• Title/Summary/Keyword: Fire facility

Search Result 447, Processing Time 0.025 seconds

Development of Digital Twin and Intelligent Monorail Robot for Road Tunnel Smart Management (도로 터널 스마트관리를 위한 디지털 트윈 및 지능형 레일 로봇 개발)

  • Youngwoo Sohn;Jaehong Park;Eung-Ug Kim;Young Sik Joung
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.27 no.1
    • /
    • pp.25-37
    • /
    • 2024
  • The objective of this study was to create intelligent rail robots that are optimized for facility management and implement digital twin systems for smart road tunnel management. An autonomous surveillance system is formed by combining the sensing platform consisting of railing robots, fixed cameras and environmental detection sensors with the digital twin data platform technology for tunnel monitoring and early fire suppression. In order to develop mobile rail robots for fire extinguishing, we also designed and manufactured robots for extinguishing & monitoring and fire extinguishing devices, and then we examined the optimization of all parts. Our next step was to build a digital twin for road tunnel management by developing continuous image display system and implementing 3D modeling. After constructing prototypes, we attempted simulations by configuring abnormal symptom scenarios, such as vehicles fires. This study's proposal proposes high-accuracy risk prediction services that will enable intelligent management of risks in the tunnel with early response at each stage, using the data collected from the intelligent rail robots and digital twin systems.

Fire Protection, Facility Improvement and Protections for FR ESS (FR ESS 의 화재 예방, 설비 개선 및 보호 기술 현장 적용)

  • Lee, Ilyong
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.7 no.1
    • /
    • pp.35-43
    • /
    • 2021
  • 한국전력공사 전력연구원에서는 2018 년 고창 전력시험센터에서 최초 화재 발생 이후, ESS 시스템의 화재 발생 원인에 대한 분석 및 실증시험을 수행하였으며, 이를 통해 현장에서 화재 발생을 최소화할 수 있는 다양한 설비개선안을 도출하였다. 도출된 설비개선안을 통하여 기술지원 요청 부서에서는 전국의 모든 현장 적용을 시행하고 있으며, 이를 통하여 한전이 보유한 모든 ESS 설비는 2021 년 내재 가동될 예정이다.

Impact Assessment of the Damage by a Pool Fire in Yard Storage Facilities of a Container Terminal (컨테이너 터미널 옥외저장소에서의 액면화재에 대한 피해영향 평가)

  • Hwang, Man Woong;Lee, Ik Mo;Hwang, Yong Woo;Chun, Young Woo
    • Journal of Korean Society of Disaster and Security
    • /
    • v.9 no.2
    • /
    • pp.33-42
    • /
    • 2016
  • Domestic harbor yard storage facilities are a place specifically located in a container terminal for import and export of packaged dangerous goods, and due to the recent relaxed criteria for the secured open area, concerns for the extended damage upon accidents are increasing. In this study, the impact of damages by radiant heat was analyzed through a simulation of a pool fire caused by the leakage of flammable liquids from a tank container. As a result, it was analyzed that the distance of radiant heat according to threshold damage levels was beyond the current criteria of the secured open area, and the structural damage of adjacent containers could happen within a very short time if they were exposed to the early pool fire continuously. It is considered that this study will be helpful in preparing the proper criteria for the secured open area between yard storage facilities in a container terminal.

A Study on On-site Discharge Testing for Carbon Dioxide Fire Extinguishing Systems (이산화탄소 소화설비 현장 방출시험 방법론에 관한 고찰)

  • Park, Jun-Hyun;Kang, Tae-Seok;Kim, Jae-Hwan;Kim, Wee-Kyong
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.26-32
    • /
    • 2015
  • Carbon dioxide principally extinguishes fires by smothering, but an acceptable amount of extinguishing agent is needed. To assure the performance of carbon dioxide systems in Korea, computer programs certified by NEMA are being applied in system design. But the design errors can occur because the geometry of a model test facility is not the same as that of the actual fire area. Since the discharge rate tends to vary considerably with the flow pattern in a pipe, an on-site discharge test is necessary to ensure the performance of the system, especially with low pressure carbon dioxide. Technical standards for carbon dioxide systems do not give detailed guidelines for discharge tests at present. Based on comparative analysis of standards and practical tests, this paper suggests a methodology for on-site discharge tests.

Evacuation Simulation to Assess Human Safety of Social Welfare Facility (사회복지시설의 인명안전도 평가를 위한 탈출 시뮬레이션)

  • Kim, Hyun-Seok;Kim, Kook-Hyun;Kim, Nam-Sook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.1
    • /
    • pp.138-143
    • /
    • 2011
  • Growing attention of a society to protecting weak people leads an increase of various social welfare facilities. Therefore, safety of the occupants at emergency situations, such as fire, must be considered as an important factor during the design and operation of those facilities. In this paper an exploratory study is carried out on a method quantitatively assessing the human evacuation safety of social welfare facilities. A evacuation simulation method, being routinely used in the evacuation analysis of passenger ships deriving 'Evacuability' as a quantity of safety, is applied to assess the human safety of a facility for single-moms. Based on the simulation results, the main factors that must be considered while carrying out the evacuation simulation for the human safety assessment of the facility are investigated.

