• Title/Summary/Keyword: Fire accident

Search Result 703, Processing Time 0.02 seconds

Appropriate Smart Factory : Demonstration of Applicability to Industrial Safety (적정 스마트공장: 산업안전 기술로의 적용 가능성 실증)

  • Kwon, Kui-Kam;Jeong, Woo-Kyun;Kim, Hyungjung;Quan, Ying-Jun;Kim, Younggyun;Lee, Hyunsu;Park, Suyoung;Park, Sae-Jin;Hong, SungJin;Yun, Won-Jae;Jung, Guyeop;Lee, Gyu Wha;Ahn, Sung-Hoon
    • Journal of Appropriate Technology
    • /
    • v.7 no.2
    • /
    • pp.196-205
    • /
    • 2021
  • As industrial safety increases, various industrial accident prevention technologies using smart factory technology are being studied. However, small and medium enterprises (SMEs), which account for the majority of industrial accidents, are having difficulties in preventing industrial accidents by applying these smart factory technologies due to practical problems. In this study, customized monitoring and warning systems for each type of industrial accident were developed and applied to the actual field. Through this, we demonstrated industrial accident prevention technology through appropriate smart factory technology used by SMEs. A customized monitoring system using vision, current, temperature, and gas sensors was established for the four major disaster types: worker body access, short circuit and overcurrent, fire and burns due to high temperature, and emission of hazardous gas. In addition, a notification method suitable for each work environment was applied so that the monitored risk factors could be recognized quickly, and real-time data transmission and display enabled workers and managers to understand the disaster risk effectively. Through the application and demonstration of these appropriate smart factory technologies, the spread of these industrial safety technologies is to be discussed.

A Comparison of Residual Tensile Properties of GFRP Reinforcing Bar at High Temperature and after Exposure to High Temperature (고온과 고온노출 후 GFRP 보강근의 잔존인장성능 비교)

  • Kim, Seongdo;Moon, Doyoung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.35 no.1
    • /
    • pp.77-84
    • /
    • 2015
  • Tensile tests were conducted on the GFRP reinforcement exposed to high temperature. The exposure condition for this study was below $200^{\circ}C$ for about 3 minutes. This conditioning is minor compared with that presented in experimental program conducted by other researchers. The residual tensile strength and elastic modulus of GFRP reinforcing bars at high temperature and after exposure to high temperature were compared. In results, tensile properties were decreased at high temperatures, but those after exposure to high temperature were recovered to pre-heating level almost completely. These results could be valuable for evaluating GFRP reinforced structure damaged by fire accident.

A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors (정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구)

  • Choi, Chung-Seog
    • Journal of the Korean Society of Safety
    • /
    • v.28 no.2
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

A Study on Field Examinations and Interviews for Yeonpyeongdo Temporary Housing (연평도 임시주거시설 실태 및 면담조사 연구)

  • Moon, Jung-In;Song, Young-Hak;Wang, Woo-Chul;Lim, Seok-Ho
    • Journal of the Korean housing association
    • /
    • v.23 no.3
    • /
    • pp.21-28
    • /
    • 2012
  • The artillery fire accident in Yeonpyeong Island showed that the man-made disaster caused by the domestic political conditions as well as the conventional natural disaster can occur in Korea. Especially, it can be known that the whole community can be abandoned despite of a small scale of practical damage in residential district and the resulting large scale of refugees can be produced in the nation. This study investigated the real condition of temporary housing which has been provided at the Island. Firstly, in the theoretical review based on the literature study, the content on the background of temporary housing, the providing procedure of its concept, the status of supply, etc. has been considered. And it researched the current condition of the entire temporary housing through the questionnaire and interviews targeting the residents in the Island. So it purposed to make use of the results as a plan and design for future temporary housing against disaster.

Experiment and Simulation of Diffusion of Gas Released from the Relief Valve of a Gas Cylinder for a Portable Gas Range (압력 방출밸브를 장착한 이동식 부탄연소기용 부탄캔의 분출가스 확산 실험 및 해석)

  • Kang, Seung-Kyu;Choi, Kyung-Suhk;Yoon, Joon-Yong
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.1
    • /
    • pp.16-21
    • /
    • 2009
  • In the last five years, 91 accidents from portable gas ranges and non-refillable metallic gas cartridges have occurred. The gas cylinder installed with a relief valve was developed to prevent an explosive accident from the gas cartridge. In this study it was carried out to evaluate the safety of a gas cylinder mounted with a relief valve which can prevent an explosion. Under the real using condition and the extreme condition the gas cylinder is heated with an electric heater. Simultaneously, the operating pressure is checked and the suitability of releasing flux is evaluated. And the possibility of fire or explosion was tested when the gas was released from the relief valve at the real using condition. Using a numerical simulation method, the diffusion of butane gas released from a relief valve was visualized.

