• 제목/요약/키워드: Fire Simulation

검색결과 1,011건 처리시간 0.028초

건축물 밀집지구의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구 (A Study on the Analysis of Simulation for Fire Safety Diagnosis in Building Congested Area)

  • 구인혁;윤웅기;김봉찬;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 추계 학술논문 발표대회
    • /
    • pp.226-227
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

목조건물 밀집 지역의 화재위험성 평가를 위한 시뮬레이션 해석에 관한 연구 (A Study on the Analysis of Simulation for Fire Safety Diagnosis in Wooden Building Congested Area)

  • 구인혁;김봉찬;서동구;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2013년도 춘계 학술논문 발표대회
    • /
    • pp.87-88
    • /
    • 2013
  • Korea rapidly arranged urbanization and overpopulation with high growth of economy and all kinds of decrepit facilities are scattered all over the downtown. If there is a strong wind in fire, fire is rapidly increased by various fire spread factors. And Korea cannot build prediction model of urban fire combustion phenomena because there is no studies that physically explains the suitable flame phenomena for its real state. In this study, based on the Japanese Urban fire simulation to target the wooden building congested Area and suitability of fire risk assessment were reviewed.

  • PDF

Numerical analysis to determine fire suppression time for multiple water mist nozzles in a large fire test compartment

  • Ha, Gaghyeon;Shin, Weon Gyu;Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • 제53권4호
    • /
    • pp.1157-1166
    • /
    • 2021
  • In this study, a numerical sensitivity analysis was performed to determine the fire suppression time for a large number of water mist nozzles in a large fire compartment. Fire simulations were performed using FDS (Fire dynamics simulator) 6.5.2 under the same condition as the test scenario 5 of the International Maritime Organization (IMO) 1165 test protocol. The sensitivities of input parameters including cell size, extinguishing coefficient (EC), droplets per second (DPS), and peak heat release rate (HRR) of fuel were investigated in terms of the normalized HRR and temperature distribution in the compartment. A new method of determining the fire suppression time using FDS simulation was developed, based on the concept of the cut-off time by cut-off value (COV) of the heat release rate per unit volume (HRRPUV) and the cooling time by the HRR cooling time criteria value (CTCV). In addition, a method was developed to determine the average EC value for the simulation input, using the cooling time and cut-off time.

FFM과 FDS를 이용한 화재 대피 시뮬레이션 (Fire Evacuation Simulation Using FFM and FDS)

  • 이재영;이민혁;전철민
    • 한국지리정보학회지
    • /
    • 제21권2호
    • /
    • pp.56-67
    • /
    • 2018
  • 일반적으로 화재 및 대피에 대한 안전성을 진단하기 위해 화재 시뮬레이터와 대피 시뮬레이터를 독립적으로 활용하고 있다. 이 방식은 화재 확산을 고려한 보행자의 움직임이 반영되어 있지 않기 때문에 높은 정확도의 안전성 진단을 기대하기 어렵다. 이에 본 연구에서는 화재 확산을 고려한 보행자의 움직임을 묘사할 수 있는 화재 대피 시뮬레이션 기법을 제안한다. 본 연구에서 제안하는 시뮬레이션 기법은 FDS(Fire Dynamics Simulator)의 화재 확산 데이터를 보행모델 FFM(Floor Field Model)에 반영하여, 보행자가 화재를 인지하고 이를 바탕으로 우회하여 안전한 경로로 대피하는 상황을 묘사한다. 연구 범위는 FDS와 FFM 간의 데이터 연동 및 화재 확산을 고려한 FFM 개발로 구성되며, 제안한 방법론의 실험은 대피 시뮬레이터 EgresSIM을 이용하여 진행하였다. 시뮬레이션 결과에서는 화재의 유무에 따른 출구별 대피인원 변화가 나타났으며, 이에 따른 출구별 대피시간 증감과 병목현상의 심화를 확인할 수 있었다.

주거공간 에어로 시스템 배치에 관한 화재시뮬레이션 연구 (A Study on Fire Dynamics Simulation on the Arrangement of Aero System in the Residential)

  • 최두찬;고민혁;이두희;박계원;최정민;이용권;김길남;선경수
    • 한국재난정보학회 논문집
    • /
    • 제17권4호
    • /
    • pp.890-896
    • /
    • 2021
  • 연구목적: '에어로 시스템'이란 제품을 개발하였으며, 화재 특성상 신속한 감지가 무엇보다 중요함으로 개발하고 있는 제품을 주거 공간 어느 지점에 배치를 하였을 때 신속하게 감지를 할 수 있는지 화재 시뮬레이션을 통해 확인하고자 하였다. 연구방법: 18평형의 주거 공간에서 화재시뮬레이션을 수행하였으며, 화재 환경이 빨리 노출되는 지점을 찾고자 침실, 거실 별로 측정점을 높이 0.6m, 1.5m 지점으로 설치하여 빨리 감지 되는 지점을 확인하였다. 연구결과: 대부분 1.5m 지점으로 설정한 온도 및 일산화탄소 센서가 기준 치에 빨리 감지 되는 지점을 확인하였다. 결론: 소화모듈과 AQI모듈이 분리된 제품을 벽에 부착형으로 설치할 경우 화재 감지가 상대적으로 빠른 것으로 확인되었다.

