• Title/Summary/Keyword: Fire facilities

Search Result 842, Processing Time 0.024 seconds

Research on the Cognition and Education of Safety for Children (아동의 안전에 관한 인식과 교육 실태 조사 연구)

  • 이한용;우종웅;김일영
    • Korean Journal of Health Education and Promotion
    • /
    • v.18 no.3
    • /
    • pp.59-75
    • /
    • 2001
  • It is necessary to examine from primary school children's viewpoint to perception of safety as to how they cope with a condition threatening safety at the realistic world with risky environment and whether knowledge obtained through education is transmitted to action in a correct way. For this, this study explored and analyzed children's perspective to safety felt in life, their achievement of education to safety as trainees, and their perception extent to safety. As a result of it, following conclusion could be obtained. First, as for safety on their way to school and home, the lower grade they were, the more they felt safe, but the higher they were, the more they felt uneasy, which was examined that they generally had uncomfortable mind. Second, as for whether safety education was performed or not, it was indicated that safety education was generally executed, but lower graders responded that safety education was executed, but high graders responded that it was not executed. Third, as for observance of traffic rules, it was examined lower graders kept them well, but higher graders did not do so. Fourth, as for safety of play, it was indicated lower graders wore protective equipment by parents' concern, but higher graders did not wear them since they were full of confidence counting on their capability. Fifth, as for life safety, it was indicated the area most preferentially educated from parents' viewpoint was traffic safety, and the next ones were gas and fire safety. Sixth, as for fire safety, it was indicated they did not play with fire, but higher graders compared to lower ones, played with fire as the means of curiosity and play. Thus, curricula for children's safety education executed from adults' viewpoint should be established, and assessment of children's safety education should get out of the limitation of execution of safety education to habituated action by the transmission of children's knowledge. Also it is urgent to develop programs with which to perform children;'s education at the level of children, establish and operate safety education facilities for practice education that teachers and children can receive safety education through experience by building up children's safety education related entities. And it is thought that safety should not left to only children, but their safety would be kept by developing and training safety education programs to all organizations and individuals related to safety.

  • PDF

A study on the Optimum Capacity of Citadel (선원대피처의 적정규모에 관한 연구)

  • Kim, Won-Ouk;Chae, Yang-Bum;Kim, Chang-Jae
    • Journal of Navigation and Port Research
    • /
    • v.36 no.1
    • /
    • pp.21-26
    • /
    • 2012
  • Recently, vessel hijacking by pirates has been a big issue around the world. For example, the hostages of VLCC "SAMHO Dream" were released for a large sum of ransom. On January 20, 2011 "SAMHO Jewelry" succeeded releasing all of the 21 crews on the vessel by attacking the pirates in international waters for the first time since the founding of the Naval Force. Furthermore, the "HANJIN Tianjin" crews evacuated to the Citadel promptly and were rescued by the navy. As hijacking of Korean vessels by pirates is increasing, various safety measures must be implemented. As a matter of fact, the standard for ship's facilities has been partially revised and setting up an evacuation shelter on all vessels sailing dangerous zone has been reinforced. This research aims to discuss crew Citadel installation on vessels intended for long haul. In addition, it will look at measures against potential gas flow in the event of pirate armed attacks and fire outbreak onboard a vessel. It will also assess the optimal number of crew Citadels theoretically. Lastly, the optimal number of shelters in the event of fire outbreak will be discussed based on an FDS simulation.

A Study for Deducing the Problems and Improvements of Health Safety and Welfare Policy for Korean Firefighters by Delphi (델파이 기법을 통한 소방공무원 보건안전정책의 문제점 및 개선방안 도출)

