• Title/Summary/Keyword: Fire detector

Search Result 234, Processing Time 0.02 seconds

Analysis of Characteristics of Electrical Arc Spark Detector (전기화재 아크.스파크검출기 특성평가에 관한 연구)

  • 정용기;신효섭;지철근;김영수
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2002.11a
    • /
    • pp.375-378
    • /
    • 2002
  • An arc/spark detector (ASD) was developed is to early detect wire failures and insecure connections that may lead to fire in residents and commercial and industrial facilities. A detailed circuit design for ASD implementation along with prototype product is reported. The tests of ASD, which were successful in phase identification, in many different arc/spark locations under different loadings, and in false alarm probability, showed the ability and capability of the state-of-the-art detector in the electric fire hazard prevention.

  • PDF

Study on the Operation Characteristics of Heat Detectors through Fire and Wind Tunnel Experiment (풍동실험과 화재실험을 통한 열감지기의 동작특성에 관한 연구)

  • Ryu, Hocheol;Kim, Doohyun
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.2
    • /
    • pp.203-209
    • /
    • 2015
  • The heat detector detects heat in the fire and is an important core element of the automatic fire alarm system used generally for every fire prevention objects. The heat detector is distinguished in spot type and spread type and in spot type, there are differential and thermistor types. These heat detectors give a great influence on the loss of people and property according to the sensitivity of response such as operation time and operation temperature in actual fire and in overseas people apply it for the development of products that can be operated in the early stage of fire including certification, quality management, and comparison standard by introducing response time index through the theory of heat balance that considers the heat loss and ventilation tests. In Korea, the response time index is introduced and used in the head of sprinkler products, but it is not applied to the heat detector at present. It is necessary to introduce the response time index that shows the sensitivity of response of the heat detector the installation standard for the heat detector that the response time index is applied should be different according to the fire weight, danger degree of fire, and shape of buildings. Through this study, it tries to help reduce lives and property of people through the swift warning by installing detectors suitable for the building structure.

Fire Detection Signal Processing Method Using an Optical Fiber Linear Detector and the Development of an Optical Signal Processing Test Module (광섬유선형감지기를 이용한 화재감지 신호처리방법 및 광신호처리 시험모듈 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Young-Sin;Kim, Dong-Eun;Lim, Woo-Sub;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.27-34
    • /
    • 2016
  • This paper studies a fire detection system using an optical fiber linear detector which can minimize damage from a fire by the most adaptable even in poor environmental conditions such as a tunnel or utility-pipe conduit vulnerable to fire. Using a strand of optical fiber, temperature can be displayed in intervals of meters and a fire can be detected remotely from a distance of several kilometers. Thanks to its strengths such as high reliability and long life, it is widely applied in harsh environments in the overseas. Therefore demands are expected to grow greatly in Korea as well. However, all optical signal drive and analysis module except for the optical fiber linear detector, tend to rely on import. Firstly this study deduced the location and the method of processing signals measuring temperature by using the optical fiber linear detector in order to develop a technology for a domestic model of fire detection system. Secondly this study designed and manufactured the optical analysis test module, and then we checked its performance.

Consideration on Fire-prevention Facilities for Wooden Cultural Heritages (목조문화재 보존을 위한 소방시설에 대한 고찰)

  • Kim, Tae-Goo
    • 보존과학연구
    • /
    • s.31
    • /
    • pp.155-171
    • /
    • 2010
  • Wooden cultural heritages have many factors of fires and structural characteristics vulnerable to the fire extinguishing. Also, they are surrounded with forests and so remote from fire stations, which make it difficult to handle it quickly when fires break out. Wooden cultural heritages made of wood materials belong to the general fire in a Class A. Taking characteristics such as a smoldering and a backfire from the that fire of wooden materials into consideration, extinguishing the fire by the cooling system is the most effective. If the fire can't be put out at the early stage, it is almost impossible to protect wooden cultural heritages from the fire, because wooden structures can be destroyed in a high temperature and in a short time and it takes around average 7 minutes to reach its peak of flames in the process of a fire. According to the geographical and environmental situation of the cultural heritages, currently, the fire-prevention facilities such as the auto fire detector for the prompt detection, the water mist fire suppression system for the 1st early and urgent fire suppression and the outdoor fire hydrant and the water curtain etc. for the 2nd full-scale suppression and the prevention of the fire gaining force are being installed for the wooden cultural heritages.

