• 제목/요약/키워드: Fire Type

검색결과 1,095건 처리시간 0.028초

조선시대 동해안지역 연변봉수에 관한 연구 (A Study on the Border Signal-fire In Eastern Sea)

  • 이철영;김성철
    • 건축역사연구
    • /
    • 제17권2호
    • /
    • pp.47-66
    • /
    • 2008
  • This research was to analyze the border signal-fire which is the main facility of military protective duty for safety of sea side in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, half-circle, oval, round-rectangular. The majorities were circle type in eastern area. 2. Plan configuration of signal-fire stand which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of signal-fire stand was about $2{\sim}3m$. The diameter of signal-fire stand was $8{\sim}10m$. Building base that protect ground moisture and infilteration of rainfall was found in 9 border singal-fire, the height of it was about $0.3m{\sim}2.5m$. 3. Trench was mainly circle type and average width was $3{\sim}4m$. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 4. The height of protective wall remained until present was about 1m, the depth was about average 2.5m. 5. The storage of border signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the signal-fire stand.

  • PDF

Loop형 스프링클러 설비의 수리계산 방법에 대한 제시 (A Presentation on the Manual Hydraulic Calculation Method of the Loop Type Fire Sprinkler System)

  • 정기신
    • 한국화재소방학회논문지
    • /
    • 제29권1호
    • /
    • pp.73-79
    • /
    • 2015
  • 스프링클러 설비의 설계방법은 크게 3가지로 분류한다. 가지관을 서로 연결하여 사다리형태로 배관을 설치하는 Grid형과 가지관은 연결하지 않고 교차배관만을 연결하는 Loop형 그리고 가장 일반적으로 사용되는 Tree형이 있다. 이 중 Grid형은 아주 간단한 것을 제외하고는 컴퓨터프로그램으로 마찰손실을 계산하여야 하지만 Loop형의 경우는 프로그램의 도움 없이 설계자가 직접 계산하여 마찰손실에 따른 필요압력과 소요유량을 산출할 수 있다. Loop형 설비의 경우 소화수 공급이 2방향으로 분리되어 마찰손실이 작아지고 헤드간 방출압력의 차이가 Tree형보다 작게 되어 살수분포가 우수하게 되며 작은 마찰손실에 의한 소구경의 배관을 사용하여 자재비와 인건비가 절감되므로 Loop형에 의한 스프링클러의 설계가 Tree형 설비에 비해 성능과 경제성에서 우수한 설계 방법이다. 하지만 Loop형 설비의 설계는 설계방법이 잘 알려져 있지 않아 거의 이루어지지 않고 있다. 본 논문에서는 Tree형 보다 우수한 Loop형 설비의 설계방법을 설명하여 많은 설계자가 성능과 경제면에서 우수한 Loop형 설계를 쉽게, 널리 사용하게 하고자 하였다.

효과적인 소방활동을 위한 지하주차장 스프링클러설비 송수배관 연결방식의 개선에 관한 연구 (A Study on Improvement of Connection Method of Underground Parking Lot SP Equipment Water Supply Pipe for Effective Fire Activities)

  • 손개성;최지훈;최돈묵
    • 대한안전경영과학회지
    • /
    • 제17권4호
    • /
    • pp.161-169
    • /
    • 2015
  • A fire sprinkler system is very important to extinguish fire in the building. The sprinkler system initiates sprinkler discharge if the detection system identifies a developing fire and opens the pre-action valve. However, pre-action fire sprinkler systems mainly installed in the underground parking lot at the apartment complex do not properly operate at fire if the connection type of fire sprinkler systems does not properly installed and operated. This study identified the relationship between fire dispersion & damage and the connection type of water supply in the sprinkler system from many fire cases at the apartment complex in South Korea. In addition, this study also identified the water supply differences and characteristics between South Korea and foreign countries. The main purpose of this study is also to improve the water connection types in the sprinkler system that can reduce the potential failures of pre-action valve operation through electrical signal system. The study also suggests the improvement plan for water connection types in pre-action fire sprinkler system that can minimize potential failure of pre-action fire sprinkler system. The suggestions for revising the fire safe standard in South Korea includes letting the water supply pipe of sprinkler system water inlet connect to the second side of pre-action valve and the water flow device that can minimize potential failure of sprinkler system.

