• Title/Summary/Keyword: Fire Resistance Covering

Search Result 28, Processing Time 0.044 seconds

Behavior Characteristics of PCM Infilled Floor System at Elevated Temperature (고온에 노출된 PCM 충진형 바닥 시스템의 거동 특성)

  • Park, Min-Jae;Min, Jeong-Ki;Yoon, Sung-Won;Ju, Young K.
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.2
    • /
    • pp.33-41
    • /
    • 2017
  • Composite Floor system infilled with PCM(Phase Change Material) between upper and lower steel plates was developed to apply the steel frame. When steel frames were applied this system, it can absolutely reduce the duration of construction due to dry construction method. However to apply this system as a structural floor member without fire resistance covering, it must have 2 hours fire resistance performance. Because PCM consisted of three quarters of section with thermal insulation performance, fire resistance performance of this floor system was expected to easily have 2 hours fire resistance performance. This paper was to investigate behavior characteristics of PCM infilled floor system at elevated temperature using FEM analysis to develop the fire resistance performance of it.

The Experimental Study of Inorganic Performanent내s of Fire Resistance Evaluation (무기질계 영구거푸집의 내화성능에 관한 실험적 연구)

  • 김영진;백민수;정근호;김우재;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.10a
    • /
    • pp.495-500
    • /
    • 2002
  • The purpose of this study is to develop and to apply this permanent cement mortar form as one of those system forms to improve existing form's problems. (1) In the fire proof test with combined specimen, the fire proof covering including form section thickness is satisfied with the fire proof criterion. It is considered that form section thickness has no problem (2) The suitable method of normal pressure steam curing for the form's mass production is 4 hours in 65℃ considering production cost, the silica fume admixture is economic.

  • PDF

Study on the High Temperature Properties of Fireproof Mortar Using Various Types of Fine Aggregate (잔골재 종류에 따른 내화피복용 모르타르의 고온 성상에 관한 연구)

  • Lim, Seo-Hyung
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.2 no.2
    • /
    • pp.100-106
    • /
    • 2014
  • High strength concrete has a structural advantage as well as superior usability and durability, so that its application in building is being steadily augmented. However, in the high temperature like in a fire, the high strength concrete has extreme danger named explosive spalling. It is known that the major cause of explosive spalling is water vapour pressure inside concrete. General solution for preventing concrete from spalling include applying fire protection coats to concrete in order to control the rising temperature of members in case of fire. The purpose of this study is to investigate the high temperature properties of fireproof mortar using organic fiber and various types of fine aggregate for fire protection covering material. The results showed that addition of perlite and polypropylene fiber to mortar modifies its pore structure and reduces its density. This causes the internal temperature to rise. As a results, it is found that a new fireproof mortar can be used in the fire protection covering material in high strength concrete.

A study on the characteristic of fire protection covering for high strength concrete (고강도 콘크리트 내화피복 특성연구)

  • Song, Young-Chan;Lee, Sea-Hyun;Kim, Woo-Jae;Yang, Wan-Hee;Park, Dong-Cheol;Baik, Byung-Hoon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2006.11a
    • /
    • pp.429-432
    • /
    • 2006
  • In this study a board was made with good fireproof materials of which test was conducted according to the fireproof test for KS F 2257 construction members, and the temperature in coated steel which has a possibility to explode with concrete surface was measured. It is not appropriate to use normal mortar or mortar covering mixed with P.P. fiber to take a measure to prevent the explosive splalling of high-strength concrete. To finalize an Al-Si (aluminosilicates) board-requires over 30mm in thickness at the minimum for the required fire resistance performance and explosion prevention.

  • PDF

A Study on the Fire Resistance Performance of Wood Framed Lightweight Wall which Including a Middle Lintel (중인방을 포함한 목골조 경량벽체의 내화성능에 관한 연구)

  • Yeo, In-Hwan;Cho, Bum-Yean;Min, Byung-Yeol;Yoon, Myung-O
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.91-98
    • /
    • 2011
  • This study is about fire resistance performance of wood framed lightweight wall including a middle lintel as a traditional wall form in Korea. The target wall is non-loadbearing system which constructed with $38{\times}89$ mm ($2"{\times}4"$) wood frame and fireproof gypsum board covering, including a middle lintel made of $150{\times}150$ mm section glue-laminated timber. As a test results, all specimens have showed fire resistant performance over 90 minutes and tests were maintained until flame occuring on Specimen-l, 2, 3 at 91 min, 97 min and 98 min respectively. Fire resistance of the heat side gypsum board was 45 minutes and charring rate of middle lintel was equivalant with that of usual timber. The wood stud inside wall system showed relatively quick combution characteristic when exposed to high temperature with no temperature rising delaying time caused by moisture evaporation because of the dehydration preceded during the early period of fire side gypsum board resist to heat.

