• Title/Summary/Keyword: Fire Policy

Search Result 238, Processing Time 0.025 seconds

A Study on the Fire Design Business Development Direction (소방시설설계업의 발전방향에 관한 연구)

  • Hong, Sung-Woo;Lee, Young-Jae;Park, Hung-Joo
    • Fire Science and Engineering
    • /
    • v.23 no.4
    • /
    • pp.67-72
    • /
    • 2009
  • For the fire-fighting industry to advance, it is necessary to conduct research on which parts of the fire-fighting law should be changed from the system level, and to study the opinions of the fire-fighters whoa re working in the fire-fighting industry today, and to identify what needs to be changed. Moreover, it is necessary to become aware on the preventive measures to take to avoid fire so that the citizens can lead stable life. Design business among the fire-fighting facility business, it is the fire-fighting facility business that serves as the most basic when constructing building structure. This is an important legal matter that follows the fire-fighting business, fire-fighting audit business and even the maintenance and management business. This research sought to help the fire-fighting industry to contribute to the life of the general public and to increase welfare by identifying the problems pertaining to the fire-fighting facility design business among the fire-fighting industry so that the industry can become the fire-fighting industry that the citizens are interested in. Moreover, direction for advancement is proposed. As for the improvement measures for the fire-fighting policy pertaining to the fire-fighting facility design business, it is divided into the machinery and electricity fields in terms of the legal system pertaining to the general fire-fighting facility design business. Likewise, specialty in design is deficient. Thus, it should be integrated in a systematic level to contribute to the safety of the general public.

A Study on an Improvement of the Fire-Protection System Category under the Enforcement of Housing Performance Rating System (주택 성능등급 표시제도 시행에 따른 소방시설 항목 개선에 관한 연구)

  • Lee, Su-Kyung;Lee, Dong-Yong;Hong, Dae-Hwa
    • Fire Science and Engineering
    • /
    • v.24 no.2
    • /
    • pp.126-132
    • /
    • 2010
  • The Housing Performance Rating System, enacted on 9 January 2006, an active measure containing provisions on improved quality and advanced performance of the Fire-Protection System for equalized ability to secure safety of life to some extent, is a desirable policy in fire-safety regard. The study of theoretical background of each performance rating section for the purpose of active and wide application of The Fire-Protection System category of the Housing Performance Rating System currently in effect internally. In accordance with the result of the study, the reform measures for the currently detailed evaluation criteria have been suggested to improve the performance of the Fire-Protection area of The Housing Performance Rating System currently being in force based on the assumption of prior settlement of the following; upward settlement of the point distribution standards on the performance ratings of each head backed up by an institutional Government policy with overriding priority; and urgently enacted Fire-Protection related laws and regulations.

The Analysis of Questionnaires About the investigation of fire and the task of fire fighting(Conducted chiefly by Fire Fighting employees of Kyonggi Province) (화재조사.진압임무 수행에 관한 설문조사 분석(경기도 소방공무원을 중심으로))

  • Gwon, Hyeon-Seok;Lee, Jae-Dong;Yun, Hyeok-Jung;Park, Gi-Hun
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.3 no.1
    • /
    • pp.16-32
    • /
    • 2003
  • Today, fires are becoming so catastrophic and complicated due to the industrialization and diversification of energy sources that it is getting more difficult to define the survey items in order to find out the causes and processes of the fire. As an organization of prevention, vigilance and putting out of the fire, Fire Fighting authorities are ultimately pursuing the system of fire fighting administration to protect human lives and their properties through establishment and performance of fire prevention policy based on the fire-related statistics they have gathered and prevention of future fires of the kind which can promote the safety of structural space. Thus, to facilitate the fire detection, it can be said that good understanding of the tasks of both investigation and putting out of the fire as being two axes has the greatest significance. For this study, textbooks from the organization of fire fighting and police, which are designed for the literature study on the investigation and putting out of fire, are used and for the demonstrative study, the conclusions have been reached by the analyses of the 64 questionnaires of three parts which were divided by fire investigation and fighting for three hundred and six governmental employees engaging in the above fields.

  • PDF

Development of User-centered Fire Safety Evaluation Model for School Buildings (교육시설의 사용자 중심 화재안전수준 평가모형 개발)

  • Park, Sung-Chul;Kim, Jin-Wook
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.238-239
    • /
    • 2021
  • This study presented the development of a user centered school facility fire safety evaluation model that would support fire safety evaluation, which is globally recognized as being important in terms of school safety, to be more efficiently implemented in the school field mainly by students. The study consisted of five steps. First, actual condition survey tools were developed based on the major fire safety evaluation items derived through literature review. Second, the characteristics of domestic school facilities in terms of fire safety were developed using the survey tools. Third, an evaluation model at a level utilizable by students was developed based on the foregoing characteristics. Fourth, the applicability of the model was verified through a trial application of the model to elementary school students. Finally, legal and institutional improvement plans and fire safety education materials were presented through a policy proposal.

