• 제목/요약/키워드: Fire explosion

검색결과 637건 처리시간 0.023초

실내 피난경로 선택 특성 (A Study on Behavior Characteristics through Way Decision of Indoor Evacuation)

  • 황광일;심영훈;김현성
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2014년도 추계학술대회
    • /
    • pp.268-269
    • /
    • 2014
  • 본 연구는 일반인들이 화재, 지진, 폭발 등 재난에 직면했을 때의 실내 피난 경로 선택에 대한 특성을 파악하기 위한 목적으로 수행하였다. 조사결과, 화재, 재난 발생 시 나타나는 다수의 피난 행동 특성을 확인 할 수 있었다.

  • PDF

장기 계류 어선에 대한 보험자의 면책에 관한 연구 (A Study on Exemption of Insurer for a Long Period Laid-up Fishing Vessel)

  • 박용섭;차철표
    • 수산해양교육연구
    • /
    • 제5권2호
    • /
    • pp.110-118
    • /
    • 1993
  • A squid gill-net fishing vessel Jayueoroho which was being insured ITC-Hulls and was laid up long period illegally under the condition of unmanned in the Pert of Kamcheon. On 30, March, 1993, the fishing vessel moved out toward the high sea by assistance of two tugboats, 12 miles southeast from Teajongdae, to discharge sewage. At that time the shipowner, the skipper, chief engineer and two labourers were boarding, and a fire was broken out by electric leakage at sea. For all their efforts of fire-fighting operation the fishing vessel foundered with explosion. In this case, she had been breached the warranties of legality, especially Korean maritime acts concerned, and the warranties of seaworthiness(MIA 39(5)) as attributable cause because of unmanned on board by wilful misconduct of the insured. Therefore it is prima facie evidence that the insurer is not liable for any loss attributable to the wilful misconduct and breach of warranties of the insured in MIA 1906.

  • PDF

고강도 콘크리트 내화피복 특성연구 (A study on the characteristic of fire protection covering for high strength concrete)

  • 송영찬;이세현;김우재;양완희;박동철;백병훈
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.429-432
    • /
    • 2006
  • In this study a board was made with good fireproof materials of which test was conducted according to the fireproof test for KS F 2257 construction members, and the temperature in coated steel which has a possibility to explode with concrete surface was measured. It is not appropriate to use normal mortar or mortar covering mixed with P.P. fiber to take a measure to prevent the explosive splalling of high-strength concrete. To finalize an Al-Si (aluminosilicates) board-requires over 30mm in thickness at the minimum for the required fire resistance performance and explosion prevention.

  • PDF

밀폐계 측정장치를 이용한 물-노말프로판올 계의 인화점 (Flash Points of Water+n-Propanol System Using Closed-Cup Measurement Apparatus)

  • 하동명;최용찬;이성진
    • 한국안전학회지
    • /
    • 제17권4호
    • /
    • pp.140-145
    • /
    • 2002
  • The Flash Point is one of the most important combustible properties used to determine the potential for fire and explosion hazards of chemical materials. An accurate knowledge of the flash point is important in developing appropriate preventive and control measures in industrial fire protection. The lower flash points for the Water + n-Propanol systems were measured by using Pensky-Martens closed cup tester. The experimental data were compared with the values calculated by the laws of Raoult and van laar equation. The calculated values based on the van Laar equation were found to be better than those based on the Raoult's law.

Planning for Safely Control on Hazardous Material Distribution Depot.

  • Roh, S.K.;Jun, S.W.;Kang, T.H.;Seo, Y.M.
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.260-268
    • /
    • 1997
  • The safety of LPG vessel storage has been simply designed and controled with blast wave barrier structure concept regardless of its quantity or hazardous situation. The limit of regal controls on LPG vessel storage need to be identified in terms of safety buffer distance from LPG explosion. The level of overpressure effect and heat radiation In the safety structure and neighbouring human activity required to be estimated to find the gap between existing controls on such storage. To this content the paper discuss the issues on the approach In the blast wave barrier and safety separation distances.

  • PDF

재유화형 폴리머를 혼입한 폴리머 시멘트 모르타르의 내화특성 (Fundamental Properties Polymer-Modified Mortars Using Re-dispersible Polymer Powder)

  • 장건영;류동우
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.35-41
    • /
    • 2019
  • In this study, the fire resistance performance of polymer cement mortars which are used as a representative repair material for section restoration, is evaluated and residual bond strength is measured by considering unity with concrete. According to the evaluation of fire resistance performance of re-emulsification type polymer cement mortars, residual compressive strength was drastically decreased according to heating temperatures with an increase of polymer addition rate, and this seems to be attributable to the application of polymer film. In addition, an explosion phenomenon occurred frequently with an increase of addition rate, so this should be considered when selecting repair materials and processing.

