• 제목/요약/키워드: Fire Reduction Program

검색결과 24건 처리시간 0.03초

화재저감정책의 현황과 개선과제 (Current Status of Fire Reduction Policy and Its Policy Impressions)

  • 조광희;김성일;강경식
    • 대한안전경영과학회지
    • /
    • 제19권3호
    • /
    • pp.19-25
    • /
    • 2017
  • To minimize and prevent the increasing fire and personal injury, the domestic firefighting organizations are making continuous efforts to strengthen the response system and safety standards. "Fire Reduction Program" has been prepared to reduce the outbreak of fire up to 20% in the next 10 years, and the analysis of fire sources should be done and its countermeasures also should be done accordingly. Therefore, the management status, the improvement tasks, and the limitations of the implementation plan are reviewed and studied so that the implementation and goal of the "Fire Reduction Policy" can be achieved.

FDS를 활용한 성능위주 화재위험성평가 프로그램개발에 관한 연구 (A Study on the Development of Performance Based Fire Risk Assesment Program)

  • 이동호
    • 한국안전학회지
    • /
    • 제23권5호
    • /
    • pp.1-6
    • /
    • 2008
  • `SOS', Simulator Of Safety assessment for fire, was developed to simulate fire safety assessment for a structure which is geometrically complex. The program(SOS) is intended to use for searching as well as designing tools to analyse the evacuation safety through a wide range of structure conditions. The computer program has a function which importing FDS's calculating results to each individual resident in the structure. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments individual speeds in accordance with the proximity of crowd members. This SOS program contributes to a computer package that evaluates the fire safety assessment of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

화재시 가시도 변화에 따른 대피속도 산정에 관한 연구 (A Study on the Evacuation Time by the Influence of Decreasing Visibility on Fire)

  • 이동호;박종승
    • 한국안전학회지
    • /
    • 제22권5호
    • /
    • pp.21-26
    • /
    • 2007
  • The computer program is developed to simulate the evacauation time for a building which is made geometrically complex. The program is intended for use both as a search and a design tool to analyze the evacuation safety through a wide range of structure environments. The computer program has a function of importing FDS's result to each individual resident in the building. These attributes include a walking speed reduction by producing visibility reduction for each person on the fire. $A^*$ pathfinding algorithm is adopted to calculate the simulation of escape movement, overtaking, route deviation, and adjustments to individual speeds due to the proximity of crowd members. Finally, a case study for a theater is presented to compared the calculated evacuation time with SIMULEX in detail. This program contribute to a computer program that evaluates the evacuation time of individual occupants as they walk towards, and through the exits especially for building, underground spaces like a subway or tunnel.

Copper-Based Compounds against Erwinia amylovora: Response Parameter Analysis and Suppression of Fire Blight in Apple

  • Duck Kyu, Ryu;Mahesh, Adhikari;Dong Hyuk, Choi;Kyung Jin, Jun;Do Hyoung, Kim;Chae Ryeong, Kim;Min Kyu, Kang;Duck Hwan, Park
    • The Plant Pathology Journal
    • /
    • 제39권1호
    • /
    • pp.52-61
    • /
    • 2023
  • Fire blight, caused by Erwinia amylovora, is one of the major bacterial disease of apple and pear, causing enormous economic losses worldwide. Several control measures against E. amylovora have been reported till date, however, none of them have proved to be effective significantly against the pathogen. In this study, mechanisms of the copper-based control agents (CBCAs): copper oxychloride (COCHL), copper oxide (COX), copper hydroxide (CHY), copper sulfate basic (CSB), and tribasic copper sulfate (TCS) and their disease severity reduction efficacy against E. amylovora were analyzed. Bis-1,3-dibutylbarbituric acid trimethine oxonol, carboxyl fluorescein diacetate succinimidyl ester, and 5-cyano-2,3-ditolyl tetrazolium chloride staining were used to check the damage of membrane potential, cytoplasmic pHin, and respiration of CBCAs-treated E. amylovora, respectively. High disturbance in the membrane potential of E. amylovora was found under COX and COCHL treatments. Similarly, higher significant changes in the inner cytoplasmic pHin were observed under COX, COCHL, and TCS treatment. CHY and COCHL-treated E. amylovora showed a significant reduction in respiration. In vitro bioassay results revealed that CHY, CSB, and TCS at 2,000 ppm reduced the severity of fire blight both in pre- and post-treatment of CBCAs in immature apple fruits and seedlings. Overall, the most effective CBCAs against E. amylovora could be CHY at 2,000 ppm as its showed inhibition mechanisms and disease severity reduction.

