• Title/Summary/Keyword: Fire Reduction Program

Search Result 24, Processing Time 0.024 seconds

Current Status of Fire Reduction Policy and Its Policy Impressions (화재저감정책의 현황과 개선과제)

  • Jo, Kwang-Hee;Kim, Sung-Il;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.3
    • /
    • pp.19-25
    • /
    • 2017
  • To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved.

A Study on the Development of Performance Based Fire Risk Assesment Program (FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구)

  • Rie, Dong-Ho
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

A Study on the Evacuation Time by the Influence of Decreasing Visibility on Fire (화재시 가시도 변화에 따른 대피속도 산정에 관한 연구)

  • Rie, Dong-Ho;Park, Jong-Seung
    • Journal of the Korean Society of Safety
    • /
    • v.22 no.5
    • /
    • pp.21-26
    • /
    • 2007
  • The computer program is developed to simulate the evacauation time for a building which is made geometrically complex. The program is intended for use both as a search and a design tool to analyze the evacuation safety through a wide range of structure environments. The computer program has a function of importing FDS's result to each individual resident in the building. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments to individual speeds due to the proximity of crowd members. Finally, a case study for a theater is presented to compared the calculated evacuation time with SIMULEX in detail. This program contribute to a computer program that evaluates the evacuation time of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

Copper-Based Compounds against Erwinia amylovora: Response Parameter Analysis and Suppression of Fire Blight in Apple

  • Duck Kyu, Ryu;Mahesh, Adhikari;Dong Hyuk, Choi;Kyung Jin, Jun;Do Hyoung, Kim;Chae Ryeong, Kim;Min Kyu, Kang;Duck Hwan, Park
    • The Plant Pathology Journal
    • /
    • v.39 no.1
    • /
    • pp.52-61
    • /
    • 2023
  • Fire blight, caused by Erwinia amylovora, is one of the major bacterial disease of apple and pear, causing enormous economic losses worldwide. Several control measures against E. amylovora have been reported till date, however, none of them have proved to be effective significantly against the pathogen. In this study, mechanisms of the copper-based control agents (CBCAs): copper oxychloride (COCHL), copper oxide (COX), copper hydroxide (CHY), copper sulfate basic (CSB), and tribasic copper sulfate (TCS) and their disease severity reduction efficacy against E. amylovora were analyzed. Bis-1,3-dibutylbarbituric acid trimethine oxonol, carboxyl fluorescein diacetate succinimidyl ester, and 5-cyano-2,3-ditolyl tetrazolium chloride staining were used to check the damage of membrane potential, cytoplasmic pHin, and respiration of CBCAs-treated E. amylovora, respectively. High disturbance in the membrane potential of E. amylovora was found under COX and COCHL treatments. Similarly, higher significant changes in the inner cytoplasmic pHin were observed under COX, COCHL, and TCS treatment. CHY and COCHL-treated E. amylovora showed a significant reduction in respiration. In vitro bioassay results revealed that CHY, CSB, and TCS at 2,000 ppm reduced the severity of fire blight both in pre- and post-treatment of CBCAs in immature apple fruits and seedlings. Overall, the most effective CBCAs against E. amylovora could be CHY at 2,000 ppm as its showed inhibition mechanisms and disease severity reduction.

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2006.04a
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System (가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발)

  • So, Soo-Hyun;Oh, Ju-Hwan;Cha, Cheol-Woong;Lee, Dae-Kuen
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

Thermo-mechanical compression tests on steel-reinforced concrete-filled steel tubular stub columns with high performance materials

  • David Medall;Carmen Ibanez;Ana Espinos;Manuel L. Romero
    • Steel and Composite Structures
    • /
    • v.49 no.5
    • /
    • pp.533-546
    • /
    • 2023
  • Cost-effective solutions provided by composite construction are gaining popularity which, in turn, promotes the appearance on the market of new types of composite sections that allow not only to take advantage of the synergy of steel and concrete working together at room temperature, but also to improve their behaviour at high temperatures. When combined with high performance materials, significant load-bearing capacities can be achieved even with reduced cross-sectional dimensions. Steel-reinforced concrete-filled steel tubular (SR-CFST) columns are one of these innovative composite sections, where an open steel profile is embedded into a CFST section. Besides the renowned benefits of these typologies at room temperature, the fire protection offered by the surrounding concrete to the inner steel profile, gives them an enhanced fire performance which delays its loss of mechanical capacity in a fire scenario. The experimental evidence on the fire behaviour of SR-CFST columns is still scarce, particularly when combined with high performance materials. However, it is being much needed for the development of specific design provisions that consider the use of the inner steel profile in CFST columns. In this work, a new experimental program on the thermo-mechanical behaviour of SR-CFST columns is presented to extend the available experimental database. Ten SR-CFST stub columns, with circular and square geometries, combining high strength steel and concrete were tested. It was seen that the circular specimens reached higher failure times than the square columns, with the failure time increasing both when high strength steel was used at the embedded steel profile and high strength concrete was used as infill. Finally, different proposals for the reduction coefficients of high performance materials were assessed in the prediction of the cross-sectional fire resistance of the SR-CFST columns.

