the disease has rapidly spread to 22 regions until 2021. In Korea, all host plants in the apple and pear orchards where fire blight occurred should be eliminated and buried by the Plant Protection Act. To prevent the spread of the disease, all burial sites were prohibited from planting the new host plants for the next three years. To confirm the eradication efficiency of Ea and the reoccurrence of fire blight, the surveillance facilities were established on three burial sites from 2019 to 2020 in Anseong-si, Gyeonggi-do, and Chungju-si, Chungcheongbuk-do. As host plants, five apple trees of fire blight-susceptible cultivar 'Fuji', were planted in each facility. All facilities were enclosed with fences and nets and equipped with two CCTVs, motion sensors, and several other sensors for recording weather conditions to monitor the environment of the sentinel plants in real-time. The sentinel plants were checked for the reoccurrence of fire blight routinely. Suspicious plant parts were collected and analyzed for Ea detection by loop-mediated isothermal amplification polymerase chain reaction and conventional polymerase chain reaction. Until November 2022, Ea has not been detected in all sentinel plants. These results might support that the burial control of infected plants in soil works efficiently to remove Ea and support the possibility to shorten the prohibition period of host plant establishment in the burial sites.

Analysis on Chemical Accident Characteristics of Facilities Handling Hydrochloric Acid (염산 취급시설 화학사고 특성분석에 관한 연구)

  • Shin, Chang-Hyun;Lee, Hyun-Seung;Kim, Tae-Hong;Park, Jai Hak
    • Fire Science and Engineering
    • /
    • 제30권6호
    • /
    • pp.14-22
    • /
    • 2016
  • This study analyzed the chemical accidents of hydrochloric acid which is the most frequent chemical in order to make safety management improvement plans. 28 Cases have occurred for the last 4 years, 8 cases of which were casualty accidents, and more efficient plans are needed to minimize the accidents. For this purpose, this study investigated the problems through yearly statistics of the chemical accidents, and suggested appropriate measures of facility management, safety culture and management plans. It is important for businesses to make and implement the improvement measures according to time schedule.

A Study on Revitaliztion of the Emergency Rescue Information System (긴급구조 정보시스템 활성화 방안에 관한 연구)

  • Woo, Seong-Cheon;Chae, Jin
    • Fire Science and Engineering
    • /
    • 제21권2호
    • /
    • pp.1-13
    • /
    • 2007
  • As population has been gravitating to the city and buildings have been getting higher, closer and deeper, the damage is getting greater and taking countermeasures against disaster is rising one of the major government's projects. The aim of this study is to suggest a utilization plan of the emergency rescue information system based on the operating problems after valuating user part, system part and organization part of the system. As result, facility plan for access to emergency rescue information system and operating on user part, raing plan of rapidity and stability on system part, decision making and organization and contribution plan on organization part are suggested.

An Investigation Study on the Coefficient of Occupants Density for Performance Evacuation Capacity Computation in Buildings (성능적 피난용량산정을 위한 대형할인마트의 재실자밀도 계수 조사연구)

  • Seo, Dong-Goo;Shin, Yi-Chul;Lee, Jae-Young;Kwon, Young-Jin
    • Fire Science and Engineering
    • /
    • 제23권5호
    • /
    • pp.1-8
    • /
    • 2009
  • As the rapid and various changing of social aspects, the structures are getting bigger, higher and more complex. The importance of evacuation is on the rise as increased using frequency of multiplex sale facility and it's a high population density. According to the result of a survey with 4 domestic wholesales mart's population density, the maximum was 0.30, 0.46, 0.42, 0.38 人/$m^2$ in and 0.46 人/$m^2$). Considering evacuation dangerousness, the maximum value will be suitable for computation of evacuation capacity and this will be submitted as a basic DATA for computation of evacuation capacity.

A Study on the Characteristics of Interior Finnishing Materials on Restaurant in Multi-use Facillity (다중이용시설로서의 레스토랑 실내건축의 내장재 특성에 관한 연구 - 창원시 상남일반상업지역을 대상으로 -)

  • Kim Dong-Han;Ko In-Seok;Seo You-Seok
    • Korean Institute of Interior Design Journal
    • /
    • 제15권3호
    • /
    • pp.24-32
    • /
    • 2006
  • Through the increasing of social economies and cultural activities, the Food service industry have been growing up steadily in spite of low economic activity. This is owing to increasing income, participation of women in public affairs and a dual-income family, automobile culture, desire for healthful food, shorten working hours, changing of cultural style. Moreover, the recent importance of Interior finishing materials by means of fire in the Restaurant, legal fractional multiple use business establishment are recognized of publicity. Therefore, This Study aim object at probing into the characteristic of Interior finishing material and then analysing the characteristics of space and material according to the typical distribution. In the Interior planning of Restaurant, firstly it is need to probe the Characteristics of interior finishing material at the basic element. This study is going to apprehend the constitution of space and difference of proportion or a point of sameness in the characteristics of material. Moreover, the recent importance of Interior finishing materials by means of fire in the Restaurant, legal fractional multiple use business establishment are recognized of publicity. Throughout probe and analysing, it can append more efficiency and elasticity in the usage of interior finishing material.

