• Title/Summary/Keyword: Fire Risk

Search Result 1,141, Processing Time 0.028 seconds

Using Workers' Compensation Claims Data to Describe Nonfatal Injuries among Workers in Alaska

  • Lucas, Devin L.;Lee, Jennifer R.;Moller, Kyle M.;O'Connor, Mary B.;Syron, Laura N.;Watson, Joanna R.
    • Safety and Health at Work
    • /
    • v.11 no.2
    • /
    • pp.165-172
    • /
    • 2020
  • Background: To gain a better understanding of nonfatal injuries in Alaska, underutilized data sources such as workers' compensation claims must be analyzed. The purpose of the current study was to utilize workers' compensation claims data to estimate the risk of nonfatal, work-related injuries among occupations in Alaska, characterize injury patterns, and prioritize future research. Methods: A dataset with information on all submitted claims during 2014-2015 was provided for analysis. Claims were manually reviewed and coded. For inclusion in this study, claims had to represent incidents that resulted in a nonfatal acute traumatic injury, occurred in Alaska during 2014-2015, and were approved for compensation. Results: Construction workers had the highest number of injuries (2,220), but a rate lower than the overall rate (34 per 1,000 construction workers, compared to 40 per 1,000 workers overall). Fire fighters had the highest rate of injuries on the job, with 162 injuries per 1,000 workers, followed by law enforcement officers with 121 injuries per 1,000 workers. The most common types of injuries across all occupations were sprains/strains/tears, contusions, and lacerations. Conclusion: The successful use of Alaska workers' compensation data demonstrates that the information provided in the claims dataset is meaningful for epidemiologic research. The predominance of sprains, strains, and tears among all occupations in Alaska indicates that ergonomic interventions to prevent overexertion are needed. These findings will be used to promote and guide future injury prevention research and interventions.

Study on Recycling Technology of Waste Artificial Marble using Starch (전분을 이용한 폐인조대리석의 재활용 기술에 관한 연구)

  • Ryoo, Keon Sang
    • Journal of the Korean Chemical Society
    • /
    • v.62 no.6
    • /
    • pp.433-440
    • /
    • 2018
  • The pyrolysis has been universally applied to recycle the waste artificial marble. However, the existing heat treatment equipment has relatively low heat transfer efficiency into the inner part of the waste artificial marble. Besides, it leads to unnecessary excessive gas during the partial carbonization of the polymethyl methacrylate (PMMA) and raises the risk of fire due to heat at an extremely high temperature. This study suggests the process of pyrolysis at the formation state after adding the starch to waste artificial marble to overcome above-mentioned problems. As the result of experiments, this method showed that the pyrolysis of waste artificial marble was greatly improved at comparatively low temperature condition of $350^{\circ}C$. Moreover, it also manifested the effect on securing the stability and energy savings necessary for the recovery of methyl methacrylate (MMA) and ${\alpha}$-alumina (${\alpha}-Al_2O_3$).

Design of Gate Driver Chip for Ionizer Modules with Fault Detection Function (Fault Detection 기능을 갖는 이오나이저 모듈용 게이트 구동 칩 설계)

  • Jin, Hongzhou;Ha, PanBong;Kim, YoungHee
    • Journal of IKEEE
    • /
    • v.24 no.1
    • /
    • pp.132-139
    • /
    • 2020
  • The ionizer module used in this air cleaner supplies high voltages of 3.5KV / -4KV to the discharge electrode HV+ / HV- using a winding transformer to generate positive and negative ions by electric field radiation of carbon fiber brush. The ionizer module circuit using the existing MCU has the disadvantage of large PCB size and expensive price, and the gate driver chip using the existing ring oscillator has oscillation period sensitive to PVT (Process-Voltage-Temperature) fluctuation and there is risk of fire or electric shock because there is no fault detection function by short circuit of HV+ and GND as well as HV- and GND. Therefore, in this paper, even though PVT fluctuates, by using 7-bit binary up counter, HV+ voltage reaches the target voltage by adjusting oscillation period. And an HV+ short fault detection circuit for detecting a short circuit between HV+ and GND, an HV- short fault detection circuit for detecting a short circuit between HV- and GND, and an OVP (Over-Voltage Protection) for detecting that HV+ rises above an overvoltage are newly proposed.

Real-time Reagent Management System Using NFC / Sensor (NFC/센서를 이용한 실시간 시약 관리 시스템)

  • Kim, Ho-Sung;Jang, Jae-Myung;Jung, Hoe-Kyung
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.20 no.2
    • /
    • pp.421-426
    • /
    • 2016
  • Recent developments in internet technologies has enabled widespread growth of embedded systems like Arduino, Raspberry Pi and other smart home systems. A research in the industrial sector on the utilization of the board has been made. The development needs of the embedded board in a reagent bottle case system has been highlighted. Current reagent Management System has to hold and manage the reagent itself is mostly to save the program using handwritten or machine. In addition, there is a risk to the system during the vulnerable zone administrator to manage the situation of the reagent bottle case can lead to a massive fire. In this paper, reagent bottle case RFID readers and data in real-time is monitored by attaching a sensor management through the database and sends a warning message to the mobile device of the administrator in real time during hazardous situations in the reagent bottle case. This is improve the reliability and efficiency of reagent bottle case.

