• Title/Summary/Keyword: Fire death

Search Result 105, Processing Time 0.029 seconds

An Epidemiological Observation of Fire Accident in Korea (화재사고(火災事故)(WHO-E 916)에 관(關)한 역학적관찰(疫學的觀察))

  • Lee, Chong-Dae;Han, Seong-Un;Bin, Soon-Duk;Chu, In-Ho
    • Journal of Preventive Medicine and Public Health
    • /
    • v.1 no.1
    • /
    • pp.43-49
    • /
    • 1968
  • Epidemiological and statistical observations were made of fire hazards that occurred during the past 18 years, 1948 to 1965. Injury and mortality rates for all ages were computed chronologically. For the years of 1955, 1961 and 1965, all fire accidents were epidemiologically analysed to draw characteristic patterns in relation to the seasonal and 24 hour distribution, causes and sites of accidents etc.. Fire hazards observed herein are the categorys E 916 of the International Classification of Causes of Death, 1955, and includes all accidents caused by fire and explosion of combustible materials. The following conclusion was made: 1. The average number of annual deaths due to fire was 183 and the number of the in jured due to the same cause was 335. The mortality rate per 100,000 population was 0.8 and the ratio of injuries per death was 1.83. 2. The casually rate including both the dead and injured was 5.0 per 100,000 in Seoul, the highest among the provinces and followed by 3.4 in Cheju -Do, 2.1 in Kangwon-Do, 1.7 in Kyunggi-Do accordingly. The other provinces had a range of 0.6 to 1.2. 3. The monthly distribution of fro accidents showed that the winter months, December through February, had more frequent accidents, while the summer season, June through August had less. The 24 hour distribution of accidents showed more cases from 12:00 to 18:00 and less from 4:00 to 10:00 hours. 4. The per cent distribution of causes of accidents showed; 90.0% for careless, 10.0% for arson. The cause of carelessness was further breakdown into; 15.0% for kitchen fire places, 13.8% for fire playing, 9,4% for electrical heating and wires, 8.3% for fuels, 6.3% for matches, 5.2% for ash dumps and the remaining for others. 5. The accidents as classified by place revealed that 56.8% of the total occurred at the common dwelling houses, 11.3 at various industrial workshops, 9.3% at the street shops and the remaining at the miscellaneous places.

  • PDF

Analysis on Home Accidents in Korea (가정 내 사고의 발생 실태 분석)

  • Lee Eui-Pyeong
    • Fire Science and Engineering
    • /
    • v.19 no.4 s.60
    • /
    • pp.7-17
    • /
    • 2005
  • On this paper, the actual conditions of home accidents by investigating rescue and emergency reports at fire stations in Gwangju Metropolitan city and annual report on the cause of death statistics in the National Statistical Office were analyzed, and actual conditions about home accidents in developed countries were studied. As a result, the following matters were confirmed: 1) Infants and older adults are the main victims of home accidents, especially the older adults. 2) The more older adults we have in our society, the more deaths caused by home accidents take place. 3) We must study the home accident of our society in the level of developed countries. And we must have the prevention policy about the home accidents.

Toxicological Study for Blood Cyanide and Carboxyhemoglobin Levels in the Fire- related Fatalities

  • Baeck, Seung-Kyung;Kim, Dong-Woo;Kim, Sun-Chun;Park, Woo-Yong;Jin, Kwang-Ho;Chung, Young-Ho;Park, Yun-Shin;Seo, Joong-Seok
    • Proceedings of the PSK Conference
    • /
    • 2003.04a
    • /
    • pp.170.2-170.2
    • /
    • 2003
  • The most common cause of death in fires is the inhalation of noxious gases rather than thermal injury. Carbon monoxide is well-known toxic component in fire atmospheres. However, the importance of hydrogen cyanide(HCN) as a toxic agent in the fire related fatalities(FRF) is under discussion. HCN is known to be produced in fires involving by the pyrolysis of polyacrylonitril (PAN) and other nitrogen-containing polymer. (omitted)

  • PDF

Analysis of the Absorbance Pattern of Postmortem Blood Sample Using Spectrometer (사후 혈액에서 흡광도 분석의 유용성에 관한 연구)

  • Na, Joo-Young;Park, Jong-Tae
    • The Korean Journal of Legal Medicine
    • /
    • v.42 no.4
    • /
    • pp.126-140
    • /
    • 2018
  • The diagnosis of cause of death (COD) or estimation of postmortem interval (PMI) is hard to perform using postmortem blood or other bodily fluids due to various biochemical changes that occur during the agonal phase or after death. To solve these problems, new paradigms and new analytical methods are needed. In this study, postmortem blood was fractionated with specific gravity 1.021, 1.029, 1.038, and 1.045, and the absorbance patterns of each sample of the 131 total cases (12 kinds of COD) were analyzed using a spectrometer. The absorbance was grouped into 9 patterns (ABS pattern 1 to 9) according to the wave length and the signal intensity. These patterns of postmortem blood were found to be distinctly different from the absorbance pattern of fresh blood. The analysis of ABS patterns is useful for the diagnosis of deaths due to acute or rapid bleeding, fire death, drowning and, in some cases, poisoning, but is not useful for the estimation of PMI.

Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location (선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성)

  • Han, Won-Hui;Cho, Dae-Hwan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.11 no.1 s.22
    • /
    • pp.53-59
    • /
    • 2005
  • It is very dongerous for ship‘s fire which occurs from navigating because of it will not be able to expect fire fighting from land so that handle with the oneself to control. Additionally, in the case of passenger ship is more serious for the reason of not only the property damage but also large life accident can be occurred continuously. When the fire occurs, the many smoke to occur simultaneously as well as the heat from combustion process and the poisonous smoke is brought the life damage as the death from suffocation The purpose of this study is to examine the smoke movement characteristics in the ship's indoor spaces with fire size and location An experimental study was carried out with two sized of fires and three typed of fire source locations. As the results, the smoke and heat diffusion characteristics Ms been showed the most quick rise curve in the case of comer type fire.