  • PDF

The Leakage Crack Calculation of the Fire Door and the Stack Effect Analysis (방화문의 누설틈새 계산 및 연돌효과 분석)

  • Kim, Il-Young;Kwon, Chang-Hee
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.46-53
    • /
    • 2013
  • The architecture environment has changed. The corresponding design criteria should be changed. From July 27th, 2005 the Korea Standard of the fire door changed concerning the smoke resistance test which made the door gap structure more elaborate. However the National Fire Safety Codes are applied by the old data's of England. Which in case differs in the actual construction to the blue print, making the safety standard too excessive. Analyze the results and the phenomenon that occurs due to the difference between design and reality. The National Fire Safety Codes should be revised to leakage crack calculation is presented. Difference of the air flow for the smoke protection due to the stack effect analyzed. Living patterns and evacuation patterns of the apartment reflect and reasonable air flow measurement method are presented.

A Study on the Fire Risk Assessment of EIFS by Cone Calorimeter Test & Single Burning Item Test (중소형화재실험을 이용한 외단열 시스템(EIFS) 화재위험성평가에 관한 연구)

  • Min, Se-Hong;Kim, Mi-Suk
    • Journal of the Korea Safety Management & Science
    • /
    • v.12 no.1
    • /
    • pp.1-9
    • /
    • 2010
  • Recently, in circumstantial situation it is recommended positively to utilize of EIFS(Exterior Insulating and Finishing System) as energy policy for economizing energy. But internal EPS insulators of EIFS are exterior panel of high fire risk, because of constituting of flammable materials to be fragile in fire. In this study, fire risk is assessed by experiment Con Calorimeter test and SBI(Single Burning Item) test. As the result of experiment, Con Calorimeter tests do not reach to capability standard of internal incombustible grade, and are assessed as low grade in SBI incombustible grade. Because EIPS is exterior material in buildings with high fire risk in spite of good efficiency, it is required rapidly to take measures to meet situation through various studies(for instance, adjusting law regulation, etc.) in the future.

Application of reinforcement learning to fire suppression system of an autonomous ship in irregular waves

  • Lee, Eun-Joo;Ruy, Won-Sun;Seo, Jeonghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.12 no.1
    • /
    • pp.910-917
    • /
    • 2020
  • In fire suppression, continuous delivery of water or foam to the fire source is essential. The present study concerns fire suppression in a ship under sea condition, by introducing reinforcement learning technique to aiming of fire extinguishing nozzle, which works in a ship compartment with six degrees of freedom movement by irregular waves. The physical modeling of the water jet and compartment motion was provided using Unity 3D engine. In the reinforcement learning, the change of the nozzle angle during the scenario was set as the action, while the reward is proportional to the ratio of the water particle delivered to the fire source area. The optimal control of nozzle aiming for continuous delivery of water jet could be derived. Various algorithms of reinforcement learning were tested to select the optimal one, the proximal policy optimization.

Impact of Fire Demand on Fire Service Budget (소방수요가 소방예산에 미치는 영향)

  • Lee, Wonjoo;Lim, Jae Hoon;Moon, Kwang Min
    • Fire Science and Engineering
    • /
    • v.34 no.4
    • /
    • pp.125-134
    • /
    • 2020
  • This paper aimed to statistically analyze the impact of fire needs not considered in previous reports based on preventive and preparedness strategies of fire administration and fire budget.. The panel data came from 16 metropolitan councils from 2008 to 2018 and was statistically analyzed based on the preventive measures of the fire administration (agreement for building permission, specific target for fire-fighting, public use facilities, and special fire inspection [SFI]), preparedness of the fire administration (fire safety education [FSE]), response of the fire administration (mobilization for fire suppression [MFS] and mobilization for ambulance service [MAS]), and fire budget. In the results, SFI, FSE, and MFS had a significant negative influence on the fire budget. Meanwhile, MAS had a significant positive effect on the fire budget (p < 0.01). These results reflect public policy in Korea; there has been a paradigm shift in fire administration: from disaster acceptance (focusing on recovery) to disaster response (focusing on field response) to disaster preparedness (focusing on preparedness).

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.