CFD 화재 시뮬레이션을 이용한 여객선 제연설비의 성능기반 설계 사례 (A Performance-based Design Example of Smoke Extraction System Using CFD Fire Simulation)

  • 이정무;김성훈;이성근
    • 대한조선학회논문집
    • /
    • 제47권3호
    • /
    • pp.454-461
    • /
    • 2010
  • The new SOLAS regulation permits the alternative design approach for the approval of designs which deviate from those where prescriptive rules apply. The new approach is being promoted by recent advances of noble designs such as those employing large public spaces in passenger ships. From the respect of fire safety, it is needed to show that the level of safety of new design is equivalent to what can be achieved from the prescriptive rules where the fire simulation is regarded to be the essential tool. This paper provides an overview of the process of performance-based design of the smoke extraction system in a cafeteria of a ROPAX. FDS, a CFD fire simulation software is used to show that the field-model software can improve the fire safety over what are expected from prescriptive rule sets or zone-model application.

송전용 폴리머 애자에 대한 산불 영향 평가 (The Influence of Forest Fire on the Polymer Insulator for Transmission Lines)

  • 최인혁;이동일;이철호;강병규;이원교;박준호
    • 한국전기전자재료학회논문지
    • /
    • 제20권9호
    • /
    • pp.787-792
    • /
    • 2007
  • To understand the effects of forest fires on polymer insulators for transmission lines, the forest fire simulation tests were performed with polymer and porcelain insulators at Gochang testing center. These tests consisted of energizing 90 kV at line-to-ground voltage of 154 kV lines and open flame rising up to $600-630^{\circ}C$ as being measured at insulator surface. Mechanical and electrical characteristics such as specific mechanical load, leakage current, low frequency dry flashover voltage and impulse flashover voltage were analyzed for the polymer insulators before, during and after simulation tests compared with porcelain insulators. At the end of fire simulation tests, there was no detrimental deterioration of any insulators. All insulators passed the criteria of KEPCO specification. This study showed that forest fire simulation had no impact on polymer insulators.

화재 발생 지하철 역사에서의 여객 대피 해석에 관한 연구 (A Numerical Study on Passengers' Evacuation in a subway station in case of Fire Occurrence)

  • 김치겸;이성원;허남건;남성원
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.142-147
    • /
    • 2009
  • In the present study, a numerical simulation of passenger evacuation in a subway station was performed. Algorithm for passenger flow analysis based on DEM(Discrete Element Method) has been improved to simulate passenger flow in detailed geometry. The effect of grid density was assessed in the present study to show the advantage of using finer grid in the simulation. The method of coupling passenger flow and fire simulation has also been investigated to analyze passenger evacuation flow under fire. In this method the CO distributions in the subway station was used to assess fire hazards of passenger by means of FED(Fractional Effective Dose) model. Using the coupled algorithm a simulation for passenger evacuation flow and fire analysis were performed simultaneously in the simplified subway station. This algorithm could be used in the design of subway station for the purpose of passengers' safety in case of fire.

  • PDF

선박기관구역 미분무수 소화설비 화재진압 성능 평가 (The Assessment of Fire Suppression Capability of Water-Mist System for Machinery Engine Room)

  • 최병일;한용식;오창보;김명배;김창
    • 한국화재소방학회논문지
    • /
    • 제21권2호
    • /
    • pp.111-117
    • /
    • 2007
  • IMO MSC/circ. 1165 규정에 따라 미분무수를 이용한 선박 기관구역($20m{\times}15m{\times}10m$)에서의 실물화재 소화실험을 수행하였다. K-factor 2.4인 노즐을 사용하였으며 작동압력은 80 bar이다. 미분무수의 화재진압 특성을 수치적으로 예측하기 위하여 FDS를 사용하여 실험과 같은 조건에서의 전산시뮬레이션을 수행하였다. 전산 시뮬레이션 결과 화재 전산 시뮬레이션 기법이 화재소화시간 예측에는 한계를 가지나, IMO MSC/circ. 1165 규정의 공간 내 온도분포 제어 성능의 예측을 위해서 유용하게 활용될 수 있음을 보였다.

명중확률 개선 및 효율적인 대화력전 수행방안 (An Improvement of Hit-probability and an Efficient Counter-fire Execution)

  • 김세용;이재영
    • 한국시뮬레이션학회논문지
    • /
    • 제17권4호
    • /
    • pp.143-152
    • /
    • 2008
  • 미래전에 있어서, 전투 초기단계의 대화력전 능력은 적을 무력화 시키는데 핵심역할을 수행한다. 본 논문에서는 효율적인 대화력전 수행방안을 제안하였다. 이를 위해, CEP를 사용한 명중확률을 산출한 후 대화력전 작전시 활용 가능한 새로운 사격제원 계산에 적용하였다. 새로운 표적제원의 타당성 검증을 위해 MANA 모델을 사용하여 시뮬레이션을 수행하였다. UAV 운용여부 등을 포함한 다양한 시나리오 상황 하에서 시뮬레이션 수행 결과, 새로운 사격제원산출 방법을 사용한 명중률이 기존의 BTCS 사격제원에 의한 명중률 보다 우수한 것으로 나타났다.

  • PDF