• 제목/요약/키워드: Fire experiment

검색결과 801건 처리시간 0.025초

비닐절연전선의 산화물 성장 특성과 화재조사에의 적용 (Copper Oxide Growing Characteristics of PVC Insulated Wire and Application to the Fire Investigation)

  • 김향곤;최충석;김동욱;최효상
    • 전기학회논문지P
    • /
    • 제56권1호
    • /
    • pp.37-44
    • /
    • 2007
  • This paper describes characteristics for copper oxide growth of polyvinyl chloride(PVC) insulated wires by series arc. In this experiment, 600V IV wires were used, and characteristics of oxide growth and ignition process were analyzed in case load was 300W, 460W and 600W, respectively. In the result of experiment, covering materials were molten, carbonized and ignited, whereas, oxidized materials were grown in conducting material. During copper oxide was growing, contact voltages and power dissipations increased. When there is copper oxide growth, the waveform of current showed sinusoidal waveform, and the waveform of voltage showed modified waveform. Oxidized materials were heated at about $905^{\circ}C$, surface structure showed irregular shapes, and cross-section showed multiple cracks. And, the results of this experiment were applied to the fire cause analysis of fire evidence collected at the fire scene.

굴참나무 낙엽의 Fire Whirl 특성에 관한 실험 및 수치해석 연구 (Numerical and Experimental Study on the Fire Whirl Characteristics of Oriental Oak Leaves)

  • 배승용;유홍선;홍기배
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.73-78
    • /
    • 2009
  • Fire whirl은 도시 및 산림화재와 같이 광범위한 지형에서 주로 발생하며, 화염주위 환경의 불안전성에 의해 발생하는 현상이다. Fire whirl은 드물게 발생하지만, 높은 흡입력과 양력을 가지게 되어 연소속도를 증가시키는 매우 위험한 현상이다. 본 연구에서는 산림화재에서 발생하는 fire whirl 특성에 대한 고찰을 위해 굴참나무 낙엽을 이용한 fire whirl 실험 및 수치해석 연구를 실시하였다. 실험 결과 유입공기의 속도가 증가함에 따라 화원주위의 회전강도가 증가하여 발열량 및 화염길이가 일반 풀화재에 비해 최대 22.8%, 18.4% 증가하였으며, 수치해석은 실험결과와 유사한 경향을 나타내었다.

스프링클러헤드 응답성에 관한 실험적 연구 (An Experimental Study on the Responsiveness of Sprinkler Heads)

  • 김동석;박용일;박희용
    • 한국화재소방학회논문지
    • /
    • 제7권2호
    • /
    • pp.3-12
    • /
    • 1993
  • The closed type sprinkler head is a component of sprinkler system for fire protection. The purpose of this study is to inverstigate the influence factors of the responsiveness of the head by heated wind tunnel experiment. As the result of this study, it was found that response time index and conduction parameter showed the same characteristic quantitative changes to head types and test methods.

  • PDF

건축물 창호의 화재안전설계를 위한 실험적 연구 (An Experimental Study on the Fire Safety Design of Windows in Building)

  • 이병흔;진승현;한지우;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2018년도 춘계 학술논문 발표대회
    • /
    • pp.10-11
    • /
    • 2018
  • In the building, the opening penetrates the wall and serves as a spreading channel for smoke and flame in case of fire. In Korea, more than 1,500 fire plume are generated annually, and the number has increased by about 30% over the past five years. Therefore, in the case of windows protecting the opening, fire protection performance is important to prevent the spread of fire. However, in Korea, the standard for window is not clear. In this study, fire tests (EN 13823) for windows were conducted in Korea, and then fire protection performance of windows was compared. As a result of the experiment, PVC windows showed a phenomenon that they could not withstand the temperature during the fire experiment, and AL windows showed a difference in the degree of cracking of the glass.

  • PDF

실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구 (Basic Research on Potential Application of Fire Detection by Measuring Fire Detection Tendency of Indoor Air Quality Measurement Factors)

  • 최수길;진세영;박상민;남영재;김시국
    • 한국화재소방학회논문지
    • /
    • 제34권1호
    • /
    • pp.37-46
    • /
    • 2020
  • 본 논문은 실내공기질 측정인자들의 화재감지 경향성 측정을 통한 화재감지 활용 가능성에 관한 기초 연구이다. 공기질 측정인자들의 화재감지 경향성을 측정하기 위해 연기감지기 감도시험기를 이용한 작동실험과 UL 268에서 규정하고 있는 종이화재실험을 진행하였다. 연기감지기 감도시험기를 이용한 작동실험 및 UL 268 종이화재실험에 측정된 각각의 측정값을 교차 대입한 결과 공기질 측정기(IAQ) S1의 경우 PM 10(평균값제외), HCHO(평균값 및 최대값 제외), IAQ S2의 경우 PM 1.0, PM 2.5, PM 10, 연소가스분석기(CGA)의 경우 CO(평균값 및 최대값 제외)가 모든 실험 조건에서 연기발생에 따른 측정값의 변화를 통해 경향성을 관찰할 수 있었다. 특히, 본 실험 조건에서 측정되는 인자들 중 적응성이 가장 우수한 PM 10 및 CO는 화재감지 인자로 활용 가능할 것으로 생각된다.

