• Title/Summary/Keyword: Fire Safety Test

Search Result 541, Processing Time 0.03 seconds

Effect of External Thermal Insulation Composite System with a Non-combustible Calcium Silicate Based Mineral on The Mitigation for Reducing Fast Spread of Flame (불연성 무기 단열재를 화재확산 방지구조로 적용한 외단열 마감시스템의 화재성능)

  • Lee, Jong-Chan;Park, Jong-Chul;Song, Hun
    • Journal of the Korea Institute of Building Construction
    • /
    • v.16 no.5
    • /
    • pp.397-403
    • /
    • 2016
  • As a building energy saving standard strengthened, The number of building installed external thermal insulation composite system(ETICS) using EPS insulation increased. But frequent fire accident in the buildings installed EIFS using EPS led to strengthening of building fire safety regulation. This study is for fire property of EPS ETICS reinforced with noncombustible calcium silicate-based mineral insulation as a fire spread prevention structure(FSPS). Fire test for large scale wall by ISO 13785-2 was applied and results showed EPS EIFS with FSPS got 3~8 times superior fire safety than normal EIFS by visual investigation. Temperature and heat flux measurement results, which data of upside of specimen were lower than downside, also supported fire safety of EIFS with FSPS.

A Study on the Fire Risk Assessment of Combustible Exhaust Duct-fume (가연성 배기덕트-흄 화재위험성 평가에 관한 연구)

  • Yoon, Yeo-Song;Lee, Young-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.1
    • /
    • pp.32-37
    • /
    • 2010
  • When back-out & firing Process applies heat, hume is piled up in exhaust duct by organic compound and it have high dangerousness. There by, the process is happening a lot of damage that is exhaust duct fire. However we do not have certain fire dangerousness estimation and digestion countermeasure. So we need preventive measure. Back-out & firing is a process which has fine structure, electrical and mechanical characteristics, such as firing kiln and back-out kiln which has pipe line and box type. The box oven is made of heating coil, fan motor and control panel. Back-out & firing process has air circulation institution of quick ventilation type. When we operate this process for long time, fire can break out easily. Duct is made by zinc shredder. If fire breaks out in duct inside, fire by deposit fume can be dispersed easily. Accordinglym, This project estimate danger for back-out & firing process exhaust duct through real fire test. And there is purpose of study to establish preventive measure.

Experimental studies on the behaviour of headed shear studs for composite beams in fire

  • Lim, Ohk Kun;Choi, Sengkwan;Kang, Sungwook;Kwon, Minjae;Choi, J. Yoon
    • Steel and Composite Structures
    • /
    • v.32 no.6
    • /
    • pp.743-752
    • /
    • 2019
  • Steel and concrete composite structures are commonly applied in multi-story buildings as they maximise the material strength through composite action. Despite the popularity of employing a trapezoidal deck slab, limited experimental data are available under elevated temperatures. The behaviour of the headed shear stud embedded in a transverse trapezoidal deck and solid slab was investigated at both ambient and fire conditions. Twelve push-out tests were conducted according to the ISO 834 standard fire utilising a customised electric furnace. A stud shearing failure was observed in the solid slab specimen, whereas the failure mode was changed from a concrete-dominated failure to the stud shearing in the transverse deck specimen with an increase in temperature. Comparisons between the experimental observations and design requirements are presented. The Eurocode design guidance on the transverse deck slab gives a highly conservative estimate for shear resistance. A new design formula was proposed to determine the capacity of the shear connection regardless of the slab type when the stud shearing occurs at high temperatures.

A Study on the Characteristics of Smoke Control using PIV in Tunnel Fires (터널내 화재시 PIV를 이용한 연기제어 특성에 관한 연구)

  • Ko, Jae-Woong;Kim, Jong-Yoon;Seo, Tae-Beom;Lim, Kyung-Bum;Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.5 s.77
    • /
    • pp.6-11
    • /
    • 2006
  • This study aims to measure a smoke density and velocity by using the PIV method in case a fire occurs in tunnels. By doing so, this will estimate a critical velocity, examine its appropriateness, and present the basic materials necessary for designing a smoke control equipment. For this study, a visualization test was conducted based on the 1/20 miniature of a real tunnel according to the Froude scaling. As a part of basic experiments, a correlation between smoke density and brightness was analyzed here, and a critical velocity was estimated on the condition that a fire breaks out in tunnels. As a result, this study finds that there is a correlation between smoke density and brightness within a range of 100% to 30% transmittance, from which a quantitative smoke density can be obtained. The study also suggests that a critical velocity calculated from the Kennedy formula shows about 10% difference from that estimated in the test.