  • Park, Chanseok
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.1
    • /
    • pp.34-43
    • /
    • 2020
  • Purpose: In this study, we will try to find out problems and improvements of the policies in order to verify whether the plans contribute to the health and welfare of the firefighters properly. Method: By the Delphi analysis by experts. Result: There are problems such as absence of Firefighters' hospital, insufficient mental health education program in fire department, lack of on-site risk assessment system, problem on ineffectiveness of mental and physical health care business, lack of substantiality on mental and physical stability program, absence of mental health education, ensuring the confidentiality for users of mental health programs, lack of support for parent firefighters, lack of firefighters' retirement design and insufficient treatment for female firefighters. Conclusion: There are Improvements such as establishing Firefighters' hospital, improving mental health education and training CISD leaders in the fire department, preparing disaster risk assessment system, effectiveness measurement for visiting psychological counseling projects, improving the program through customer satisfaction surveys, establishment of mental health education system, ensuring confidentiality by improving personnel systems, encourage childcare leave and introduce childcare facilities at fire stations, revitalizing retirement Firefighters and policy development for female firefighters.

A study on the Improvement Method of the Report and Reward System on an Illegal Behavior of the Emergency Exit (비상구 불법행위 신고포상제도의 개선방안에 관한 연구)

  • Kim, Myeong Sik;Lee, Tae Shik;Cho, Won Cheol
    • Journal of Korean Society of Disaster and Security
    • /
    • v.5 no.2
    • /
    • pp.49-59
    • /
    • 2012
  • The safety management of the emergency exit, by directly related to the $civil^{\circ}$Øs dead in the fire situation, have limited by which the fire station take the on-side and control-centered way of business processing, it is expect to the effects in which the citizen have to concern and to take part. From 2010 years in the back-ground, it is operated nationally the report and reward system on an illegal behavior of the emergency exit, it is happened to the unfit operating situation in the mission and direction of the system up which the exit paparazzi act with intent to receive the reward payments. The study suggests solution through analyzing the illegal emergency exit operation result of sixteen counties and the Seoul metropolitan from year 2010 to 2011. Firstly, the report destination is adjusted to the multiple use establishments and the large-scale multiple use facilities over the limit level is limited under five times the report events of the same people in the minor endorsement. And the fine incomes should be invested to the disaster prevention acting related with the exit. Secondly, for upgrade of the report accuracy, a reporter is received the possible information for the confirmation of an illegal act, has become to lead the pre-monitoring act which the reporter is can to take the safety education and to guide the information about season and vulnerable business location. Finally, considering the support way about the encounter facility, the fire officer is not happen to occur the repetitive report in the same place, is related to the volunteer service system the report acts, consider as the volunteer service time, and must support them to act as the disaster prevention volunteer.

Mapping Burned Forests Using a k-Nearest Neighbors Classifier in Complex Land Cover (k-Nearest Neighbors 분류기를 이용한 복합 지표 산불피해 영역 탐지)

  • Lee, Hanna ;Yun, Konghyun;Kim, Gihong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.43 no.6
    • /
    • pp.883-896
    • /
    • 2023
  • As human activities in Korea are spread throughout the mountains, forest fires often affect residential areas, infrastructure, and other facilities. Hence, it is necessary to detect fire-damaged areas quickly to enable support and recovery. Remote sensing is the most efficient tool for this purpose. Fire damage detection experiments were conducted on the east coast of Korea. Because this area comprises a mixture of forest and artificial land cover, data with low resolution are not suitable. We used Sentinel-2 multispectral instrument (MSI) data, which provide adequate temporal and spatial resolution, and the k-nearest neighbor (kNN) algorithm in this study. Six bands of Sentinel-2 MSI and two indices of normalized difference vegetation index (NDVI) and normalized burn ratio (NBR) were used as features for kNN classification. The kNN classifier was trained using 2,000 randomly selected samples in the fire-damaged and undamaged areas. Outliers were removed and a forest type map was used to improve classification performance. Numerous experiments for various neighbors for kNN and feature combinations have been conducted using bi-temporal and uni-temporal approaches. The bi-temporal classification performed better than the uni-temporal classification. However, the uni-temporal classification was able to detect severely damaged areas.