Dependence of Explosion Overpressure of Flammable Gas on the Change of Volume Blockage Ratio of Facilities (설비 혼잡도에 따른 가연성 증기운의 폭발과압의 변화)

  • Lee, Seung Kuk;Lee, Da Eun;Kim, Sung Chan;Yoon, Kee Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.54-61
    • /
    • 2015
  • A series of CFD calculation has been conducted to investigate the effect of facility confinement on explosion power for process plant facility. The level of confinement of a facility was simplified with VBR(volume blockage ratio) and averaged size of obstacles. FLACS which is 3D CFD code of gas dispersion and the explosion was used for simulating the explosion phenomena in the idealized domain with different confinement level. The CFD results showed a tendency that the overpressure increases with increasing VBR and number of obstacles. The effect of VBR on the overpressure was relatively small for the case of number of obstacle less than 25. The results of this study can be used to provide a safety guideline considering the facility confinement in case of leakage accident of flammable gas and vapor in process plants.

Problems and Improvement Directions of Fire Protection Designing and Supervising Jobs (소방 설계·감리업의 문제점 및 개선방향에 관한 연구)

  • Cha, Jong-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.12
    • /
    • pp.8745-8752
    • /
    • 2015
  • Since many accidents have occurred in Korea in these days, many people have lost their health and have been damaged. The damages caused by fires which occur to many buildings where many people always reside takes a substantial share of the total damages. And since the proportions of the domestic fire protection designing/supervising industries are relatively much disregarded compared to other kinds of work, it is in the situation that there are many cases of serious damages because the fire protection equipment didn't exert the proper functions on fire after a building is constructed since the supervision against the poor construction along with the inadequate design. In order to improve such situations, in case of the design industry, the criteria on registration and workforce placement, the scope of operation, the design documents required when requesting the agreement to the construction permits, the responsibilities and authorities about the jobs of the fire protection facility designers must be improved and, in case of supervising industry, the registration criteria, the operation scope and the kinds, methods, targets and criteria of supervision, the criteria on the additional placement of assistant supervisors, the contents and scope of work must be improved, the PQ system and Public Supervision System must be reviewed and the systems for preventing any poor supervision must be improved in order to pursue the security of the people and their properties at the same level as the other kinds of work by preparing for the firm position and foundation of the fire protection design and supervision.

A Study on Fire Spread and Evacuation Risk of Conduit Combustion in Ceiling Hiding Place (천장 은폐장소 전선관 연소에 따른 화재확산 및 피난 위험도에 관한 연구)

  • Park, Kwang-Muk;Jeon, Jae-Kam;Bang, Sun-Bae
    • Fire Science and Engineering
    • /
    • v.34 no.1
    • /
    • pp.55-65
    • /
    • 2020
  • In this study, the ISO 5660 and ISO 5659 combustion tests were conducted with synthetic resin conduits (CD, VE) and metal conduit (ST) used for wiring work in electrical facilities, which can be installed in ceiling concealed places. Then, fire spreading and evacuation risks were analyzed based on the measured data. In the ISO 5660 test, CD of 120.5 MJ/㎡, VE of 81.9 MJ/㎡, and ST of 4.9 MJ/㎡ were measured. In the ISO 5659 test, the CD 1320, VE 731, and ST 102 were measured, and then the maximum smoke densities were measured for CD 605 s, VE 740 s, and ST 1,200 s. In terms of fire spreading and evacuation risk, the CD conduit, VE conduit, and ST conduit were in order. In the fire spreading risk analysis, total heat emission was calculated as 4,820 MJ/㎡, 4,267 MJ/㎡, and 196 MJ/㎡ for CD, VE, and ST, respectively. Evacuation risk analysis shows at transmittance of 89%, CD is 127 s, VE is 35 s, and ST is 969 s. At transmittance of 79%, representing almost invisible concentration, CD is 157 s and VE is 50 s. The CD and VE conduits had a high fire spreading and evacuation risks, while the ST conduit had little effect on fire spreading and evacuation risk.

Analysis of the Evacuation Safety in a Fire at Welfare Center for Disabled (장애인복지관 화재 시 피난안전성 분석)

  • Park, Sunah;Lee, Jai Young
    • Journal of the Korea Convergence Society
    • /
    • v.12 no.12
    • /
    • pp.315-322
    • /
    • 2021
  • This study analyzes the Required Safe Egress Time (RSET), in the event of a fire at a welfare center for the disabled, using the emergency passage according to the floor arrangement of users to evaluate the safety and the difference in RSET for each emergency passage using the Pathfinder simulation program to suggest an efficient evacuation method. As a result of RSET, it was found that there is no problem in evacuation safety for the current state of the facility's personnel allocation by satisfying the standard RSET in case of fire, and evacuation can be completed safely by evacuating through stairs rather than using elevators if possible. It is necessary for employees to be provided sufficient education and training in advance so that they can evacuate effectively with the disabled in case of fire. This study gives significance in saving many precious lives and safely evacuate in case of fire as evacuation routes were secured through the design, construction and operation of facilities for the disabled and the RSET was shortened through regular evacuation practices. It is necessary to discuss the further RSET studies based on the automatic fire shutters open or not when a fire occurs at a specific location following the installation of automatic fire shutter at the entrance of each floor of the facilities.