건조일체형 드럼세탁기의 화재위험성에 관한 실험연구 (A Experimental Study on the Fire Hazards in Drum-Type Electric Washing Machine)

  • 홍성호
    • 전기학회논문지P
    • /
    • 제57권3호
    • /
    • pp.328-331
    • /
    • 2008
  • This study presents on the analysis fire hazards of drum type electric washing machine. In order to analyze fire hazards fire experiment is conducted. The fire experiment is conducted to simulate under the normal condition and abnormal condition. The experiment under the abnormal condition is simulated in safety device failure, situation of accumulated dust and tracking phenomenon caused by humidity. The results show that fire hazard is high at the abnormal condition. In this paper, we suggest to use the safety device of low operating temperature in electric washing machine for reducing fire hazard.

랙크식 창고 화재의 수직 확산 방지를 위한 수평차단막과 In-Rack 스프링클러 적용에 관한 실험연구 (An Experimental Study on the Application of Horizontal Barrier and In-Rack Sprinklers to Prevent Vertical Spread of Rack-type Warehouse Fires)

  • 박문우;홍성호;최기옥;최돈묵;김수진
    • 한국안전학회지
    • /
    • 제34권5호
    • /
    • pp.15-21
    • /
    • 2019
  • A rack-type warehouse has the advantage of storing a large amount in a small area by loading goods vertically. But in terms of fire risk, the fire load is very high, which can cause massive damage in the event of a fire. In the United States, research has been actively conducted to minimize the spread of vertical fires, and relevant standards have been established and operated. In Korea, research and related standards are insufficient to prevent the vertical spread of rack-type warehouse fires. In this study, an experimental study was conducted to prevent the vertical spread of a rack-type warehouse fire using a horizontal barrier and in-rack sprinklers. As a result of the test, the horizontal barrier considering the continuous flame prevented the vertical spread of the flame for a certain time. However, the horizontal barrier with continuous flame did not show the effect of preventing continuous flame. The combination of the horizontal barrier and the in-rack sprinkler prevented the vertical spread of fire effectively. In addition, the heat collecting effect through the horizontal barrier was shown and helped the early operation of the in-rack sprinklers.

Designing method for fire safety of steel box bridge girders

  • Li, Xuyang;Zhang, Gang;Kodur, Venkatesh;He, Shuanhai;Huang, Qiao
    • Steel and Composite Structures
    • /
    • 제38권6호
    • /
    • pp.657-670
    • /
    • 2021
  • This paper presents a designing method for enhancing fire resistance of steel box bridge girders (closed steel box bridge girder supporting a thin concrete slab) through taking into account such parameters namely; fire severity, type of longitudinal stiffeners (I, L, and T shaped), and number of longitudinal stiffeners. A validated 3-D finite element model, developed through the computer program ANSYS, is utilized to go over the fire response of a typical steel box bridge girder using the transient thermo-structural analysis method. Results from the numerical analysis show that fire severity and type of longitudinal stiffeners welded on bottom flange have significant influence on fire resistance of steel box bridge girders. T shaped longitudinal stiffeners applied on bottom flange can highly prevent collapse of steel box bridge girders towards the end of fire exposure. Increase of longitudinal stiffeners on bottom flange and web can slightly enhance fire resistance of steel box bridge girders. Rate of deflection-based criterion can be reliable to evaluate fire resistance of steel box bridge girders in most fire exposure cases. Thus, T shaped longitudinal stiffeners on bottom flange incorporated into bridge fire-resistance design can significantly enhance fire resistance of steel box bridge girders.