Qualitative Hazard Analysis for LNG Gas Stations Using K-PSR Method (K-PSR을 이용한 LNG 충진소에 대한 정성적 위험성평가)

  • Ko, Jae-Wook;Lee, Jae-Min;Yoo, Jin-Hwan
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.63-69
    • /
    • 2006
  • With the increased interest in reducing air pollution, supply of natural gas for gas vehicles is increasing. Thus, the number of establishments of LNG and CNG stations is increasing as well. However, due to major gas accidents such as the fire and explosion accident of a Bucheon LPG station in 1998, it is difficult to establish a new station. In this research, we conducted qualitative hazard analysis fer LCNG/LNG multi-station by using the K-PSR method and proposed recommendations for hazard mitigation.

  • PDF

A Study on the Overpressure Estimation of BLEVE (BLEVE로 인한 과압 예측에 관한 연구)

  • Kim In-Tae;Kim In-Won;Song Hee-Oeul
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.1 s.9
    • /
    • pp.69-76
    • /
    • 2000
  • Explosion Quantities and flashing mass resulting from the variation of temperature are calculated by a computer program, BLEVE ESTIMATOR, to carry out the risk assessment of BLEVE. The damages caused by the BLEVE are estimated under the explosion of the simulation condition similar to the Puchun LP gas station accident, and the results are compared with the commercial program SAFER of Dupont CO. Explosion quantities and flashing mass increase exponentially with the increase of explosion temperature. These values for propane are relatively higher than those for n-butane. In conditions of higher vessel temperature, vessel pressure, and liquid ratio of containment, higher overpressures are calculated.

  • PDF

Study on the Electrical Safety Management Method through the Electrical Characteristic Analysis of LED Lamps (LED 램프의 특성 분석을 통한 전기안전 관리 방안에 관한 연구)

  • Lee, Ki-Yeon;Moon, Hyun-Wook;Kim, Dong-Woo;Lim, Young-Bea;Ryu, In-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.11
    • /
    • pp.1931-1936
    • /
    • 2016
  • In this paper, we analyzed causes of accidents that recently increased in the illegal and defective LED lamps. They were analyzed by the electrical characteristics calculation and reappearance experiments. The causes of the accidents were analyzed from the circuit affected by the variation of voltage, current and power by harmonics. We drew a conclusion for electrical safety in illegal or degraded LED lamps from the analysis result. The management factors for electrical safety in LED lamps were harmonics, reactive power and power factor. It is possible to secure the electrical safety through monitoring of power factor in failure products and available in smart meters or smart distribution boards.

A Systems Engineering Approach to Development of a Worker's Location Monitoring System in Ship and Offshore Plant (선박 및 해양플랜트 환경에서 작업자 위치 모니터링 시스템 개발을 위한 시스템엔지니어링 접근 방법)

  • Park, Jong Hee;Kim, Han June;Yoon, Jae Jun;Kim, Hyoung Min;Hong, Dae Geun
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.16 no.1
    • /
    • pp.68-77
    • /
    • 2020
  • The shipbuilding and offshore industry is a large and complex assembly industry, which causes many safety accidents. The major accidents in the shipbuilding and offshore industry workplaces are stenosis, falling objects, dust, fire, explosions, and gas poisoning. The accident by worker in this industry mainly has three factors: frequent movement, narrow work space, and increased use of subcontractors. To control these factors, it is necessary to monitor the worker's location and work status. In this paper, a worker location monitoring system using inaudible sound wave was designd that can be used in environments with many metal barriers. The process included deriving stakeholder requirements, transforming to system requirements, designing system architecture, and developing prototype. The prototype was validated by third-party testing agency. As a result, it satisfied the designed performance and verified its feasibility.

A Study on the Life Time of RCD in Coastal Area (해안지역에서의 저압용 누전차단기 교체주기 연구)

  • Kim, Chong-Min;Choi, Myeong-Il;Shong, Kil-Mok;Seo, Jung-Youl;Shin, Jin-Yong;Kim, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.85-92
    • /
    • 2011
  • The role of RCDs(Residual Current Protective Device) that are installed before the load is very important for preventing electric shock and electrical fire. However, although fault rate of RCD is increasing due to deterioration and long period usage, the RCD is permanently used without a checking of performance evaluation and it causes the electrical accident. In this paper, the amount of airborne chloride is researched in domestic costal area and the accelerated life test is conducted using a salt water spray tester in order to decide the life time of RCD. Aa a result of an accelerated life test, the MTTF(Mean Time To Failure) of RCD is 110.81 hours and B10 life time of RCD is 45.81 hours for the all samples. when an accelerated life test result is applied to within 2 km costal area, the life time of RCD is predicted about 5 years.