A Trends Analysis on Safety for CNG/HCNG Complex Fueling Station (CNG/HCNG 복합충전소의 안전에 관한 동향분석)

  • Lee, Seung-Hyun;Kang, Seung-Kyu;Sung, Jong-Gyu;Lee, Young-Soon
    • Journal of the Korean Institute of Gas
    • /
    • v.15 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • In this research, the safety trends and technologies of HCNG, a mixture of hydrogen and natural gas, are analyzed. This is an attracting alternative fuels to meet the strengthened automotive exhaust gas emission standards. HCNG is very important opportunities and challenges in that it is available the existing CNG infrastructures, meets the strengthened emission standards, and the technical, social bridge of the coming era of hydrogen. It is essential for the commercialization of HCNG that hydrogen - compressed natural gas blended fuel for use in preparation of various safety considerations included accidents scenario, safety distance, hydrogen attack, ignition sources and fire detectors are examined. Risk assessments also are suggested as one of permission procedure for HCNG filling station.

A Study on the Physical and Chemical Characteristics and Hazards Buthanethiol (Buthanethiol의 물리화학적 특성과 유해성 연구)

  • Kim, Hyeon-Yeong
    • Journal of the Korean Institute of Gas
    • /
    • v.17 no.4
    • /
    • pp.9-17
    • /
    • 2013
  • Butanethiol is known as a typical odorant with hydrogen sulfide, methyl mercaptan, methyl sulfide, but on the physical and chemical properties and biological hazard assessment, including inhalation toxicity data are very scarce. Butanethiol as a colorless transparent liquid, and has physic-chemical characteristics with flash point as $-23^{\circ}C$ and strong fire risk, boiling point $84-85^{\circ}C$, vapor pressure 80.71 mmHg ($25^{\circ}C$), freezing point $-140.14^{\circ}C$. From whole body exposure with SD rats, the $LC_{50}$ is above 2,500 ppm (9.22mg/L), and then it is classified as the acute toxic chemical (inhalation) category 4 according to the governmental notification No. 2012-14.

A Study on Performance Evaluation and Security Measures of U-IT Electrical Safety Integrated Management System's Module (U-IT 전기안전통합관리시스템의 모듈별 성능평가와 보안방법 연구)

  • Park, Dea-Woo;Choi, Choung-Moon;Kim, Eung-Sik
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2010.05a
    • /
    • pp.307-310
    • /
    • 2010
  • Ubiquitous society to build basic infrastructure in the power supply and power equipment safety is important. U-City in order to prevent the disaster of U-IT Power Equipment Performance Module and the security for the safety of the U-City is necessary. In this paper, the power unit of U-IT module, temperature sensor, humidity sensor, equipped with sensors arranged throughout the fire, and home distribution boards, Home Network Wall-Pad, Blocker, MPNP black boxes, arc detection, arc safety equipment, outlet of the modular performance evaluation and security measures will be studied. U-IT power devices and sensors to analyze the information conveyed by proactive risk and ensure safety, access control, authentication, security safeguards, such as U-IT integrated management system for electrical safety and strengthen the security, safety and security with a U-City will contribute to the construction and operation.

  • PDF

AE Characteristic under Tensile of Carbon Steel for High-Pressure Pipe (고압배관용 탄소강의 인장시 음향방출 특성)

  • Nam Kiwoo;Lee Siyoon
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.2 s.19
    • /
    • pp.48-53
    • /
    • 2003
  • This study is to look at the effect for deformation of carbon steel for high-presure pipe, on the AE signals produced by tensile test. Acoustic emission(AE) has been widely used in various fields because of its extreme sensitivity, dynamic detection ability and location of growing defects. We investigated a relationship failure mode and AE signals by tensile test, From the tensile test, we could divide into four ranges of the failure modes of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u. And failure behaviors of elastic range, yield range, plastic range before $\sigma$u, plastic range after $\sigma$u could be evaluated in tensile test by AE counts, accumulation counts and time frequency analysis. It is expected to be basic data that can protect a risk according to tensile test and bending of pipe material for pressure vessel, as a real time test of AE.

  • PDF

A Study on Development of Root Cause Analysis Map In Laboratory (연구 실험실 사고의 근본원인분석 Map 개발에 관한 연구)

  • Eom, Seok-Hwa;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.6-11
    • /
    • 2010
  • The continuous fatal accidents like explosion or fire cause huge losses of both life and property in laboratories even though safety management system has been built and periodical checkups and safety diagnosis have been implementing in universities and enterprise-affiliated research institutes since Act on the Establishment of Safe Laboratory Environment was enacted in 2005 to prevent accidents in research laboratories. Cause analysis and safety management measures to prevent recurrence of accidents are urgently needed because accidents in research laboratories occur repeatedly with similar contents. This study will show results of analysis on incidents and accidents occurred in laboratories in universities and enterprise-affiliated research institutes using Root Cause Analysis Method and propose classified map of cause investigation and improvements so as to improve safety management in research laboratories.

A Study on Analysis of Laboratory Accident with Root Cause Analysis (근본원인분석 기법을 활용한 실험실 사고 분석에 관한 연구)

  • Eom, Seok-Hwa;Lee, Su-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.14 no.4
    • /
    • pp.1-5
    • /
    • 2010
  • Many sorts of fatal accidents like explosion or fire caused by gas leakage have become a social issue with the increasing use of harmful chemicals in laboratories in universities and enterprise-affiliated research institutes in Korea. Importance of safety management has been emphasized and it made Act on the Establishment of Safe Laboratory Environment enacted not only to protect lives and bodies of people working in laboratories in universities and enterprise-affiliated research institutes but also to make pleasant experimental atmosphere. Safety management system has been built and periodical checkups and safety diagnosis have been implementing in universities and enterprise-affiliated research institutes to prevent such accidents. However, in spite of those actions, continuous accidents make analysis of root cause essential. This study will show results of analysis on incidents and accidents occurred in laboratories in universities and enterprise-affiliated research institutes using Root Cause Analysis Method and propose the direction of safety management.