• Title/Summary/Keyword: Fire facilities

Search Result 835, Processing Time 0.032 seconds

A Study on the Construction Methods of Sealer of Injection Type for Leakage Maintenance for Water Leakage and Cracks in Concrete (콘크리트 누수균열의 유지관리를 위한 누수보수용 주입형 실링재 시공방법 연구)

  • Kwon Shi-Won;Oh Mi-Hyun;Kwak Kyu-Sung;Oh Sang-Keun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.6 no.1 s.19
    • /
    • pp.87-91
    • /
    • 2006
  • Since water leakage and cracks are not the source of serious problems such as long-term lowering of performance and durability of a stricture, including damages to operating facilities of a structure, damages to internal finishing materials, exhibition, and goods, and pollution of residential environment, they might have led to development of positive coping skills; however, an instant loss of lives or property due to earthquake, explosion, typhoon, or a fire was indeed neglected. In these days, repair materials for leakage cannot help but being taken in temporary way without any noticeable countermeasure. This kind of repair is socially criticized many times that is defective construction even if this costs a lot. It was not arrange the standard for construction methods of sealer of injection type for leakage maintenance, even it has been used various type of construction methods for leakage part. In conclusion, we suggest that the construction methods of sealer of injection type for leakage maintenance for leakage to establish the leakage repairing technology as increase of structure demand. Therefore, it would be possible to provide a stage-by-stage solution by developing systematic research activities among the industry, schools, and research institutes to spread maintenance management techniques globally through technical solution to water leakage and cracks, acquisition of structural safety with prolonged durability for life cycle, reduction of water leakage repair expense s, and so on.

A Study on the Analysis of Hazardous Risk Factors for Component in Hydrogen Station with Water Electrolysis Device (수전해 수소충전소 부품별 유해위험요인 분석)

  • Seo, Doo-Hyoun;Rhie, Kwang-Won;Kim, Tae-Hun
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.33-38
    • /
    • 2019
  • In order to invigoration the hydrogen economy, production of hydrogen needed for hydrogen charging stations and hydrogen fuel cells is needed. Generally, it is reforming used to coal fuel or natural gas. Other technologies include water electrolysis using pure water. Among these water electrolysis technologies, development is mainly carried out using PEM(Polymer Electrolyte Membrane electrolysis). In this study, the company aims to identify potential harmful hazards to PEM electrolysis hydrogen stations in the development stage among hydrogen charging stations. In order to find the hazardous factors in the facilities of the electrolysis and hydrogen charging stations, we were analyzed by Failure Mode & Effect Analysis(FMEA).

A Study on the Analysis of Human-errors in Major Chemical Accidents in Korea (국내 화학사고의 휴먼에러 기반 분석에 관한 연구)

  • Park, Jungchul;Baek, Jong-Bae;Lee, Jun-won;Lee, Jin-woo;Yang, Seung-hyuk
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.66-72
    • /
    • 2018
  • This study analyses the types, related operations, facilities, and causes of chemical accidents in Korea based on the RISCAD classification taxonomy. In addition, human error analysis was carried out employing different human error classification criteria. Explosion and fire were major accident types, and nearly half of the accidents occurred during maintenance operation. In terms of related facility, storage devices and separators were the two most frequently involved ones. Results of the human error-based analysis showed that latent human errors in management level are involved in many accidents as well as active errors in the field level. Action errors related to unsafe behavior leads to accidents more often compared with the checking behavior. In particular, actions missed and inappropriate actions were major problems among the unsafe behaviors, which implicates that the compliance with the work procedure should be emphasized through education/training for the workers and the establishment of safety culture. According to the analysis of the causes of the human error, the frequency of skill-based mistakes leading to accidents were significantly lower than that of rule-based and knowledge based mistakes. However, there was limitation in the analysis of the root causes due to limited information in the accident investigation report. To solve this, it is suggested to adopt advanced accident investigation system including the establishment of independent organization and improvement in regulation.

