• Title/Summary/Keyword: Fire escape

Search Result 232, Processing Time 0.025 seconds

A Study on the Improvement of Fire Evacuation Scenario Using Delphi Technique -Focus on The Mobile Application and psychology- (델파이 기법을 활용한 화재피난 시나리오 개선 연구- 모바일 어플리케이션과 재실자 심리를 중심으로 -)

  • Lee, Sang ki;Kim, Sung Hyun
    • Journal of Service Research and Studies
    • /
    • v.12 no.2
    • /
    • pp.23-37
    • /
    • 2022
  • Based on the service scenario proposed by the existing Kim Tae-wan (2018) who can safely evacuate inmates with the help of a mobile application linked to a fire detection system in the event of a fire, the final purpose of this study is to develop the scenario by incorporating more realistic scenarios with mobile stimuli that can help them escape or act through the Delph In addition, to make the scenarios produced more realistic considering the structure and copper lines of a typical building, expert scenario verification and Delphi technique were applied to exclude unnecessary or impractical aspects of the existing scenarios. The results of the second Delphi survey showed that the primary psychology that could be seen at the time of the fire alarm were doubts, safety concerns and alarm, and the results of the second Delphi survey were analyzed, and the satisfaction of the content adequacy (CVR), convergence, and consensus was derived. Finally, this was applied to create a scenario in which a mobile application was assisted to evacuate the fire response phase. This study will allow the use of methods to increase the evacuation rate of those who are in the event of a fire.

A Study on Effective Fire Countermeasures for Facilities for the Elderly and Children (노유자시설의 효율적인 화재 대응방안에 관한 연구)

  • Hwang, Euy-Hong;Choi, Han-Bit;Choi, Doon-Mook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.107-114
    • /
    • 2020
  • With the development of the national industry, the importance of the elderly and children such as the elderly, disabled, and children is recognized. Similarly, the number of facilities for the elderly and children is increasing. Fires at facilities for the elderly and children cause heavy casualties. In response to these events, it is essential to activate fire alarms promptly and accurately and to secure evacuation routes. In this study, the laws and statistics related to facilities for elderly and children were reviewed, and problems with legal terms-such as elderly, children, others, unwanted alarm of fire alarm systems, blind spots of fire compartment standards, securing evacuation routes, and absence of standards for life safety rescue organizations-were identified. As an improvement measure, the legal definitions of similar terms-such as elderly, children, unwanted alarm checklist, and establishment of standards for fire prevention compartment-and introduction of other terms-evacuation elevators, the establishment of standards for life-safety rescue organizations, and provision of flame retardation objects for evacuees-were proposed.

A Case Study on the Passengers' Evacuation Times according to the Fire Smoke Density On a Ship (선박 화재 시 선내의 연기농도가 승객의 피난시간에 미치는 영향)

  • Hwang, Kwang-Il;Shin, Dong-Keol;Kim, You-Jin;Youn, Jeong-Ha;Lee, Sang-Il;Hong, Won-Hwa
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.2
    • /
    • pp.336-343
    • /
    • 2009
  • Because ships are very isolated and independent objects when sailing on the ocean, if a fire and smoke occurs, nobody can be sure to escape safely from ship at the moment. On the focus of the relationship between the sight transmissivity by fire smoke density and the life safety, this study performs simulations and experiments, respectively. To evaluate the theoretical evacuation time, CFAST software which is known as a 2 zone model analysis tool is used, and the result is 54 seconds from ECR(Engine Control Room) exit to upper deck exit and 34 seconds from bosun store to upper deck exit. And totally 12 types of experiments are performed with other 10 persons per experiment. As the result, it is cleared that the low sight transmissivity leads to the low life safety and the obstruction which can be happen unexpectedly on the evacuation way on fire makes it worse. At the condition of the smoke density 0%, over 90% people arrive at upper deck exit safely. But with the transmissivity of 8%, 70%(from ECR) and 30%(from bosun store) among experiment persons of each can survive, and with same density and unexpected obstruction, the survival ratio goes down to only 20% and 10%.

Numerical Analysis on Pressurization System of Smoke Control in Consideration of Flow Rate of Supply and Leakage (보충량과 누설량을 고려한 급기가압 제연시스템의 수치해석 연구)

  • Kim, Jung-Yup;Shin, Hyun-Joon
    • Fire Science and Engineering
    • /
    • v.24 no.5
    • /
    • pp.87-93
    • /
    • 2010
  • The fact that the smoke hinders evacuation and fire-fighting activities as well as becomes the major cause of life casualty emphasizes the importance of smoke control system. As one of the fire safety standards designed to secure the smoke safety, NFSC501A (Design Guide for Smoke Control System of Special Evacuation Stairwell and Lobby) has been proposed, preventing smoke from penetrating into the smoke-free escape route by raising the pressure of the smoke control zone higher than fire area. For model building of 20 stories, pressurization system was designed according to standard and pressure field of compartments in whole building induced by pressurization system was analyzed using the network model.