Installation Standards of Urban Deep Road Tunnel Fire Safety Facilities (도심부 대심도 터널의 방재시설 설치 기준에 관한 연구(부산 승학터널 사례를 중심으로))

  • Lee, Soobeom;Kim, JeongHyun;Kim, Jungsik;Kim, Dohoon;Lim, Joonbum
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.727-736
    • /
    • 2021
  • Road tunnel lengths are increasing. Some 1,300 tunnels with 1,102 km in length had been increased till 2019 from 2010. There are 64 tunnels over 3,000 m in length, with their total length adding up to 276.7 km. Safety facilities in the event of a tunnel fire are critical so as to prevent large-scale casualties. Standards for installing disaster prevention facilities are being proposed based on the guidelines of the Ministry of Land, Infrastructure and Transport, but they may be limited to deep underground tunnels. This study was undertaken to provide guidelines for the spacing of evacuation connection passages and the widths of evacuation connection doors. Evacuation with various spacing and widths was simulated in regards to evacuation time, which is the measure of safety, using the evacuation analysis simulation software EXODUS Ver.6.3 and the fire/smoke analysis software SMARTFIRE Ver.4.1. Evacuation connection gates with widths of 0.9 m and 1.2 m, and spacings of 150 m to 250 m, were set to every 20 m. In addition, longitudinal slopes of 6 % and 0 % were considered. It was determined to be safe when the evacuation completion time was shorter than the delay diffusion time. According to the simulation results, all occupants could complete evacuation before smoke spread regardless of the width of the evacuation connection door when the longitudinal slope was 6 % and the interval of evacuation connection passage was 150 m. When the evacuation connection passage spacing was 200 m and the evacuation connection gate width was 1.2 m, all occupants could evacuate when the longitudinal slope was 0 %. Due to difference in evacuation speed according to the longitudinal slope, the evacuation time with a 6 % slope was 114 seconds shorter (with the 190 m connection passage) than with a 0 % slope. A shorter spacing of evacuation connection passages may reduce the evacuation time, but this is difficult to implement in practice because of economic and structural limitations. If the width of the evacuation junction is 1.2 m, occupants could evacuate faster than with a 0.9 m width. When the width of a connection door is 1.2 m with appropriate connection passage spacing, it might provide a means to increase economic efficiency and resolve structural limitations while securing evacuation safety.

Economic and Evacuation Time Analysis of Horizontally-installed Indoor Emergency Exit (하향식 피난구의 경제성 및 피난 소요시간 분석)

  • Liu, Yue;Kim, Sun-Kuk;Kim, Ki-Hyuk;Lee, Dong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.18 no.4
    • /
    • pp.363-373
    • /
    • 2018
  • Evacuation facilities are installed so that people can evacuate high-rise apartment houses when it is impossible to escape fire through the front door. The households of apartment houses may escape the building in two ways, which will reduce loss of lives. This study examined the characteristics of two-way evacuation facilities, including a light-weight partition wall, shelter space at the balcony and horizontally-installed indoor emergency exit. Then, it proposed a horizontally-installed outdoor emergency exit that improved the problems of the examined facility types, and analyzed its economic-feasibility. When a horizontally-installed emergency exit instead of a traditional type to escape from fire is used, people may be more autonomous in deciding whether active evacuation is possible or not. Thus, the time required to evacuate the building with 4 different evacuation methods using the stairs and horizontally-installed emergency exit was simulated in consideration of the impact of evacuation methods that people choose on the time required for evacuation using pathfinder. Then, the simulation results were compared and analyzed. Any appropriate evacuation method to reduce the time required for evacuation was predicted, analyzed and decided. As a result of this study, it was analyzed that the high - rise apartment top - down type evacuation zone can shorten the total evacuation time compared to the staircase type.

Temporal and Spatial Distributions of Emergency Medical Services: Busan (부산시 응급의료서비스의 시공간적 분포특성)