Development of Wireless Base Station Remote Monitoring System Using IoT Based on Cloud Server (클라우드 서버 기반 IoT를 이용한 무선기지국 원격 감시시스템 개발)

  • Lee, Yang-weon;Kim, Chul-won
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.6
    • /
    • pp.849-854
    • /
    • 2018
  • Radio base stations, which are widely distributed across large areas, have many difficulties in managing them. Unmanned radio base stations in remote mountains are having a hard time accessing them in case of emergencies. Major telephone service providers only remotely control incoming and outgoing information and local small business partners responsible for maintaining actual facilities do not possess such technologies, so they are each checked during field visits. In this study, in order to process the sensor raw data and smoothing, we apply the particle filters and confirmed that the performance of sensor data accuracy is increased. Integrated system using temperature, humidity, fire condition, and power operation at a wide range of radio base stations under the real-time monitoring status is operated well. It show that all of the status of base station are monitored at the remote office using the cloud server through internet networking.

Uncontrolled Landfill Maintenance Plans through the Environmental Evaluation (환경성평가를 통한 비위생 매립지 정비방안)

  • Lee, Hae-Seung
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.3
    • /
    • pp.59-71
    • /
    • 2008
  • In this study, we intend to present the uncontrolled landfill maintenance plans by diversely reviewing the operating conditions of landfill and environmental effects and economical issues resulted from the operation of landfill for the purpose of suggesting the optimal maintenance plans applicable to the uncontrolled landfill and unused landfill located in Korea. We perform the basic and precise surveys against three landfill sites showing the biggest problem out of 8 unsanitary landfills sites located in Y County. We compare and review the treatment plans prepared and operated by the N Landfill. The compared and reviewed results show that the local stabilization plan is more effective than the excavation and transfer treatment plan when considering the economic efficiency only. However, the excavation and transfer treatment plan is valid when considering the diverse elements. The G Landfill is operated with separated into living waste landfill section and construction waste landfill section. However, some landfill gas collection bores or holes are installed in its living waste landfill section, which has not been used for about 20 years, as a part of follow-up control. The element causing the environmental damage is considerably reduced in its living waste landfill section. However, the effort to keep the follow-up control through the local stabilization work is required. The landfill is under processing in the construction waste landfill section. However, most of buried wastes are the inorganic wastes such as waste materials and concrete, so the maintenance plan focused on the use of top land by installing the local stabilization facilities is considered as an effective plan. The landfill is under processing in the K Landfill. It seems to be difficult to maintain this landfill through the local stabilization. The excavation and transfer treatment plan to completely remove the potential environmental pollution source is considered as the valid plan.

A Study on the Conservation of Library Materials (도서관자료(圖書館資料) 보존(保存)에 관한 연구(硏究))

  • Kweon, Kie-Won
    • Journal of the Korean BIBLIA Society for library and Information Science
    • /
    • v.6 no.1
    • /
    • pp.179-213
    • /
    • 1984
  • The history of recording and conserving for maintenance the human's memory from ancient times to modern's has brought about a lot of changing process of the recorded information media with developing in culture, and each society has made important recorded materials in his library as essentially the social apparatus. But most of them that were damaged by factors of the natural disaster, humidity, temperature, light, fungi and insects in the library, and were resulted in deterioration and losing the numerous materials. For removing the inevitable phases repeated, there are studying for counterplan of the fundamental environment factors about preservation, restoration and chemical research of materials in advanced countries, but I get a few researches about protecting the cultural properties. Therefore I research the survey of the actual conditions on 72 university libraries centering around them, and then I have researched the collection rate 81 percent, 58 university libraries. (local : 35, in seoul : 23) As the result of this research, I propose the model of the environment factors of conserving the library materials. 1) To apply the equipment of processing the radiant energy to the new construction and buildings. 2) To remove factors that occur fungi and insects by facilities being controlled relative humility, temperature, and to equip the ventilation arrangement in the library. 3) To shelve all acquired and bound materials after proceeding the vacuum fumigator. 4) Those who want to enter into the library stack were surely taken in sterilzing their hands and shoes, and must put on the gown. 5) To use the vacuum dusting thing (machine) for removing the dust without spreading out the floor of the library at any time. 6) To set up the gas automatic fire extinguisher worked by smoke sensor. 7) To assist the research into the preservation, natures and environment of recorded materials, and to supply financial funds for librarian. 8) To hold regularly the workshop be able to educate the methods of preservation materials by the constant system. (Library Association) 9) To add to responsibilities on certification of preservation materials for librarian. 10) To hold the constant committee system in each library. 11) To keep up with the ideal environment (humidity, temperature, light, ventilation, etc.) of preservation materials in the arrangement room, and to put on the gown.