Fire Risk Assessment for Subway Station According to Supply and Exhaust Conditions (지하철 승강장 급배기 조건에 따른 화재 위험성 평가)

  • Kim, Ha-Young;Rie, Dong-Ho;Kim, Jung-Yup
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.29-34
    • /
    • 2008
  • In this research, to establish the emission for the people who are clearing out, through the numerical analysis using the CFD model, the dangerousness has been investigated in the various emission conditions in a station platform. As a result of research, it is found out that the temperature variation falls between 65.37% and 74.97% to compare without installation of platform screen doors. In the addition, with the supply mode or push-pull mode, the warm current is generated in the platform so the temperature and the layer of smoke are stirred up and felled off. It will make the dangerousness when the people escape. Therefore, when the capacity of emission and the space of platform is set up, the design regards the properties of the fire emission.

A Numerical Simulation of Smoke Control in Daegu Subway Stations II. Air Flowrate of Extraction System (대구 지하철역 제연의 문제점과 대책 II. 배기방식 제연설비의 풍량)

    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.105-110
    • /
    • 2003
  • In Part II, the temperature and smoke particle distributions of the extraction system, which yielded the best smoke removal performance among the three smoke control systems in Part I, for extraction flowrates of 0.6∼2.4 ㎥/s and two fire sizes of 200 ㎾ and 2 ㎿ were presented. The same numerical method was utilized to the same computational domain and configurations as Part I. It was shown that the extraction flowrate affects the smoke control performance significantly, and that a similar trend in improving the smoke removal performance with the increasing extraction flowrate between the two fire sizes. An extraction flowrate of 2.4 ㎥/s or higher was required for the temperature in the escape route less than $^{\circ}C$ for the given situations.

A Brief Study on Smoke Suppression Effects by Sprinkler Spray System (스프링클러설비에 의한 연기제어효과 고찰)

  • Cha, Jong-Ho;Yoon, Myung-O;Choi, Chun-Bae;Lee, Sun-Kyung
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.560-565
    • /
    • 2006
  • Sprinkler system is the most effective fire suppression with high confidence among active fire extinguishing systems. According to the installation of the related system on buildings, more separation area of fire protection can be considered to the fire protection design, and also lower differential pressure (12.5 Pascal) is permitted on lobby of fire escape stairs and emergency elevator (25 Pascal shall be considered for none sprinkler system) with economic factor. More details will be handled on the related studies.

  • PDF

An Experimental Study on The Fire Resistance Performance of Steel Encased Reinforcement Concrete and Steel Framed Mortar Beam with Loading Condition (철골 철근콘크리트 보 및 철골철망 모르타르조 보의 전열특성 및 화재거동에 관한 실험적 연구)

  • Kim, Hyung-Jun;Kim, Heung-Youl;Yeo, In-Hwan;Kwon, Ki-Hyuck;Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.80-88
    • /
    • 2012
  • This study evaluates the fire resisting capacity of the beam of the legal fire resistance construction, which establishes the Article 3 of the Regulations on Escape and Fire Resistance of Buildings. There are a total of five structures that we consider as legal fire resistance constructions, however, this study has a primary target of the reinforced concrete beam, and tests the fire-resistant performance depend on the covering depth of reinforce concrete. The results showed that it meets the three hours, the maximum statutory fire resistance time, if it was a load ratio of 0.5 and covering depth of 40 cm. Steel framed mortar beam is legal fire resistance structure that it was possessed three hours fire resistance performance, if it was a load ratio of 0.4 and covering depth of 60 mm.

A Study on the Application of Fire Protection Facilities in Large Enclosure Gymnasium (대규모 실내경기장의 소방방재설비 적용현황 분석)

  • Choi, Dong-Ho;Kim, Choon-Dong;Yang, Jeong-Hoon;Cho, Young-Hum
    • Journal of Korean Association for Spatial Structures
    • /
    • v.10 no.2
    • /
    • pp.135-145
    • /
    • 2010
  • The objective of this study is to draw basic data for the application of the fire protection planning for the future plan large enclosure buildings in Korea through an analysis of its characteristics by case studies of the domestic and foreign large scale gymnasiums. In this study, domestic building codes for the fire protection are investigated and fire detection systems, fire extinguishing systems, smoke control systems and evacuation systems of three large scale gymnasiums located at Korea and eight foreign countries are compared and analyzed. The results of this study show that infrared light fire detection system and flame detector for spacial characteristics are potentially used in fire protection systems of large scale gymnasiums: dry type sprinkler and sprinkler water gun are adopted in fire detection system; and smoke accumulation system is widely utilized in smoke control system.

  • PDF

A Study on the Analysis of Fire Risk by Fire and the Improvement of Evacuation Equipment for Apartment (About Existing 16 or Fewer Storey Apartment) (공동주택의 화재위험성 분석 및 피난시설 개선에 관한 연구 (16층 이하의 기존 공동주택을 중심으로))

  • Min, Se-Hong;Lee, Jae-Moon;Sa, Jae-Cheon;Nam, Jung-O
    • Fire Science and Engineering
    • /
    • v.25 no.6
    • /
    • pp.127-135
    • /
    • 2011
  • In this study, we assumed the kitchen fire raising the highest fire rate in apt. and analyzed the fire risk to use CFD in order to estimate the problem of evacuation equipment and the fire vulnerability of 16 or fewer storey apartment. Fire occurring in the kitchen is expended to the livingroom and other rooms. We analyzed that the temperature effected by heat was more than $60^{\circ}C$ after 90 sec in the entrance of apartment unit. If fire is early recognized by men and men don't escape in time, it have too huge demage to block the exit. When the evacuation equipment suggested in this study was installed in order to solve the problem of evacuation equipment, we analyzed that it was estimated more than safe in safety evaluation by heat and heat flux.