  • Nam, Kwang-Woo;Kim, Jeong-Geon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.10 no.1
    • /
    • pp.113-123
    • /
    • 2007
  • This study analyzed the appropriateness of the spatial distribution of fire stations and emergency medical facilities, the main providers of emergency medical care, in Busan. The area over which the 119 emergency medical services were situated in relation to the dispatch and transport of urgent rescue services was examined. Addresses of patients requiring 119 emergency services were obtained and stored as individual units so that they could be analyzed in a Geographic Information System(GIS). The time taken by emergency services to reach patients and transport them to a hospital or other facility was measured in seconds. By inputting additional information such as the location of the 119 dispatch centers, jurisdictions, and emergency medical facilities, the GIS allowed for analyses not only of the temporal but also the spatial aspects of emergency medical services. The results showed that of 16 Gu/Gun and 226 Eup/Myen/Dong in the Busan area, only 41% of Busan's emergency medical services could respond to and transport patients within five minutes. In all districts, most emergency medical services were provided within five to ten minutes. However, the pattern of hospital use to transfer patients to hospitals was inefficient. Based on the temporal and spatial distributions of fire stations and emergency medical agencies, and on their dispatch and transport times, this study sets out and compares ideal dispatch and transportation patterns for the efficient use of Busan's emergency medical services and resources.

  • PDF

A Study on Practical Analyzing and Improving Disaster Management Organization of Korean Government (재난관리조직의 실태분석과 발전방안)

  • 권오한;남상화;이춘하
    • Fire Science and Engineering
    • /
    • v.15 no.1
    • /
    • pp.127-138
    • /
    • 2001
  • I. introduction. A government goal at the present is established to make a welfare nation and to keep people's safe living, but it is criticised that when a large-scale disaster happens, the authority concerned could not deal with it, causing many people injured and material damage. Moreover, in these days, cities have many risk factors. extremely large and intelligent building, industrial facilities and underground equipment have many risk themselves along with scientific progress. The cope with disaster effectively, government must have efficient organization, skillful personnel, tool, facilities and so on. To reduce the damages, what's the most effective government organization\ulcorner II. Government organization for managing disaster In a few decades, a large-sized accidents broke out in korea, for example, collapse of Sampoong department store, break of Sungso bridge, explosion of Daegu city gas, gas explosion accident at Ahyon-dong etc. but government has not any adequate disaster response organization. Especially, after collapse of Sampoong department store broke out, Disaster Management Act is enacted to solve the past problem. According to Disaster management Act, disaster is limited in manmaid disaster. Therefore, in this thesis, disaster management is inspected theoretically, organization of disaster management for pattern of disaster, and role, duty of government organization, emergency relief organization system and actual conditions are analyzed. there are some problems. there are trials and errors. the government has changed the disaster management organization by the disaster management law. the organization consists of central and local government. but both of government do not work together harmoniously. in thesis, I would like to introduce the advanced nations disaster management organization, and study our central, local government organization. III. Conclusion Change and development of the government disaster management organization is the goal of this thesis. we have to increase public service in response and manage disaster. protecting civilian's life from the disaster is very important responsibility of government. there would be better way of government disaster management organization.

  • PDF

A Study on Analysis of efficient Shelter Guide For Multiple-use Facilities (다중이용시설물에서의 효율적인 피난유도에 관한 현황 분석)

  • Park, In-Sook;Kim, Whoi-Yul;Kim, Byeoung-Su;Ahn, Byung-Ju;Lee, Yoon-Sun;Kim, Jae-Jun
    • Proceedings of the Korean Institute Of Construction Engineering and Management
    • /
    • 2007.11a
    • /
    • pp.791-796
    • /
    • 2007
  • As large-scale buildings, skyscrapers, and multi-purpose buildings recently increase in numbers dramatically, the internal space of such buildings becomes more and more large and complicated accordingly. Since such structures usually accommodate a number of random people, the potential possibilities of disastrous tragedies are high, and the rates of injury and physical damage caused by the complicated system of the building also increase as well. However, most of the shelter designs of the existing buildings are based on the specifications according to the assigned laws and involved regulations. In this case, only general criteria are referred to regardless of the characteristics of each structure while other disaster-related features are not taken into consideration sufficiently. Since any actual fire may cause a terrible calamity, in such plans, shelter inducement can be neither safe nor effective. Thus, this study examines and analyzes currently run disaster prevention systems and shelter inducement facilities with COEX Mall as its subject, and analyzes the responding system to each situation based on the fire scenarios by means of As-Is Model. Through this analysis, presented are the measures to solve the problems of current disaster prevention systems and to improve shelter inducement methods effectively.

  • PDF