• Title/Summary/Keyword: Fire casualties

Search Result 192, Processing Time 0.027 seconds

A Study on Accident Prediction Models for Chemical Accidents Using the Logistic Regression Analysis Model (로지스틱회귀분석 모델을 활용한 화학사고 사상사고 예측모형 개발 연구)

  • Lee, Tae-Hyung;Park, Choon-Hwa;Park, Hyo-Hyeon;Kwak, Dae-Hoon
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.72-79
    • /
    • 2019
  • Through this study, we developed a model for predicting chemical accidents lead to casualties. The model was derived from the logistic regression analysis model and applied to the variables affecting the accident. The accident data used in the model was analyzed by studying the statistics of past chemical accidents, and applying independent variables that were statistically significant through data analysis, such as the type of accident, cause, place of occurrence, status of casualties, and type of chemical accident that caused the casualties. A significance of p < 0.05 was applied. The model developed in this study is meaningful for the prevention of casualties caused by chemical accidents and the establishment of safety systems in the workplace. The analysis using the model found that the most influential factor in the occurrence of casualty in accidents was chemical explosions. Therefore, there is an urgent need to prepare countermeasures to prevent chemical accidents, specifically explosions, from occurring in the workplace.

The Effects of Activities and Working Conditions on Fire Accidents on Construction Sites

  • Yi, Kyoo-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.4
    • /
    • pp.383-389
    • /
    • 2020
  • Accidents on construction sites involving fires do not occur as often as accidents involving falls from height or collapses. However, once a fire accident occurs, there is a high risk of a large number of casualties. Fire on construction sites is affected by working conditions and the types of activities the construction workers are engaged in at the sites. This study aims to identify activities and working conditions at construction sites that are vulnerable to fire, and analyse how they correlate with each other and how they affect the causes and consequences of fire accidents at construction sties. I analysed 40 fire accident reports and listed the situations vulnerable to fire at construction sites considering direct causes, activities, and working conditions. The most dangerous combination of fire hazards can be the heating devices used during rest/sleep in the office/cabin/storage during cold weather. The next most hazardous combination can be sparks arising from painting, waterproofing, insulation, plumbing, or welding/melting work in an underground or confined space.

Improvement of fire protection equipment the opening of according to narrow the distance between buildings (건물 간 이격거리 협소에 따른 개구부 방화설비의 개선방안)

  • Oh, Taek-Hum;Park, Chan-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.1
    • /
    • pp.61-68
    • /
    • 2013
  • In the case of the fire to the exterior of the building through openings, the openings of the adjacent building are exposed to the risk of combustion expanding and factors that affect the combustion in the radiant heat and direct flame. Recent five years, fire of the adjacent building indicated that incidence of the 5,134(2.27%) among total 225,934 cases occurred The damage scale of fire expanded was lower than in a single building but casualties(5.46%) and property(25.0%) damage were higher. Therefore, this study provides to analyze the operating status for fire protection equipment of fire-preventing area in the Seoul and to apply measures to improve fire protection equipment according to narrow the distance between the building openings studied.

A Comparative Analysis on the building Fire Protection Standards of Korea and Japan (한·일 건축물 방화구획 기준 비교분석)

  • Shin, Yeoung-Deok;Han, Ji-Woo;Lee, Byeong-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.4-5
    • /
    • 2019
  • Smoke and fire spread throughout the building as a result of problems in the fire prevention section of Uijeongbu Apartment Fire in 2015 and Jecheon Sports Center Fire in 2017 in Korea, causing a number of casualties. It is believed that the fire compartment standards need to be reviewed as the fire in recent buildings continues to show problems. In this study, a comparative analysis was conducted on the fire prevention zone standard with Japan to improve the fire compartmente standard in Korea.

  • PDF

The Way of operations and tactics for Disaster plan of High-rise Buildings (초고층 건물의 재난 발생 시 작전전술 방안)

  • Lee, Jung-Il
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.3
    • /
    • pp.77-83
    • /
    • 2012
  • Recently, For the most efficient use of spaceis, high-rise buildings tend to increase. So it is with Korea, too. Besides, today high-rise buildings grows due to fire damage to life and property at large. In this study, Through analysis of domestic and foreign fire case and listen to the high-rise building fire managers, tenants, professionals advice, when the fire from the high-rise building, effective fire suppression tactics should we wish to research ways. In addition, we have used the car gondola was installed outside the fire suppression methods in studying. So that fire-fighting is a fire place can be reached quickly, many casualties and property damage, will be reduced.