Numerical research for Gate Type Waste Incinerators In Environment energy facilities (환경에너지시설내 화격자식 소각로 수치해석 연구)

  • Kim, Jong-Yoon;Jeon, Yong-Han
    • Journal of the Korea Safety Management & Science
    • /
    • 제19권4호
    • /
    • pp.149-155
    • /
    • 2017
  • This study is analyzed combustion phenomena based on the environmental energy facility incinerator. It is assumed that combustible components of waste are composed of carbon and hydrogen, and the combustion process of fuel is by setting as multi-component / multistage reaction. As the combustion chamber is burned, the high temperature environment is achieved, also the heat transfer accompanied by the turbulent flow and the generation of NOx, a pollutant, are interpreted to predict the thermal and fluid characteristics and pollution emissions of the grate incinerator. As the result of internal flow analysis, the slow flow around the ash chute and the mixing effect due to the complicated turbulence around the combustion chamber were predicted to show excellent performance. It is shown to the internal average temperature was about $1024^{\circ}C$, around the about $1000^{\circ}C$ homogeneous temperature distribution. Due to the sudden temperature decrease in the boiler, the flue gas temperature at the outlet was estimated to be about $220^{\circ}C$.

A Study on Facilites Safety of Long-Term Care Facilities for Elderly :Focused on the Factual Survey of Seoul Metropolitan Area (장기요양시설의 노인보호를 위한 시설안전에 관한 연구 : 수도권 시설안전 실태조사를 중심으로)

  • Moon, Yongpil
    • The Journal of the Korea Contents Association
    • /
    • 제20권10호
    • /
    • pp.308-325
    • /
    • 2020
  • This study examines factual facilites safety of long-term care facilities for eldery, for improvement of Korean policy. So, This study reviewed policies of facilites safety of long-term care facilities on main OECD countries. We analyzed factual survey of facilites safety of long-term care facilities in Seoul metropolitan area. The results of the study were as follows: First, There were differences of law and rule of facilites safety of long-term care facilities in comparison with those of social welfare facilities, child day-care center, hospital. Second, it was the result of location condition analysis. Long-term care facilities in the Seoul metropolitan area were located on more than six floors of buildings. The location conditions of private facilities are weak compared to those of corporations and local governments. Third, there were the result of internal structure of facilities. Overall, the placement status was insufficient. For instance, there are smokeproof masks/fireproof blankets, smoke windows(fire safety windows), smoke smothering. In addition, there were places where legal essential installation structures were insufficient. Private facilities were generally insufficient in facility structures compared to those of local governments and welfare corporations. Fourth, there were the result of safety management. It was confirmed that private facilities were insufficient compared to local government facilities. For instance, there are safety management analysis, response manuals, fire preparedness training, etc. Finally, implications and future directions policies of facilites safety of long-term care facilities were discussed based on the finding of the study.

A Computational Study on Cooling Analysis of the Flame Deflector for the 75 tonf Class Propulsion Test Facility (75톤급 추진기관 시험설비 화염유도로 냉각해석에 관한 수치적 연구)

  • Moon, Seong-Mok;Cho, Nam-Kyung;Kim, Seong-Lyong;Jun, Sung-Bok;Lee, Kyoung-Hoon;Kim, Dong-Hwan
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • 제19권2호
    • /
    • pp.55-64
    • /
    • 2015
  • In this study, a 3-D flame cooling analysis is conducted to examine thermal safety for the flame deflector of the 75 tonf class propulsion test facility, and the safe discharge of the exhaust gas is assessed by using numerical results. The Mixture multiphase model is adopted for the simulation of heat transfer and phase exchange process between flame and cooling water, and the computational study using the single species unreacted model for the exhaust plume is carried out for the flame cooling. Numerical analysis predicts maximum temperature on the flame deflector wall for different water flow rates, and evaluates the safe minimum flow rate of water corresponding to the fire-resistant temperature for concrete.