  • PDF

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.

Pool proof safety through the old apartments redesigned to ensure safety study (노후아파트 안전관리를 통한 풀 푸르프 재설계로 안전성 확보에 관한 연구)

  • Baek, Dong Seung;Lee, Jong Hyun;Park, Sung Bong
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.3
    • /
    • pp.280-287
    • /
    • 2018
  • Purpose: The study is based on comparative review of the actual inspection of apartments and aims at proposing easy accessible and useful safety control which is enhanced from pre-existing safety apparatus. Method: On the basis of preceding research data of apartment buildings, the study presents reported problems and real condition of apartment buildings based on Housing Related Legislation and Housing Act. Results: Safety management plans and safety inspection for buildings are needed. When conducting a safety check, traceability management system for internal/exterior facilities should be available. Most important of all, 24 hour a day of self-management system for elevators, fire protection, and security cameras is necessary. Conclusion: Through the study, there should be a process of confirming problems of building security management; such as checking the management condition through apartments' resident representatives, and seeking improvement measures.

Some Considerations on the Capacity Estimation of Emergency Electric Generator in Apartment Complex (공동주택의 비상발전기 용량산정방식에 관한 고찰)

  • Kim, Jeong-Tae;Rhee, Wook
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.10 no.4
    • /
    • pp.68-77
    • /
    • 1996
  • In this study, for the capacity estimation of emergency electric generators built in apartment complex using NEGA C 201 method, it was proposed application methods of simultaneously starting groups and demand factors. Also, it was suggested that capacities of the electric generator might be calculated for two kinds of electric facilities; one is loads for the convenience of tenants when main electric supply cuts off, and the other is loads for fire. For 7 apartment complex of large-size (about 1, 500 households), medium- size (about 1, 000 households) and small - size (about 500 households), electric generator capacities were calculated and electric power were measured. Through the comparison between calculated values and measured values, it could be proved the suitability of these application methods. In addition, the calculated electric generator capacities were appeared to fit into engin capacities by NEGA C 201 method as well as those by conventional method.

  • PDF

Dependence of Explosion Overpressure of Flammable Gas on the Change of Volume Blockage Ratio of Facilities (설비 혼잡도에 따른 가연성 증기운의 폭발과압의 변화)

  • Lee, Seung Kuk;Lee, Da Eun;Kim, Sung Chan;Yoon, Kee Bong
    • Journal of the Korean Institute of Gas
    • /
    • v.19 no.6
    • /
    • pp.54-61
    • /
    • 2015
  • A series of CFD calculation has been conducted to investigate the effect of facility confinement on explosion power for process plant facility. The level of confinement of a facility was simplified with VBR(volume blockage ratio) and averaged size of obstacles. FLACS which is 3D CFD code of gas dispersion and the explosion was used for simulating the explosion phenomena in the idealized domain with different confinement level. The CFD results showed a tendency that the overpressure increases with increasing VBR and number of obstacles. The effect of VBR on the overpressure was relatively small for the case of number of obstacle less than 25. The results of this study can be used to provide a safety guideline considering the facility confinement in case of leakage accident of flammable gas and vapor in process plants.