• 제목/요약/키워드: Fire facilities

검색결과 835건 처리시간 0.03초

소규모 산업시설의 초고속 화재 확산 방지를 위한 방호벽체 개발 연구 (Study on the Development of Protective Walls to prevent the spread of Ultra-Fast Fire in Small Industrial Facilities)

  • 최경철;김홍섭
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2023년도 가을학술발표대회논문집
    • /
    • pp.275-276
    • /
    • 2023
  • This study introduces the current progress of study on the development of protective wall aimed at preventing the spread of ultra-fast fires and ensuring fire safety in industrial facilities.

  • PDF

업무시설의 화재성상예측을 위한 가연물 조사 및 화재하중 제안 (A Suggestion on the Fire load and Combustible survey for Prediction of Fire in office Facilities)

  • 이병흔;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2019년도 추계 학술논문 발표대회
    • /
    • pp.98-99
    • /
    • 2019
  • In Korea, buildings are becoming skyscrapers due to restrictions on land. The performance-oriented design was introduced in 2009 for fire safety of such buildings, but the application of the combustible data through engineering design and experiment is a poor reality. Large buildings are used for complex purposes, especially since the density of the office facilities is high, the study conducted a study on the combustible materials of the office facilities and the thermal speed and fire load of the main combustibles of the office facilities were calculated.

  • PDF

복합 영화상영관의 화재안전성능 개선대책에 관한 연구 (A Study on Measures to Acquire Fire Safety Performance of Multiplex Movie Theaters)

  • 손봉세;장희철;김태국
    • 한국화재소방학회논문지
    • /
    • 제20권4호
    • /
    • pp.116-124
    • /
    • 2006
  • 복합 영화관은 여러 계층 및 연령대의 불특정다수인이 동시에 영화를 편안하게 즐길 수 있는 문화공간이다. 이러한 다중이 이용하는 시설은 다른 일반 소방대상물에 비하여 상대적으로 안전에 취약한 점을 가지고 있다. 본 연구에서는 현재 국내에 있는 기존의 복합 상영관의 대표적인 모델을 선정하여 화재 및 피난시뮬레이션을 실시하여 피난안전에 대한 문제점을 분석하고, 각국의 관련기준과 비교하여 화재안전성능 확보에 필요한 내용을 파악하였다.

Evaluation of Escape Safety Depending on the Number of Users of Residential Convenience Facilities in the Apartment Complex and the Kind of Elevators

  • Cho, Seong-Suk;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • 제9권4호
    • /
    • pp.376-384
    • /
    • 2021
  • This study wants to provide basic data on effective escape safety plans when residents of apartment complex use residential convenience facilities. The findings of the analysis are as follows. First, when this study applied the actual number of users (No=54) of those facilities, the existence of elevator for escape reduced the escape time by 189.0 seconds. Second, when the number of users was calculated on the standard of the number of people who can be accommodated for performance based design (No=316), the existence of the elevator for escape reduced the escape time by 173.5 seconds. Finally, when the number of users was calculated on the standard of installing fire-fighting facilities (No=122), the existence of the elevator for escape reduced the escape time by 159.2 seconds. As a result, it was found that elevator for escape reduces the escape time from fire. Accordingly, it is necessary to revise the construction law to make it obligatory for residential convenience facilities to be equipped with elevator for escape. Currently, apartment buildings lower than 30 stories have either elevator for passengers or elevator for escape. Thus, in future studies, it is necessary to compare escape times in fire depending on the kinds of elevator, and identify the usefulness of elevator for escape.

산불방지 급수시설 설치 기준 마련에 관한 연구 (Study on Guideline of Water Supply System for Forest Fire)

  • 김동현;남송희;금시훈
    • 한국화재소방학회논문지
    • /
    • 제27권3호
    • /
    • pp.38-46
    • /
    • 2013
  • 산불로부터 주요 산림과 시설물들을 보호하고 주변 확산을 저지하기 위해서는 상설 급수 및 살수시설이 반드시 필요하다. 우리나라에서는 2005년 양양산불로 인해 낙산사 소실을 경험하면서 주요문화재 건축물 주변에 숲 관리와 함께 산불방지 급수시설 설치사업을 단계적으로 실시하였다. 하지만 기존 설치된 산불방지급수시설의 경우, 별도의 설치와 관리를 위한 기준을 마련하지 않고 각 시공업체의 시방서를 기준으로 설치하였다. 시공업체의 시방서는 NFSC 109를 토대로 산림지역에 변형하여 설치한 것으로 광범위한 산불확산으로부터 주요시설물 등을 효과적으로 보호하기에는 방호면적이 적고 호스의 이동과 동시살수에 있어 제한적인 단점들을 가지고 있다. 이에 본 연구에서는 국내에서 설치되어 이용하고 있는 산불방지 급수전의 실태조사를 실시하여 문제점들을 도출하였고 이를 보완할 수 있는 성능위주의 산불방지 급수시설 기준을 마련하였다. 그 결과, 산불방지 효과를 높이기 위한 방법으로 산불방지 급수시설의 구성을 수관화 확산방지를 위한 'Water Sprinkler Tower System', 지표화 진화를 위한 'Forest Fire Hydrant System', 'Portable Water Spray System' 3가지를 제시하였고 설치를 위한 펌프의 성능 및 부속품들에 대한 기준을 제시하였다.