How to Reduce Fire Fatalities in Residential Occupancies on the Way to a Rapidly Aging Society?

  • Sekizawa, Ai
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2006년도 춘계학술논문발표회 논문집
    • /
    • pp.29-40
    • /
    • 2006
  • Everybody may be vulnerable to fires depending on the time, place, and circumstances. Fire statistics show that the occurrence of fire death depends not only on the severity of a fire itself, but also largely on the conditions of occupants such as physical functions, the environment around occupants, and the type of facility where are fire occurs. The review of fire safety from the viewpoint of vulnerable populations does not simply mean additional special attention and care only to high risk groups, but instead it means significant review of fire safety design and systems for all people from a more universal standpoint. Therefore, in order to examine the strategies of a fire death-reduction program, safety measures suitable for the relevant high-risk groups considering the type of vulnerable person, the type of fire, and the type of building in residential occupancies. Solutions will require strenuous multilateral effort and flexibility.

  • PDF

가스계 소화시스템용 소화약제 저장용기 누설 검출 무선 시스템 개발 (Development of Monitoring RF System on Leakage of Gas Cylinder in Gaseous Fire Extinguishing System)

  • 소수현;오주환;차철웅;이대근
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.7-10
    • /
    • 2008
  • In our study, Monitoring RF System in real-time on leakage of gas cylinder is developed. The system is consisted of Pressure Transmitting part, Main Controller and Operating program. The pressure data of gas cylinder are transmitted to the modem of main controller part by RF module of Pressure Transmitting part and the data received through the modem are recorded in real-time and showed the situation of gas cylinder on the PC monitor. Through the test on the case of the artificial pressure-reduction, the detecting performance. of the developed system is conformed.

  • PDF

Thermo-mechanical compression tests on steel-reinforced concrete-filled steel tubular stub columns with high performance materials

  • David Medall;Carmen Ibanez;Ana Espinos;Manuel L. Romero
    • Steel and Composite Structures
    • /
    • 제49권5호
    • /
    • pp.533-546
    • /
    • 2023
  • Cost-effective solutions provided by composite construction are gaining popularity which, in turn, promotes the appearance on the market of new types of composite sections that allow not only to take advantage of the synergy of steel and concrete working together at room temperature, but also to improve their behaviour at high temperatures. When combined with high performance materials, significant load-bearing capacities can be achieved even with reduced cross-sectional dimensions. Steel-reinforced concrete-filled steel tubular (SR-CFST) columns are one of these innovative composite sections, where an open steel profile is embedded into a CFST section. Besides the renowned benefits of these typologies at room temperature, the fire protection offered by the surrounding concrete to the inner steel profile, gives them an enhanced fire performance which delays its loss of mechanical capacity in a fire scenario. The experimental evidence on the fire behaviour of SR-CFST columns is still scarce, particularly when combined with high performance materials. However, it is being much needed for the development of specific design provisions that consider the use of the inner steel profile in CFST columns. In this work, a new experimental program on the thermo-mechanical behaviour of SR-CFST columns is presented to extend the available experimental database. Ten SR-CFST stub columns, with circular and square geometries, combining high strength steel and concrete were tested. It was seen that the circular specimens reached higher failure times than the square columns, with the failure time increasing both when high strength steel was used at the embedded steel profile and high strength concrete was used as infill. Finally, different proposals for the reduction coefficients of high performance materials were assessed in the prediction of the cross-sectional fire resistance of the SR-CFST columns.

