• Title/Summary/Keyword: Fire damage

Search Result 1,102, Processing Time 0.038 seconds

Post-Fire Damage and Structural Performance Assessment of a Steel-Concrete Composite Bridge Superstructure Using Fluid-Structure Interaction Fire Analysis (FSI 화재해석을 이용한 강합성 교량 상부구조의 화재 후 손상 및 구조성능 평가)

  • Yun, Sung-Hwan;Gil, Heungbae
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.41 no.6
    • /
    • pp.627-635
    • /
    • 2021
  • The fire damage and structural performance of a steel-concrete composite superstructure under a highway bridge exposed to fire loading was evaluated. To enhance the accuracy and efficiency of the numerical analysis, a proposed fluid-structure interaction fire analysis method was implemented in Ansys Fluent and Ansys Mechanical. The temperature distribution and performance evaluation of the steel-concrete composite superstructure according to the vertical distance from the fire source to the bottom flange were evaluated using the proposed analysis method. From the analysis, the temperature of the concrete slab and the bottom flange of the steel-concrete composite superstructure exceeded the critical temperature. Also, when the vertical distance from the fire source was 13 m or greater, the fire damage of the steel-concrete composite superstructure was found to within a safe limit.

Research of the Fire to Minimization Damage Plan on High-rise Buildings (초고층 빌딩의 화재 피해 최소화 방안에 관한 연구)

  • Lee, Jung-Il;Lee, Geun-Tae
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.91-97
    • /
    • 2009
  • When the fire occur in a special place as High-rise building, find the solution from minimize the potential risk factors that caused to develop the human and materials damage by analysis. Through preventive activities are suppression of the fire occurrence or prevent the fire and extinguish the fire early. However, introduction of scientific suppression program could predict in advance the progress of the fire, or to block the path by using Intel Regent or Fire grid.

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

A Study on the Disaster Prevention Countermeasures of Tradition Buddhist Temple Cultural Treasure - A Case Study of the Fire Damage of the Naksansa which was due to Yangyang Forest Fire - (전통사찰문화재의 방재대책에 관한 연구 - 양양산불에 의한 낙산사의 화재피해사례를 통해 본 방재대책 -)

  • Back, Min-Ho;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.20 no.2 s.62
    • /
    • pp.64-71
    • /
    • 2006
  • After destruction of the Naksansa which was due to Yangyang forest fire, this the fundamental research about the disaster prevention countermeasures of tradition buddhist temple cultural treasure was performed. The present condition of tradition buddhist temple and related laws were investigated and the present damage condition of the Naksansa was surveyed. Also, the fire damage cases of tradition buddhist temple and the fire laws and regulations were investigated, and the survey about disaster prevention countermeasures was carried out. This research drew up the basic material about the disaster prevention countermeasures of traditional buddhist temple.

A Study on Ignition and Fire Risks of Electric Heat Wire (전기적 열선의 발화 및 화재 위험성에 관한 연구)

  • Min, Se-hong;Song, Byeong-jun
    • Journal of the Korea Safety Management & Science
    • /
    • v.17 no.4
    • /
    • pp.113-121
    • /
    • 2015
  • This study aims to examine the risk of electrical fire in places where electric heat wires are used. In general, the use of electric heating wires is becoming more common and prevalent in a bid to prevent increasing damage caused by freezing and bursting in residential water pipes, factory pipes and irrigation pipes in vinyl greenhouse and a variety of heat wire products are available in market with legal safety requirements imposed on them. However, the widespread use of anti-freezing burst heat wire products has caused increasing incidents of fire, which often fail to be incorporated into statistics due to quick onsite extinguishing and insignificant damage although damage is gradually on the rise. Against this backdrop, this study aims to look into the possibility of ignition caused by electric heat wires and the mechanism of how it turns into catching fire through overheat and short circuit tests for anti-freezing burst electrical heat wires (hereinafter called the 'heat wire') and expects to serve as the basis for further observations and analyses on the cause of fire and the process of ignition in a scientific manner.