  • PDF

Smoke Movement Characteristics in the Ship's Indoor Spaces with Fire Size and Location (선박 실내공간에서 화재의 크기 및 위치에 따른 연기거동특성)

  • Han Won-Hui;Cho Dae-Hwan
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2005.05a
    • /
    • pp.167-173
    • /
    • 2005
  • It is very dangerous for ship‘s fire which occurs from navigating because of it will not be able to expect fire fighting from land so that handle with the oneself to control. Additionally, in the case of passenger ship is more serious for the reason of not only the properly damage but also large life accident can be occurred continuously. When the fire occurs, the many smoke to occur simultaneously as well as the heat from combustion process and the poisonous smoke is brought the life damage as the death from suffocation. The purpose of this study is to examine the smoke movement characteristics in the ship's indoor spaces with fire size and location An experimental study was carried out with two sized of fires and three typed of fire source locations. As the result of it, the smoke and heat diffusion characteristics has been showed the most quick rise curve in the case of comer type fire.

  • PDF

The development of the escape light control system (유도등 제어시스템의 개발)

  • Kim, Dong-Ook;Mun, Hyun-Wook;Lee, Ki-Yeon;Kim, Dong-Woo;Gil, Hyung-Jun;Kim, Hyang-Kon;Chung, Young-Sik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.6
    • /
    • pp.52-58
    • /
    • 2009
  • When a fire breaks out, it is frequent that large sized miserable death is happened by seriousness of poisonous gas and peculiarity of space because the building construction is recently more complex and diverse. So early countermeasure in preparation for evacuation escape linked directly with a loss of lives is pressing. Because escape light that mark fixing one-way of existing way is not efficiently extricated refugees from dangers when a fire breaks out, construction of system that can extricate refugees from dangers and suppress early a fire by grasping correctly fire point is required urgently. When a fire breaks out, all escape lights connected with fire sensor and reception group which have ill aiming in these point will lead people to safe emergency entrance of opposite direction of place that a fire is broken out after being calculated the direction and speed of flame and smoke. There is the purpose of my research in development of artificial intelligent directional escape light that can mark direction to most suitable pull-out and assist in early extinguishing a fire.

Performance Analysis and Improvement of National Fire Safety Code elements of Sprinkler System (스프링클러설비의 화재안전기준 요소의 성능분석 및 개선방안)

  • Oh, Taekhum;Lee, Jungil
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.4
    • /
    • pp.413-422
    • /
    • 2013
  • This study evaluated the fire safety code elements through analyze the loss of life when the fire occurred in the facility sprinklers installed evaluated. And through comparison with national fire safety code elements and standards of NFPA 13 in the United States, Was looking for ways to improve for Life and property damage. In the United States, in some cases, if you do not install the sprinkler are installed as per the fire death rate compared to 83 % lower. By contrast, If the domestic rate of 280 % fatalities were 3.37 times than the United States. This lack of fire performance were analyzed uniform occupancy classification, the amount of source of water supply, live not consider the density according to the standard number and the horizontal distance that causes the installation of sprinkler facilities were analyzed.

A Study on the Possibility of Ignition by Disposable Lighter (사례를 통한 화재사(火災死)의 이해)

  • Jae, J.J.;Lee, C.W.;Keon, H.S.;Son, J.B.;Lee, J.I.;Choi, D.M.
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.59-75
    • /
    • 2007
  • The causes of the fire casualties were the heat burns, contacted by flame, before the period of industrialization. According to the economic has been developed drastically since 1990, residing space has been become bigger and sophistication and interior finishing materials have been diversified. Therefore, the suffocation casualties, caused by inspiration of toxic combustion gases, have been more increased than the flame casualties in recently. Also, the arson casualties have been increasing with the increasing of insurance crime to take the Insurance money. According to National Emergency Management Agency announcement, 31,778 fires was occurred nationwide in 2006 and the total casualties were 2,180 occurred. 446 persons were died among them. Because the exact investigation of fire, occurred the death, is very especially important that civil and criminal cases will be happened. Therefore, we studied about the cause of fire, the place of origin, and the group of casualties age on the axies of fires, which were occurred recently. And the identification method of fire casualties, the human behavior characteristic, the flame casualties and the suffocation casualties at fire scene.

  • PDF

Review of Hazard Test of Combustion Gas and Exhaust Temperature of Acrylic Fire Protection Paint (아크릴계 내화도료 연소가스의 유해성 평가와 배기온도에 대한 고찰)

  • Jeon, Soo-Min;Kim, Jae-Jun
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.1-6
    • /
    • 2017
  • A fire resistance certification needs to be obtained before fire protection paint can be used in Korea. In the case of paint, the tests for certification are fire, gas hazard and bond strength. According to the hazard test standard of combustion gas, 16 mice are sacrificed every test. Therefore, there are ethical problems for the experimenter and legal problems for the laboratory. Accordingly, many alternatives are being assessed, such as combustion gas analysis, but they have not replaced animal testing yet. With gas hazard testing, the exhaust gas temperature can be measured. The property of the initial reaction of a specific fire paint can be characterized by this temperature. The purpose of this study was to consider the improvement point for a gas hazard test through comparative analysis of the exhaust temperature and the time of death of the mice.