Calculation of Uncertainty in Measuring Heat Release Rate in Room Corner Test (룸코너 시험기의 발열량 측정에 대한 불확도 산정)

  • Noh, Kwang-Chul;Kim, Chi-Hoon;Lee, Seung-Chul;Lee, Duck-Hee
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.16-22
    • /
    • 2012
  • In fire test, accurate heat release rate measurements provide important information to define the fire safety characteristics of products. The calculation of heat release rate depends on the errors of measuring parameters in experimental set-up. In this study, the uncertainty factors of heat release rate in the room corner test facility, which is installed at Korea Railroad Research Institute, were analyzed. Through the fire testings for the KTX interior materials, the uncertainties of heat release rate were calculated. Results showed that uncertainty was high in the initial stage of fire test and gradually decreased with the growth of fire. The oxygen concentration was a major factor contributing to the combined relative standard uncertainty.

The change in temperature·humidity·perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit (소방공무원의 방화복 착용 후 단계별 운동강도 변화 시 의복 내 온도·습도·발한량 차이)

  • Choi, Seo-Yeon;Park, Il-Gyu;Kong, Il-Chean;Rie, Dong-Ho
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.97-103
    • /
    • 2013
  • The purpose of this study was to verify the change in temperature humidity perspiration of fire suit when applying phased intensive exercises to fire fighter wearing fire suit. For this study, three male fire fighters took basic physical test and performed 10 minute phased intensive exercises -exercise intensity I (30%VO2max), exercise intensity II (45%VO2max), exercise intensity III (60%VO2max) based on maximum oxygen consumption (VO2max)- wearing fire suit (helmet, boots, air respirator) in treadmill and took a rest. The result of study shows that the temperature in the suit elevated during stabilization period after each exercise intensity, humidity elevated as exercise intensity increased, perspiration elevated as exercise intensity increased. This study indirectly ascertained the fire suit's physiological change in fire fighters during field activities.

A Study on Improvement of Professional Fire Investigation Education and Certification System (화재조사전문교육 및 자격증제도 개선에 관한 연구)

  • Ko, Gi-Bong;Lee, Si-Young
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.32-42
    • /
    • 2009
  • This study aims to analyze operation status of the professional fire investigation education in Korea and derive improvement measures. Study results showed that professional fire investigation educations are conducted mainly by public sectors (Fire Service, Police, Korea Electrical Safety Corp, Korea Gas Safety Corp, etc.) and the educations conducted by National Fire Service Academy are most systematic. In addition, there was no professional fire investigation educations conducted for private sector (fire accident suffers, common peoples, etc.) In order to improve the problems, this study suggests changing the National Fire Service Academy to lifelong education system in coordinance with the scholar's courses of universities, classifying the fire inspector qualification course (executed by National Emergency Management Agency) in five stages, and opening the fire inspector qualification test to the public.

Performance Evaluation Criteria for Safety Helmets of Forest Firefighting Crews (산불진화대원용 안전헬멧에 대한 성능평가 기준 연구)

  • Hong, Seung-Tae;Jeong, Jae-Han;Kim, Sung Yong;Kwon, ChunGeun
    • Fire Science and Engineering
    • /
    • v.33 no.5
    • /
    • pp.66-77
    • /
    • 2019
  • To secure the safety and improve the work efficiency of forest firefighting crews, performance evaluation criteria for safety helmets were developed in this study. Because the standards for forest firefighting safety helmets are not available in Korea, we began our study based on the standards for firefighting safety helmets used by the Korea Fire Institute (KFI). Eleven test items were selected excluding 15 other items out of the 26 test items that, through the consultation of stakeholders and the review of foreign standards, were initially included in our study. Two types of general safety helmets and one firefighting helmet were tested by applying KFI standards, and the results were compared. The general safety helmets did not meet the standards of the retention system and chin strap. Additionally, polyethylene and acrylonitrile butadiene styrene materials were found to be especially weak under heat conditions. We compared the criteria of KFI, International Standardization Organization (ISO) 16073, National Fire Prevention Association (NFPA) 1977, NFPA 1971, and British Standards European Norm (BS EN) 443, and finally selected 11 test items and their acceptance criteria suitable for the work environment of forest firefighting crews in Korea.

Development of an Inert Gas Water Mist System -A Numerical Study on Ventilation of the Fire Test Room- (불활성가스 미분무소화설비의 개발 -화재시험실의 급기에 관한 수치연구-)

  • Park, Woe-Chul;Jeong, Lee-Gyu
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.1
    • /
    • pp.25-30
    • /
    • 2008
  • A Numerical study was carried out for a propane gas pool fire in the fire test room of $2.5m{\times}2.0m{\times}2.5m$ for testing a inert gas water mist system, to investigate a possible under-ventilation in the fire test room. For the fire sizes of 60 kW and 120 kW, changes in the temperature and CO concentration with and without a window were investigated. It was confirmed that the influence of the window on the distributions of temperature and CO concentration was small in the two fire sizes, and hence the under-ventilation was not occurred in the room.

  • PDF