Countermeasure and Spalling Property of High Performance Concrete (고성능 콘크리트의 폭렬특성 및 대책)

  • Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.04a
    • /
    • pp.1105-1108
    • /
    • 2008
  • This paper investigated measures of spalling prevention and mechanism to secure stability of subjected to a fire circumstance. The results were summarized as following. 1) There were 4 kinds of methods for spalling prevention, such as declining percentage of water content and cement water ratio, isolating from high temperature with fire proof covering, giving lateral resistance stress, and discharging vapor pressure using fibers. 2) It was confirmed that methods using fibers to a new construction and fire proof covering to a existing construction on the basis of investigation for the spalling mechanism through the existing theory of spalling and a new theory of WPB.

  • PDF

Fire Resistance of High Strength Concrete followed by Thickness of Fireproof Plaster Board and Change of Adhesive Method (방화석고보드의 두께 및 접착방식 변화에 따른 고강도 콘크리트의 내화특성)

  • Jang, Ki-Hyun;Kim, Won-Ki;Jin, Hu-Lin;Lee, Jin-Woo;Yang, Seong-Hwan;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.05a
    • /
    • pp.67-71
    • /
    • 2008
  • The study analyzed on fire resistance of high strength concrete followed by thickness of fireproof plaster board and change of adhesive method. In spalling characteristics after fire resistance test, all four-side covering concretes were left out of testing screens. Thus, serious spalling was happened by exposing their internal reinforcing rods. in partial testing screens, spalling was happened till the internal concrete of main reinforcing rod. Only, temperature history didn't have special differences among changes of adhesive method. However, thickness of fireproof plaster board is very important. Namely, mock member reinforcing 25mm general adhesive + Bending was 583℃ in the highest temperature of surface part and 479℃ in the highest temperature of the main reinforcing rod, which was relatively good temperature history.

  • PDF

A Study on the Development Composite Fireproof Board Type for Fire Resistance Improvement of High Strength Concrete One Side Simplicity Heating Furnace Type - One Side Simplicity Heating Furnace Type - (고강도 콘크리트의 내화성능향상을 위한 합성내화보드 개발에 관한 연구 - 1 면 간이가열로 방식 -)

  • Shin, Jae-Kyung;Choi, Jin-Man;Lee, Sung-Chan;Moon, Hyung-Jae;Kim, Jeong-Jin;Park, Soon-Jeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2009.05a
    • /
    • pp.233-234
    • /
    • 2009
  • This study investigates the possibility of development of composite fireproof board type that is to improve the resistance of fireproof material and the problem of a conventional fire proof covering methods to prevent spalling failure of high strength concrete members.

  • PDF

A Study on Relations between Shape Factor and Temperature History of Steel of Composit Beam in Standard Fire under Same Thickness Condition of Spray-type Fire Resistant Materials (동일 내화뿜칠 피복조건에서 표준화재에 노출된 합성보의 강재 온도이력 및 단면형상계수와의 관계)

  • Yeo, In-Hwan;Cho, Kyung-Suk;Cho, Bum-Yean
    • Fire Science and Engineering
    • /
    • v.26 no.6
    • /
    • pp.72-77
    • /
    • 2012
  • When the concrete and steel combined composite beam is exposed to high temperature, concrete could delay temperature rising of steel by covering or increase heat capacity of structural member. For becoming of structural reinforcing by unification between materials, fire resistance rate of composite beam would be higher than simple steel beam. The temperature rising of exposed steel of composite beam is directly related with section shape and exposure length of steel. In this study, fire resistant tests were carried out for composite beams and steel beam with same thickness of spray-type fire resistant materials in standard fire, and after that, temperature histories were analysed and compared with shape factor. The correlation between steel temperature and shape factor was showed very high. This result suggests that if it can be predict the comparative advantage of member by factor which cause the performance enhancement, it could be conclude that an Standard Accreditation method can be adjust to members without indivisual certifiicate of accreditation.