A Development of Fire Training Simulator Based on Computational Fluid Dynamics Simulation (전산수치해석 기반 화재훈련 VR 시뮬레이터의 개발)

  • Cha, Moo-Hyun;Lee, Jai-Kyung;Park, Seong-Whan;Choi, Byung-Il
    • Korean Journal of Computational Design and Engineering
    • /
    • v.14 no.4
    • /
    • pp.271-280
    • /
    • 2009
  • An experience based training system concerning various fire situations which may result many casualties has been required to make rapid decision and improve the responsiveness. Recently, the necessity of virtual reality (VR) based training system which can replace a dangerous full-scale fire training and be easily adopted to the training or evaluation process is increasing. This study constructed tile virtual environment according to pre-defined scenarios, utilized the FDS(Fire Dynamics Simulator), three dimensional computational fire analysis program, to derive numerically simulated data on the propagation of fire. Finally, by visualizing the realistic fire and smoke behavior through virtual reality technique and implementing real-time interaction, we developed a VR-based fire training simulator. Also, in order to ensure the sense for tile real of a virtual world and reaI-time performance at the same time, we proposed appropriate data processing and space search algorithms, demonstrate d the value of proposed method through experiments.

A Study on the Analysis of Evacuation Risk by Building Application for Fire Safety (화재안전을 위한 건축물 용도별 피난리스크 분석에 관한 연구)

  • Jin, Seung-hyeon;Koo, In-Hyuk;Seo, Dong-Goo;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.05a
    • /
    • pp.164-165
    • /
    • 2021
  • In Korea, in the case of fire scenarios in performance design, it is assumed that the sprinkler is not working. In addition, it does not applicate various fire conditions. Therefore it is not enough that the accuracy about fire scenario. In foreign countries, reseach is being conducted to predict the casualities that can occur due to fire in the building space through statistical risk analysis. Also, research is consistently conducting for design that consider the sprinker probability of operation. Therefore, to analyze the fire risk of each building in Korea, the risk was analyzed using statistical data. As a result, the risk of casualties that can occur for each building use was analyzed as 0.6(persons/cases) for residential buildings, 0.25(persons/cases) for sales facilities, and 0.12(persons/cases) for buisiness facilities.

  • PDF

A Basic Study on the Fire Risk by Building Use based Growth Fire Statistics (성장화재통계 기반 건축물 용도별 화재위험도에 관한 기초연구)

  • Seo, Dong-Goo;Lee, Jong-Ho
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2020.06a
    • /
    • pp.218-219
    • /
    • 2020
  • The risk of a fire in a building is closely related to the usage of the building. In particular, all fires that occur in a building are not risky to safety of human life, and it is associated with the combustion area and the increase of total floor area of the building. Therefore, this study focused on safety of human life in terms of the statistics of fire with considering the aspect of growing fires and analyzed the statistical data of fire for 10 years. As for the analysis on fire, the time of occurrence by usages of buildings, frequency of occurrence and the ratio of casualties etc. were analyzed. It is expected that results of this study could be used for evaluations on a variety of parts in terms of design, construction and maintenance of buildings.

  • PDF

The Study of a Correlation between Heat Release and Smoke Production by Using Oxygen Consumption Calorimeter Up to 10 MW Facility (10MW급 까지의 산소소모율법 칼로리미터를 활용한 열방출률과 연기발생률의 상관성에 관한 연구)

  • Ryu, Sang-Hoon;Yoo, Yong-Ho;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.24 no.3
    • /
    • pp.58-65
    • /
    • 2010
  • The fire accidents having recently occurred are getting more and more larger and causing lots of damage in terms of property loss and casualties increase, so there is in need of technical fire safety development like comprehensive prevention solution in order to effectively prevent. Especially, the needing of new paradigm for advanced fire safe technology is gathering strength in high-rise modern building construction. Therefore, we want to find out on this paper what is a correlation between heat release rate measurement and smoke release volume by three parts of oxygen consumption calorimeter in bench scale calorimeter (cone calorimeter/ISO 5660/Avg.500Kw), Medium scale calorimeter (Room corner tester, Single burning Item/ISO 9750, EN 13823/Avg.3MW), and large scale calorimeter (Industry calorimeter/Avg. 10MW). Thus, Smoke detective of new paradigm devised by making use of a correlation between heat release and smoke production is to help reduce loss property and casualties. Ultimately, based on this theory, a new concept of fire alarm and evacuation system will be developed and expected to apply to a skyscraper.

A Comparative Analysis of Domestic and Foreign Standards to Improve the Performance of Zone Smoke Control System (거실 제연설비 성능 개선을 위한 국내·외 기준 비교 분석에 관한 연구)

  • Huh, Ye-Rim;Kim, Yoon-Seong;Kim, Hye-won;Jin, Seung-Hyeon;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2022.04a
    • /
    • pp.83-84
    • /
    • 2022
  • In Korea, smoke control measures through NFSC 501 are proposed to reduce human casualties caused by smoke in the event of a fire. However, as a result of investigating and analyzing domestic and foreign standards, it was found that domestic regulations do not set fire source, but simply set smoke emissions by floor area or height of smoke boundary. Foreign regulations set fire source. Therefore, it is judged that it is necessary to review whether the current domestic regulations can be applied in the event of an actual building fire. So, this paper aims to identify the differences in domestic and foreign standards through investigation and analysis of related standards for fire zone smoke control system in each country and use them as basic data to improve the performance of zone smoke control system.

  • PDF