Effects of Forest Therapy Program on Stress levels and Mood State in Fire Fighters (산림치유프로그램이 소방공무원의 외상 후 스트레스 및 기분상태 변화에 미치는 효과)

  • Park, Choong-Hee;Kang, Jaewoo;An, Miyoung;Park, SuJin
    • Fire Science and Engineering
    • /
    • v.33 no.6
    • /
    • pp.132-141
    • /
    • 2019
  • This study was conducted to investigate the effects of a forest therapy program on post-traumatic stress disorder (PTSD) and mood states of fire fighters. A total of 293 participants completed two psychological questionnaires before and after the program was conducted: the Post Traumatic Stress Disorder Checklist (PCL) and the Profile of Mood States (POMS). Data were analyzed with paired t-test and ANCOVA using SPSS 24.0. The PTSD results showed a significant decrease from 11.38 ± 12.58 points before the program to 6.91 ± 10.50 points after the program. Results of the POMS questionnaire revealed an increase in positive factors and a decrease in negative factors, with a significant overall decrease in POMS results from 8.58 ± 18.47 points before the program to -0.63 ± 15.83 points after the program. As a result of analyzing the differences in stress reduction effects according to the amount of sleep participants had, PTSD showed improvement at 6-8 hours of sleep. These results are expected to be utilized as a basis for stress management and relief in fire fighters.

A Study on Searching for Reduction of Women EMTs's Stress (여성 구급대원의 현장 스트레스 경감방안 모색에 관한 연구)

  • Kong, Ha-Sung;Lee, Ranny;Lee, Seong-Chul
    • Journal of the Korea Safety Management & Science
    • /
    • v.15 no.4
    • /
    • pp.113-121
    • /
    • 2013
  • The rate that women's EMTs(emergency medical technicians) in fire department occupy is increasing, but my general plan is aimed at suggesting the improving plan for the working environment of women's EMTs paying attention to the duty stresses of increasing women's EMTs, because improvement for the working environment of women's EMTs is being proceeded slowly. I suggested my improving plan for solving the working stress on the basis of a survey of the Recognition against women's EMTs as follows. Firstly, I suggested that physical strength of women's EMTs should be managed well continually via program establishment and a defined evaluation not only by employing a professional person in charge for physical strength in firehouse, but also by replenishing the suitable number for the urgent mobilization. Secondly, I suggested that the suitable number for the urgent mobilization should be increased to 3 including an ambulance driver. Thirdly, I suggested necessity such as the fruitful education and the creation of circumstances that can focus on education for improving participation rate, development of various new educational program, incentive program and penalty. finally, I suggested the fact that is related to the actual re-amendment of the concerned law and ordinance such as not only the smooth treatment of penalty for a traffic signal violation of ambulance and the legal remedy system due to aggravation of a patient's condition during a first-aid course, but also workshop and meeting among the periodical EMTs and administration of special therapy program and sufficient recess.

A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection (소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구)

  • Mun, Chul-Hwan;Kang, Ho-Jung;Choi, Jae-Wook
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.69-77
    • /
    • 2020
  • With the recent enlargement and complication of buildings, damage caused by the incidents of fires breaking out are escalating. Consequently, the use of sprinkler facilities is increasing among water-based fire extinguishing systems. Piping materials used in fire prevention systems include carbon steel (for general or pressure pipeline), CPVC, copper, and stainless-steel. Among these, the steel and CPVC pipes, which are commonly employed in fire prevention, were considered for testing the reliability of the water-based systems. This analysis was performed using the PIPENET software to perform hydraulic calculations in order to examine the flow and pressure at the terminal head when the corrosion coefficient was applied; this coefficient was applied considering the aging of pipes. Assuming a uniform pipe diameter in the steel pipes, the rated flow in the pump installed on the first floor of the basement was reduced by over 10% after 20 years had passed (C value of 90); moreover, the reduction in pressure and flow at its terminal head exceeded 30% and 16.5%, respectively. The results indicate that it is difficult to ensure the reliability of these fire prevention facilities. Furthermore, according to our estimation, considering 30 years had passed (C value of 80), the rated flow of the pump was reduced by over 15%, and the corresponding reduction in pressure and flow at its terminal head exceeded 42% and 24%, respectively.