An Impact Analysis and Prediction of Disaster on Forest Fire

  • Kim, Youn Su;Lee, Yeong Ju;Chang, In Hong
    • Journal of Integrative Natural Science
    • /
    • v.13 no.1
    • /
    • pp.34-40
    • /
    • 2020
  • This study aims to create a model for predicting the number of extinguishment manpower to put out forest fires by taking into account the climate, the situation, and the extent of the damage at the time of the forest fires. Past research has been approached to determine the cause of the forest fire or to predict the occurrence of a forest fire. How to deal with forest fires is also a very important part of how to deal with them, so predicting the number of extinguishment manpower is important. Therefore predicting the number of extinguishment manpower that have been put into the forest fire is something that can be presented as a new perspective. This study presents a model for predicting the number of extinguishment manpower inputs considering the scale of the damage with forest fire on a scale bigger than 0.1 ha as data based on the forest fire annual report(Korea Forest Service; KFS) from 2015 to 2018 using the moderated multiple regression analysis. As a result, weather factors and extinguished time considering the damage show that affect forest fire extinguishment manpower.

The Abstraction of Forest Fire Damage Area using Factor Analysis from the Satellite Image Data (위성영상 자료에서 요인분석에 의한 산불 피해 지역 추출)

  • Choi, Seung-Pil;Lee, Suk-Kum;Kim, Dong-Hee
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.14 no.1 s.35
    • /
    • pp.13-19
    • /
    • 2006
  • When investigating the damage of a forest fire, quite a few are depending on the naked eye observation. However, if the damage spreads to another area, it is easy to use the satellite images because it is hard to reach all the damaged areas on foot. From this research, we did a statistical interpretation of after fire using satellite image data to classify the damage on first and second factor analysis. As a result, it was more easier to classify the river's plants and ridges between rice fields that were in the forest fire damage area in the second observation then the first observation. Also, we could classify the area by areas that were damaged more or less using the second factor analysis. To verify this, we used the forest fire images collected from the satellite images and the actual survey data collected from spectral radiometer to see if these two datawere correlated and as a result we found out that they were highly involved.

  • PDF

A Study on the Proposal of Durability and Service Life of Fire Door in apartment house (공동주택 방화문의 내구성능 및 내용연수 제안에 관한 연구)

  • Kwon, Yeong-Jin;Kim, Yun-Seong;Jin, Seung-Hyeon
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.11a
    • /
    • pp.49-50
    • /
    • 2022
  • There are continuous cases of fire expansion due to fire door problems around the world, including the 2010 Shanghai Apartment Fire, the 2017 Grenfell Tower Fire in England, and the 2020 Ul-san Residential and Commercial Complex Fire. In order to prevent such fire damage, the country has strengthened the performance standards of fire doors, and recently, efforts have been made to ensure the best performance of fire doors by introducing a quality recognition system. Securing the performance of fire doors is a very important aspect. However, there is a concern that old fire doors may not function normally in the event of fire due to natural deterioration, corrosion, and damage during the use process, but countermeasures are insufficient. Therefore, from a management perspective, it is very important to maintain fire doors and secure an appropriate replacement time. Therefore, the purpose of this study is to determine whether the fire door has durability to prevent fire spread in the process of use through operation probability analysis and expert surveys, and to propose an appropriate useful life of the fire door.

  • PDF

Study on the Effective Method of Fire Protection Technology in Railway Tunnel Fire (철도터널 내화성능 기술개발을 위한 내화성능 확보방안에 관한 연구)

  • Park, Kyung-Hoon;Kim, Heung-Yeol;Kim, Hyung-Jun
    • Fire Science and Engineering
    • /
    • v.24 no.4
    • /
    • pp.86-91
    • /
    • 2010
  • In event of a tunnel fire, all kinds of equipment can be destroyed in high temperature that can exceed $1300^{\circ}C$, fatal structural demage can be caused by spalling of concrete structural elements. To make matters worse, there is a high possibility of the secondary damage which can lead to the collapse of the shear resisting structure. Accordingly, it is time that we developed the technology to counter fires in connection with the fire-resistant design of a tunnel structure. To secure the reliability of the fire-resistance performance of a tunnel structure, it is necessary to assess the fire's behavior on every structural element exposed to the fire as well as to calculate the tunnel fire intensity and the quantity of heat released. In this study, we drew out the fire damage range of each structural element of a tunnel and the minimum thickness of concrete cover for each fire-resistant material through some actual experiments of fire behavior on the structural elements of a tunnel.

The Way of operations and tactics for Disaster plan of High-rise Buildings (초고층 건물의 재난 발생 시 작전전술 방안)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.