  • PDF

A Study on the Development of the Single Station Fixed Temperature Detector of Low Power Consumption for Residential Fire Prevention (주택화재 예방을 위한 저소비 전력형 단독경보형 정온식감지기 개발에 관한 연구)

  • Park, Se-Hwa;Cho, Jae-Cheol
    • Fire Science and Engineering
    • /
    • v.24 no.6
    • /
    • pp.61-68
    • /
    • 2010
  • In this paper, a research and development result for the implementation of single station fixed temperature detector for residential fire prevention is described. The detector was developed for the certification in Japanese market because of very low domestic market situation. It is in the situation that there is no other regulation especially for residential detectors in Korea, Japanese case has been reviewed. Investigation of domestic legal circumstances and a comparative study for the test standard owned by KFI (Korea Institute of Fire Industry & Technology) and JFEII (Japan Fire Equipment Inspection Institute) respectively are also indicated. The detector alarms with a buzzer and an indicating LED. In the implementation ultra low power MCU(Micro Controller Unit) is applied to control the sleeping state and the monitoring state properly with low current consumption. To sense the temperature fast response thermistor is adopted in the design of fixed temperature residential detector. Automatic test function and alarm stop function are also considered in the design. The major factors which influence to current consumption are explained for the purpose of design reference. Main electronics circuit parts related to it's characteristics of the detector are described. It is explained that the measured current and experimental result of the battery discharge can be met over 10 years operation.

A Study on Design and Implementation of an Analog Addressable Detector and a Fire Alarm System (아날로그 주소형 감지기와 자동화재탐지 시스템의 설계 및 구현사례에 대한 고찰)

  • Kim, Chong-Tai;Hong, Se-Kwun;Yoo, Young-Shin;Jung, Hae-Sung
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.1-11
    • /
    • 2010
  • This paper describes a design and implementation of an analog detector and a fire alarm system with recent technology on information and communication. A hierarchical architecture design from the detector to the main system enables to accommodate medium to large size buildings located nearby or far-away. And a software design from communication protocol to application program handles large amount of events efficiently to show information on a large LCD. A PC-based alarm system provides higher speed and larger capacity in a large LCD screen compared with foreign microprocessor-based small screen systems. Thus, very large buildings with several thousands of analog detectors can be easily covered in a single system. When an alarm occurs, a staff alarm scenario specially attempted only in the system is considered to play a major role to distinguish a real fire from unwanted alarms.

Performance Analysis of the the Single Alarm Detector in the Rooms of Single Houses by Computer Simulation (시뮬레이션을 통한 주거공간 단독경보형감지기의 성능 분석)

  • Lim, Geun-Joo;Park, Sang-Cheon;Baek, Eun-Sun
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.29-35
    • /
    • 2020
  • This study was conducted to examine the performance in the space for a single alarm type detector installed in a single house. Three types of houses were used, including two types of one-story and two-story houses. A computer simulation program was used to predict the sound pressure level in response to the occurrence of an alarm sound in a residential space. The characteristics of the sound source applied to the simulation were directly measured and used as input data. As a result of simulation, it was found that the sound pressure level in the kitchen and living room generally met the standard when the alarm sound of the detector occurred. However, the sound pressure level in the bedroom was predicted to be at least 20 dB (A) lower than the American Fire Protection Association standard of 75 dB (A). Therefore, a plan should be prepared to maintain a sufficient sound level in the bedroom space inside the house, and efforts will be needed to ensure safe evacuation in case of fire by establishing relevant standards.

Analysis of Optical Properties of Fire Smoke and Non-fire Smoke for Reduction of Nuisance Alarm (장애경보 방지를 위한 연소 연기입자와 비연소 연기입자의 광 특성 분석)

  • Jee, Seung-Wook
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.10
    • /
    • pp.49-55
    • /
    • 2014
  • This paper is basic study for development of an advanced photoelectric type smoke detector that has high reliability by reducing the occurrence of nuisance alarms. This paper was attempted to distinguish optical characteristics of the typical fire smoke particle and non-fire smoke particle. According to UL 268 standards, three types of test fires (the paper, the wood and the flammable liquid) were used in this paper for measurement of the fire smoke particles, and the water vapor and the cigarette smoke that were known as the main cause of the nuisance alarms were also used for the non-fire smoke particles. A smoke detection chamber was created, which was equipped with one light source and several light sensors for enabling simultaneous detection of light extinction and scattering, respectively. This paper analyzes the optical characteristics of each smoke particle using this chamber.

Study on the Multi Functional Base Circuit for Fire Detector (다기능형 화재감지기 베이스에 관한 연구)

  • Baek Dong-Hyun;Park Sang-Tae;Lee Bog-Young;Lee Byung-Gon;Chun JI-Yong
    • Fire Science and Engineering
    • /
    • v.19 no.1 s.57
    • /
    • pp.99-103
    • /
    • 2005
  • This study is the mono signal detector and the multitype detector of mono signal On/Off circuit type. The multi functional base circuit focused on which is made of compatible with exiting fire detector base. The multi functional base circuit generates two fire signals at the same time, so it can link the existing fire alarm system with security system. The base circuit is easily able to be connected to exiting HA or OA facilities, having stability and reliability. As a result of the study, the multi functional base circuit has met the acceptance criteria of related national standards. Also, the security system of input signal can contribute to the smallest loss of lives and the property.