주거시설 화재성상예측을 위한 가연물 연소특성에 관한 연구 (A Study on the combustible materials Combustion Characteristics in residential facilities fire behavior prediction)

  • 김동은;김기현;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.103-104
    • /
    • 2013
  • As a result of experimenting 6 loading combustibles in domestic residential facilities by using Furniture Calorimeter, values of 2,391.26kW were appeared from sofas, 1,891.80kW from drawers, 1,778.95kW from mattress, 1,104kW from chairs, 291kW from tables, and 135.09kW from TV. Also, if applying α value of fire growing rate by classifying fire- growing speeds at NFPA 72 (National Fire Alarm Code 2007, Annex B), mattress can be defined as Ultra-Fast, sofa and drawers Fast, TV Slow, tables Slow, and chairs Medium.

  • PDF

화재방호 설비 설계 자동화를 위한 선행연구 및 기술 분석 (Literature Review and Current Trends of Automated Design for Fire Protection Facilities)

  • 홍성협;최두찬;이광호
    • 토지주택연구
    • /
    • 제11권4호
    • /
    • pp.99-104
    • /
    • 2020
  • This paper presents the recent research developments identified through a review of literature on the application of artificial intelligence in developing automated designs of fire protection facilities. The literature review covered research related to image recognition and applicable neural networks. Firstly, it was found that convolutional neural network (CNN) may be applied to the development of automating the design of fire protection facilities. It requires a high level of object detection accuracy necessitating the classification of each object making up the image. Secondly, to ensure accurate object detection and building information, the data need to be pulled from architectural drawings. Thirdly, by applying image recognition and classification, this can be done by extracting wall and surface information using dimension lines and pixels. All combined, the current review of literature strongly indicates that it is possible to develop automated designs for fire protection utilizing artificial intelligence.

화재발생 요인에 따른 특정관리대상시설등의 위험도 평가 지수의 분석 및 개발 (Development of Risk Assessment Index in Special Management Target Facilities According to the Fire Occurrence Factors)

  • 박미연;박종복;박재학
    • 한국방재안전학회논문집
    • /
    • 제5권2호
    • /
    • pp.61-70
    • /
    • 2012
  • 특정관리 대상 시설의 범위는 건축물 분야와 토목 시설물 분야로 구분되며 이들 시설 중 본 연구에서는 건축물 분야의 주거와 비주거시설에 대한 최근 5년간 발생한 화재발생을 중심으로 위험도 분석을 수행하였다. 주거시설 및 비 주거시설에서 발생한 화재사건은 전기적 원인에 의한 화재발생이 가장 많았으며 이로 인한 인명 피해 또한 매우 높은 것으로 분석되었다. 따라서 본 연구에서는 화재가 발생하게 된 원인적인 내용을 규명하고 이를 근거로 각 시설물 별 화재에 얼마나 위험한 수준인지를 위험도 평가지수 개발을 통해 분석하였다. 본 분석은 향후 이들 시설의 안전 관리를 위한 기준으로 활용될 수 있으며 이를 바탕으로 좀 더 전문적이고 집중적인 안전관리를 유도할 수 있을 것으로 판단된다.

화목 연료 난방설비의 화재 위험 감소 방안에 관한 이론적 연구 (Study on the effective response method to reduce fire risk of wood fuel heating system)

  • 박경진;이봉우;이근출;남기훈
    • 한국산업융합학회 논문집
    • /
    • 제22권2호
    • /
    • pp.163-171
    • /
    • 2019
  • Recently, rural housing in urban areas has been increasing due to the improvement of income level. With the increase of the construction of the power house, the installation of the heating system using the harmonious fuel for the purpose of heating and the beauty of the room is increasing rapidly. In addition to the increasing use of firewood heating equipment, the incidence of fire is also increasing. Analysis of the National Fire Data System of the Fire Department The result of the analysis of the National Fire Data System Many parts of the fire are incinerated by the accumulation of tar due to the incompleteness of periodic cleaning inside the cylinder. The distance between the fire extinguisher and the combustible materials such as ceiling, Resulting in fire. In addition, it was found that much of the fire of the firewood heating system in the time zone occurs during the sleeping and resting time and there is not enough time for the residents to cope. This, in turn, causes serious harm to the lives and property of the users of the pyrotechnic heating system. Therefore, in this study, domestic and foreign standards and laws related to fuel oil heating facilities were analyzed and 12 cases of fire accidents were analyzed. Through the revision of the fire prevention and firefighting facilities installation and maintenance law, the installation standards of the alarm and fire extinguishing facilities were presented.