조선시대 내지봉수에 관한 연구 (A Study on the Inland Signal-fire in Chosun Dynasty)

  • 윤재웅;이철영
    • 건축역사연구
    • /
    • 제18권6호
    • /
    • pp.47-64
    • /
    • 2009
  • This research was to analyze the inland signal-fire which is the main facility of military protective duty for safety of land in chosun dynasty. The results of this research were described separately as follows. 1. Five types of site plan of signal-fire were observed, which is circle, oval, rectangular, indeterminate form. The majorities were oval type. 2. Plan configuration of brazier which is separated with circle, rectangular type roughly was constructed with circle type generally. The height of brazier was about 3~4.5m. The diameter of brazier was 1.5~2.5m. Building base that protect ground moisture and infilteration of rainfall was found in 5 inland singal-fire, the height of it was about 0.3m~2.5m. 3. The heigh to protective wall remained until present was about 1m, the depth was about average 1.2m. 4. Entrance was mainly stairs or open type and average width was 1.0~1.2m. However the depth was almost observed as 1m, originally, it was estimated it has more depth. 5. The storage of inland signal-fire has rectangular dimension, several types of $1.8{\times}1.2m{\sim}5.7{\times}4.4m$, square(間) of $1{\times}1{\sim}2{\times}1$. The building material was stone and located below or near the brazier.

  • PDF

제조 사업장의 환풍기 화재위험성 조사 (The Survey of Fire Hazard of Fan in Manufacturing Industries)

  • 김성삼
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.21-29
    • /
    • 2013
  • The short circuit and overload is presented by main cause of electrical fire. However, 85% of the fan directly connected the outlet box without switch in total 110 fans as a research in manufacturing industries. In installation direction of vertical type fans which was placed on the horizontal surface, only 39 vertical type fans were placed on vertical surface and 71 fans were placed on the horizontal type. The installation direction of the fans warns of the risk of the fire hazard due to the motor stall to the user manual of the maker. However, it is the representative nonconformity example of construction which the people or builder disregards. In addition, the condition of ground connection with the earth leakage prevention was investigated in grounding of 5 fans, non-grounding of 105 fans. The double insulation structure is generally used for small fan and it can't connect ground wire as electric plug of non-grounding type. However, industrial iron fan needs ground wire for electric leakage and to protect against electric shock.

대심도 지하철 승강장의 종류별 연기전파특성 비교고찰 (THE COMPARISON ON THE CHARACTERISTIC OF THE FIRE DRIVEN SMOKE-FLOW FOR THE PLATFORM TYPES IN THE DEEPLY UNDERGROUND SUBWAY STATION)

  • 김학범;장용준;이덕희;정우성;황현배
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.505-507
    • /
    • 2010
  • 본 논문에서는 대심도 지하철역사의 승강장 종류에 따라 화재시 연기의 전파특성을 비교하였다. 본 연구에서 비교 대상역사로서 상대식 승강장은 서울 숭실대입구역사(47m)로, 섬식은 부산 만덕지하역사(65m)를 선정하여 각 역사에 대하여 화재전산모사를 수행하였다. 해석을 통하여 화재의 연기전파특성을 파악하였으며, 그 결과를 이용하여 각 승강장 종류별로 대심도 지하역사의 방재대책을 세우고자 한다.

  • PDF

The Impact of Building Types on Fire Damage by Month

  • Yi, Kyoo-Jin
    • 한국건축시공학회지
    • /
    • 제19권6호
    • /
    • pp.567-575
    • /
    • 2019
  • Statistics show that while the number of fires has decreased over the last decade, losses of human life and economic property due to fire have increased. Moreover, the number of large-scale fires that have occurred in recent years has resulted in heightened public anxiety. This study aims to identify a specific period of the year most vulnerable to fire, and fire trends, such as damage of fire to humans, to the economy, and different building types. For this purpose, we analyzed human and economic damages using statistics related to fire from 2007 to 2017 and provided a monthly distribution of fire damages both to humans and to the economy by building type. We also identified the relationship between the human damage and the economy damage, and compared the economic losses per casualty by building type. The human damage in residential buildings occupied the highest portion, whereas the economic damage of industrial buildings represented more than a half of all economic damage due to fire. The economic damage per casualty was shown highest for industrial buildings and has also increased rapidly in recent years.