Analysis of Secondary Battery Trends Using Topic Modeling: Focusing on Solid-State Batteries

  • Chunghyun Do;Yong Jin Kim
    • Asian Journal of Innovation and Policy
    • /
    • 제12권3호
    • /
    • pp.345-362
    • /
    • 2023
  • As the widespread adoption and proliferation of electric vehicles continue, the secondary battery market is experiencing rapid growth. However, lithium-ion batteries, which constitute a majority of secondary batteries, present high risks of fire and explosion. Solid-state batteries are thus garnering attention as the next-generation batteries since they eliminate fire hazards and significantly reduce the risk of explosions. Against this background, the study aimed to analyze research trends and provide insights by examining 2,927 domestic papers related to solid-state batteries over the past decade (2013-2022). Specifically, we used topic modeling to extract major keywords associated with solid-state batteries research and to explore the network characteristics across major topics. The changes in research on solid-state batteries were analyzed in-depth by calculating topic dominance by year. The findings provide an overview of the emerging trends in domestic solid-state battery research, and might serve as a valuable reference in shaping long-term research directions.

도로터널에서 수소 연료차 수소탱크 폭발시 폭발압력에 대한 기초적 연구 (A basic study on explosion pressure of hydrogen tank for hydrogen fueled vehicles in road tunnels)

  • 류지오;안상호;이후영
    • 한국터널지하공간학회 논문집
    • /
    • 제23권6호
    • /
    • pp.517-534
    • /
    • 2021
  • 수소연료는 환경오염문제를 해소하고 에너지 불균형 및 비용을 절감할 수 있다는 점에서는 화석연료를 대체하는 에너지원으로 부각되고 있다. 수소는 친환경적이나 폭발성이 강하기 때문에 수소연료차의 화재, 폭발 사고에 대한 우려가 매우 높은 실정이다. 연구결과에서 수소사고는 일반적인 화재의 경우 비교적 안전하나, 폭발이 발생하면 매우 위험한 것으로 인식되고 있다. 특히, 터널과 같은 반밀폐공간에서는 위험도가 보다 증가할 것으로 예측되기에 이에 대한 예측방법 및 대책을 마련하기 위한 연구가 수행되고 있다. 이에 본 연구에서는 터널에서 수소폭발시 안전성을 평가하기 위해서 등가 TNT모델의 적용성과 수치해석 방법에 대한 검토를 수행하였다. 6개의 등가 TNT모델과 Weyandt의 실험결과의 폭발압력을 비교·검토하여 모델의 적용성을 평가한 결과, Henrych식이 13.6%의 편차로 가장 근접하는 것으로 나타났다. 수치해석을 이용하여 수소탱크 용량(52, 72, 156 L)과 터널 단면적(40.5, 54, 72, 95 m2)이 폭발압력에 미치는 영향에 대한 검토한 결과, 터널에서 폭발 압력파는 초기에는 대기중에서와 마찬가지로 반구형 형태로 전파되나 벽체에 도달하면 반사파가 형성되며, 일정 거리 이상에서는 평면파로 변형되어 아주 완만한 감쇄율로 전파하는 것으로 나타났다. 등가 TNT모델인 Henrych식은 폭발압력이 급격하게 감소하는 구간에서는 수치해석 결과와 잘 일치하나 폭발압력파가 변형된 이후에는 큰 폭으로 과소평가하는 것으로 나타났다. 수소탱크용량이 동일한 경우에는 터널 단면적이 증가할수록 폭발압력이 감소하며, 단면적이 동일한 경우에는 수소탱크 용량이 52 L에서 156 L로 증가하면 폭발압력은 약 2.5배 정도 증가하는 것으로 나타났다. 인체에 영향을 미치는 한계거리에 대한 평가결과, 수소탱크용량이 52 L인 경우 사망에 이르는 한계거리는 약 3 m, 중상에 이르는 거리는 단면적별로 차이가 있으나 28.5~35.8 m로 나타났다.

수소충전소 방호벽 안전성 검증을 위한 TNT 폭발실증 및 전산유동 해석 (TNT Explosion Demonstration and Computational Fluid Dynamics for Safety Verification of Protection Wall in Hydrogen Refueling Station)

  • 양윤영;조재근;박우일;나현빈
    • 한국가스학회지
    • /
    • 제27권4호
    • /
    • pp.102-109
    • /
    • 2023
  • 수소사회 실현에 있어 수요자가 수소를 가장 쉽게 만날 수 있는 시설인 수소충전소의 안전 확보가 중요하다. 수소충전소는 고압의 수소를 저장하는 압축가스설비 등으로 구성되어 있으며, 시설 내 수소 누출로 인한 화재폭발 또는 주변 화재의 영향으로 고압의 압축가스설비가 파열될 위험이 있다. 이에, 한국가스안전공사는 설치단계부터 위험요인을 찾아내 설계에 반영하고 법정 검사를 통한 안전 확보에 만전을 다하고 있다. 본 연구에서는 수소충전소에 설치하는 방호벽의 안전성 효과를 확인하기 위해 방호벽을 이용한 TNT 폭발 실증시험을 실시하고, CFD 프로그램인 FLACS-CFD를 이용하여 실증시험 결과와 비교·검증하였다. 실증시험 및 CFD 해석 결과 방호벽 후단에서 폭발 과압의 감소 효과가 위치에 따라 50 %에서 최대 90 %까지 감소하는 것이 확인되나, 일정거리를 벗어나면 그 효과가 떨어지는 것을 확인하였다. 방호벽의 안전성 검증을 위한 실증시험 및 전산해석 결과는 향후 방호벽 기준 최적화를 위한 제안에 활용하고자 한다.