산림치유프로그램이 소방공무원의 외상 후 스트레스 및 기분상태 변화에 미치는 효과 (Effects of Forest Therapy Program on Stress levels and Mood State in Fire Fighters)

  • 박충희;강재우;안미영;박수진
    • 한국화재소방학회논문지
    • /
    • 제33권6호
    • /
    • pp.132-141
    • /
    • 2019
  • 본 연구는 국립산림치유원에서 실시한 4박 5일형 산림치유프로그램이 소방공무원의 외상 후 스트레스 및 기분상태 변화에 미치는 효과를 알아보고자 수행되었다. 소방공무원 293명을 대상으로 설문조사를 실시하였으며, SPSS 24.0을 활용하여 빈도분석, 대응 t-검정 및 공분산분석을 실시하였다. 산림치유프로그램 참여 전과 후의 외상 후 스트레스, 기분상태의 차이 및 인구학적 특성에 따른 차이를 분석하였다. 외상 후 스트레스 결과, 참여 전 평균 11.38 ± 12.58점에서 참여 후 6.91 ± 10.50점으로 감소하여 통계적으로 유의한 영향을 미치는 것으로 나타났다. 기분상태검사 결과, 긍정적 요인은 증가하였고, 부정적 요인은 감소하였다. 전체 기분상태 또한 프로그램 참여 전 8.58 ± 18.47점에서 참여 후 -0.63 ± 15.83점으로 통계적으로 유의한 영향을 미치는 것으로 나타났다. 수면시간에 따른 스트레스 저감 효과 차이 분석 결과, 외상 후 스트레스는 수면시간이 6~8시간일 때 효과가 높게 나타났다. 본 연구결과는 소방공무원의 외상 후 스트레스 관리와 해소를 위한 방법이 될 수 있는 근거자료로 활용되기를 기대한다.

여성 구급대원의 현장 스트레스 경감방안 모색에 관한 연구 (A Study on Searching for Reduction of Women EMTs's Stress)

  • 공하성;이란희;이성철
    • 대한안전경영과학회지
    • /
    • 제15권4호
    • /
    • pp.113-121
    • /
    • 2013
  • The rate that women's EMTs(emergency medical technicians) in fire department occupy is increasing, but my general plan is aimed at suggesting the improving plan for the working environment of women's EMTs paying attention to the duty stresses of increasing women's EMTs, because improvement for the working environment of women's EMTs is being proceeded slowly. I suggested my improving plan for solving the working stress on the basis of a survey of the Recognition against women's EMTs as follows. Firstly, I suggested that physical strength of women's EMTs should be managed well continually via program establishment and a defined evaluation not only by employing a professional person in charge for physical strength in firehouse, but also by replenishing the suitable number for the urgent mobilization. Secondly, I suggested that the suitable number for the urgent mobilization should be increased to 3 including an ambulance driver. Thirdly, I suggested necessity such as the fruitful education and the creation of circumstances that can focus on education for improving participation rate, development of various new educational program, incentive program and penalty. finally, I suggested the fact that is related to the actual re-amendment of the concerned law and ordinance such as not only the smooth treatment of penalty for a traffic signal violation of ambulance and the legal remedy system due to aggravation of a patient's condition during a first-aid course, but also workshop and meeting among the periodical EMTs and administration of special therapy program and sufficient recess.

소방용 강관배관 부식계수를 고려한 수리계산 적용방안에 관한 연구 (A Study on the Application of Hydraulic Calculations considering the Corrosion Coefficient of Steel Piping for Fire Protection)

  • 문철환;강호정;최재욱
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.69-77
    • /
    • 2020
  • 최근 건축물의 대형화, 복잡화로 인하여 화재 발생 시 그 피해가 증가하고 있어 수계소화설비에서 스프링클러설비의 중요성이 확대되고 있다. 소방용 배관재로는 탄소강관(일반배관용·압력배관용), CPVC관, 동관, 스테인리스강관 등이 있으며, 소방용 배관으로 널리 사용되고 있는 강관배관 및 CPVC관에 대하여 배관의 노화를 고려한 부식계수 적용 시 말단헤드에서의 유량과 압력을 분석하기 위해 PIPENET 수리계산프로그램을 사용하여 수계시스템의 신뢰성을 분석하였다. 강관을 적용하였을 경우 배관 구경이 동일한 조건에서 20년경과(C값 90)후 지하 1층에 설치된 펌프에서의 정격유량은 10% 이상 감소하였으며, 말단헤드에서의 압력과 유량은 각각 30%, 16.5% 이상 감소하여 소방시설의 신뢰성 확보에 문제가 있는 것으로 확인되었다. 또한 30년(C값 80) 경과 시 펌프에서의 정격유량은 15% 이상 감소하였으며, 말단헤드에서의 압력과 유량은 각각 42%, 24% 이상 감소하는 것으로 결과 값이 도출되었다.