A study on the fire performance and heat transfer of the HPC column with fiber-cocktail in ISO fire under loading condition

  • Kim, Hyung-Jun;Kim, Heung-Youl;Kwon, In Kyu;Kwon, Ki-Hyuk;Min, Byung-Yeol;Cho, Bum-Yean
    • Computers and Concrete
    • /
    • 제12권5호
    • /
    • pp.717-737
    • /
    • 2013
  • In this study, experiment and numerical analysis were conducted to identify the heat transfer characteristics and behavior of high-strength concrete upon a fire. The numerical analysis was employed to forecast the characteristics and properties of the high-strength concrete upon a fire, which can not be accomplished through a fire test due to the specific conditions and restrictions associated with the test. The result of the numerical analysis was compared with that of the test to verify the reliability of the analysis. In the numerical analysis of the heat transfer characteristics and behavior of 80 and 100 MPa high-strength concrete upon a fire, the commercial software of ABAQUS(V.6.8) was used. It was observed from the experiment that the contraction of the concrete with fiber-cocktail was mitigated by 25~55 % compared with that without fiber-cocktail because the fiber controlled the heat transfer of the concrete and thus improved the fire-resistance performance of the column.

무선통신기능을 갖는 화재감지기 회로에 대한 연구 (The Study of Fire Detector Circuit with Wireless Communication)

  • 백동현;김장원
    • 한국화재소방학회논문지
    • /
    • 제24권1호
    • /
    • pp.111-115
    • /
    • 2010
  • 본 논문은 단독형 화재감지기에 무선통신기능을 융합한 화재감지장치를 개발하고자 ZigBee 통신기술을 단독형화재감지기의 신호처리방식으로 채택하여 무선 네트워크와 결합이 가능하도록 설계하였다. 화재감지시 출력전압은 0.4V, 동작 펄스폭은 $600{\mu}s$로 실험하였다. LED감시등은 30초 주기로 동작하고 0.12mA, 동작시에는 0.5초 주기로 하며 사용전류가 7mA가 흐르도록 하여 전원회로, Chamber테스트, 연기테스트, IRED, LED 점등등 각 부분이 일정 시간 내에 정상적으로 동작되어 그 적정성을 확인하였다.

아트리움 공간에서의 화재성상에 관한 축소모델 실험연구 (The Experimental Study of Fire Properties in Reduced-scale Atrium Space)

  • 류승관;김충익;유홍선
    • 한국화재소방학회논문지
    • /
    • 제13권4호
    • /
    • pp.30-37
    • /
    • 1999
  • 본 연구에서는 아트리움 공간에서의 화재성상을 파악하기 위해 실물 실현의 대안으로서 축소 모형 실험을 수행하였다. 연속방정식, 운동량 보존 방정식, 에너지 보존 방정식과 같은 지배 방정식의 차원해석으로부터 추론된 $\pi$변수로부터 축소법칙을 얻었다. 이 축소법칙에 따라 일본의 시반스 아트리움을 1/50로 축소한 모형에서 실험을 수행하였다. 여기서 얻어진결과를 실물 실험 결과와 비교하였다. 더 나아가 이러한 결과들은 레이저 관광을 이용한 가시화 시스템에 의해 가시화 되어졌다.

  • PDF

중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구 (A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test)

  • 민세홍;김미숙
    • 대한안전경영과학회지
    • /
    • 제12권1호
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

그라인딩 작업 중 발생하는 불티의 화재 예방에 관한 연구 (A Study on the Risk of Fire Caused by Sparks during Grinding Operation)

  • 김성은;이근출;박경진
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.751-756
    • /
    • 2023
  • In this study, We investigated a fire case and performed an experiment to prevent fire from sparks that is generated during grinding operation. Before conduct the test, confirmed that the generating mechanism of fire-flakes in working grinder and the fire experiment was conducted using commonly tools, flammable materials in industrial field. in result, It could be measured scattering distance, temperature, ignition possibility by type of combustible materials. Based on the results of this study, We are expected to be used as basic data for fire prevention in grinding Industry.